• Title/Summary/Keyword: Seismic intensity

Search Result 331, Processing Time 0.022 seconds

Seismic fragility analysis of RC frame-core wall buildings under the combined vertical and horizontal ground motions

  • Taslimi, Arsam;Tehranizadeh, Mohsen;Shamlu, Mohammadreza
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • This study strives to highlight the importance of considering the vertical ground motions (VGM) in the seismic evaluation of RC buildings. To this aim, IDA (Incremental Dynamic Analysis) is conducted on three code-based designed high-rise RC frame-core wall buildings using a suite of earthquake records comprising of significant VGMs. To unravel the significance of the VGM inclusion on the performance of the buildings, IDAs are conducted in two states (with and without the vertical component), and subsequently based on each analysis, fragility curves are developed. Non-simulated collapse criteria are used to determine the collapse state drift ratio and the area under the velocity spectrum (SIm) is taken into account as the intensity measure. The outcome of this study delineates that the inclusion of VGM leads to the increase in the collapse vulnerability of the structures as well as to the change in the pattern of inter-story drifts and failure mode of the buildings. The results suggested that it would be more conservative if the VGM is included in the seismic assessment and the fragility analysis of RC buildings.

Probabilistic earthquake risk consideration of existing precast industrial buildings through loss curves

  • Ali Yesilyurt;Seyhan O. Akcan;Oguzhan Cetindemir;A. Can Zulfikar
    • Geomechanics and Engineering
    • /
    • v.37 no.6
    • /
    • pp.565-576
    • /
    • 2024
  • In this study, the earthquake risk assessment of single-story RC precast buildings in Turkey was carried out using loss curves. In this regard, Kocaeli, a seismically active city in the Marmara region, and this building class, which is preferred intensively, were considered. Quality and period parameters were defined based on structural and geometric properties. Depending on these parameters, nine main sub-classes were defined to represent the building stock in the region. First, considering the mean fragility curves and four different central damage ratio models, vulnerability curves for each sub-class were computed as a function of spectral acceleration. Then, probabilistic seismic hazard analyses were performed for stiff and soft soil conditions for different earthquake probabilities of exceedance in 50 years. In the last step, 90 loss curves were derived based on vulnerability and hazard results. Within the scope of the study, the comparative parametric evaluations for three different earthquake intensity levels showed that the structural damage ratio values for nine sub-classes changed significantly. In addition, the quality parameter was found to be more effective on a structure's damage state than the period parameter. It is evident that since loss curves allow direct loss ratio calculation for any hazard level without needing seismic hazard and damage analysis, they are considered essential tools in rapid earthquake risk estimation and mitigation initiatives.

Dynamics of Slender Rigid Blocks Mounted on the Seismic Isolation System (격리받침 위에 놓인 Slender 강체 블록의 동적거동)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.448-454
    • /
    • 2000
  • Piled multi-block system has been frequently adopted in the historic structures or monuments of cultural heritage. It is well known that such a structural system is very vulnerable to the earthquake shaking. If the structure is of slender type, then it may experience overturning at very low level intensity of ground shaking. One of the methods used to protect such structures from earthquake is seismic isolation system. But the behavior of multi-block systems mounted on the isolated basis is not well understood yet. In this paper we investigate the dynamic behavior of single slender rigid block mounted on the three different isolation systems, i.e., P-F system, FPS and LRB system. Sliding at the isolation interface of P-F system and FPS is formulated based on Coulomb friction. The mounted single block is assumed undergoing rocking or sticking only. Impacting of a single block is described using distinct element method (DEM). Free vibrations due to a prescribed initial conditions are studied. Responses to the harmonic excitation and earthquake motions are calculated

  • PDF

Seismic retrofitting of Fragavilla Monastery

  • Karantoni, Fillitsa V.
    • Earthquakes and Structures
    • /
    • v.5 no.2
    • /
    • pp.207-223
    • /
    • 2013
  • Practical seismic assessment and design of retrofit for the multitude of small ecclesiastical monuments that abound in the Balkans is the subject of this work. Application of the proposed procedures and methodologies are illustrated in an example case study, a small byzantine church located in Western Greece, which is the region with the highest seismicity in Europe. The church, known as the Fragavilla Monastery, had remained almost undamaged for 800 years, until 1993 when the Pyrgos earthquake caused critical damage mainly in the vaults. Linear elastic analysis to the recorded ground motion, capped by a biaxial failure criterion reproduced the developed damage. The same modelling and analysis procedure was subsequently used for assessment of the intended retrofitting measures. Proposed retrofitting measures included mitigation of the undesirable implications of past interventions along with a combination of strengthening schemes with externally bonded AFRPs strategically placed in the structure. The effectiveness of the proposed solutions is gauged by successful reduction of stress intensity in the critical regions and mitigation of stress localization throughout the structure.

Damping and frequency changes induced by increasing levels of inelastic seismic demand

  • Aguirre, Diego A.;Montejo, Luis A.
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.445-468
    • /
    • 2014
  • The objective in this research is to determine the feasibility of using changes on the dynamic properties of a reinforced concrete (RC) structure to identify different levels of seismic induced damage. Damping ratio and natural frequency changes in a RC bridge column are analyzed using different signal processing techniques like Hilbert Transforms, Random Decrement and Wavelet Transforms. The data used in the analysis was recorded during a full-scale RC bridge column shake table test. The structure was subjected to ten earthquake excitations that induced different levels of inelastic demand on the column. In addition, low-intensity white noises were applied to the column in-between earthquakes. The results obtained show that the use of the damping ratio and natural frequency of vibration as damage indicators is arguable.

Quasi-static cyclic displacement pattern for seismic evaluation of reinforced concrete columns

  • Yuksel, E.;Surmeli, M.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.3
    • /
    • pp.267-283
    • /
    • 2011
  • Although earthquakes generate random cyclic lateral loading on structures, a quasi-static cyclic loading pattern with gradually increasing amplitude has been commonly used in the laboratory tests because of its relatively low cost and simplicity compared with pseudo-dynamic and shake table tests. The number, amplitudes and sequence of cycles must be chosen appropriately as important parameters of a quasi-static cyclic loading pattern in order to account for cumulative damage matter. This paper aims to reach a new cyclic displacement pattern to be used in quasi-static tests of well-confined, flexure-dominated reinforced concrete (RC) columns. The main parameters of the study are sectional dimensions, percentage of longitudinal reinforcement, axial force intensity and earthquake types, namely, far-fault and near-fault.

Seismic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탐 실물 크기 모델의 지진시험)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.388-395
    • /
    • 1999
  • There occurred a moderate size earthquake of M=5 at Whagae-Myun Hadong-Gun Kyongsangnam-Do of Korea, It caused severe damage to the buildings and other structures is Sang-Gye-Sa a famous and beautiful Buddhist Temple, The 5-story stone pagoda was standing in front of Keumdang. The top component tipped over and fell to the ground during the earthquake. In order to have accurate and quantitative estimate of the intensity of earthquake a full-scale replica is made through rigorous verification process, The completed model was mounted on the shaking table and subjected to th seismic tests. It was observed that the top component overturned at 0.16 G of EPGA when the NS component of the 1940 el Centro earthquake records was used as the input motion. A brief history of this project is presented and important test results are report6ed and their implication is discussed.

  • PDF

Evaluation of Seismic Capacity and Estimation of Earthquake Damage for Existing Unreinforced Masonry Building in Korea (국내 조적조 건물의 내진성능평가 및 지진피해율 상정)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.535-542
    • /
    • 2006
  • In Seoul, more than 80 percent of residential buildings are constructed with unreinforced masonry(URM) buildings in early 1970 to 1990. In general, URM buildings have the advantages of reducing the construction time and easy to construction. However, URM buildings do not have enough strength against the lateral force. Moreover, low rise buildings have not adopted seismic designs, and for that reason a critical damage is expected with an earthquake. And also, the necessity of the seismic performance evaluation of existing building structures is raised through the Taiwan earthquake in 1999. The purpose of this study is to provide basic information for unreinforced masonry building in Korea by application of the proposed seismic evaluation method. In this study, seismic capacities of 50 existing unreinforced masonry buildings are evaluated based on the proposed method. Also, relationships of seismic capacities between Korean earthquake damage ratios of korean unreinforced masonry buildings are estimated. Results of this study were as follows; 1)Seismic retrofit was needed $8{\sim}48%$ in Korean unreinforced masonry buildings. 2)Korean unreinforced masonry buildings were expected to have severe damage under the earthquake intensity level experienced in Japan.

Structure and Sequence Stratigraphy in the Southwestern Area of the South China Sea (남중국해 남서부 지역에서의 지구조 분석 및 순차층서학적 연구)

  • Lee, Eung Gyu;Lee, Gi Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.179-190
    • /
    • 1999
  • The overall structural framework was studied using the regional 2D seismic data, followed by the sequence stratigraphic study on the 3D seismic and well- log data in the margin of the South Con Son basin of the South China Sea. This research contributes to delineate depositional stratigraphy, depositional environment and geologic history in the 3D seismic area of highly complicated faulting. Eight Miocene sequences were indicated on the 3D seismic and well-log data, in which the structural maps of each sequence boundary and the isochron maps for the corresponding sequence were made. The seismic facies were analyzed for each sequence volume and sequence boundary surface. The 3D seismic area is characterized by coal beds deposited in the transgression environment (transgression systems tract) and channel distributions just above the sequence boundaries. During the Early Miocene, the coals and thick shales deposited in the mangrove swamp representing the lower coastal plain environment. During the Mid to Late Miocene, thick clastic sediments deposited in the coastal to shallow shelf by regional subsidence and marine transgression. The isochron maps and structural patterns indicate that the sediments were transported from west to east or from northwest to southeast.

  • PDF

An Analysis of the Fault Plane Solution and Intensity on the Iksan Earthquake of 22 December 2015 (2015년 12월 22일 발생한 익산지진의 단층면해와 진도 분석)

  • Kim, Jin-Mi;Kyung, Jai Bok;Kim, Kwang-Hee
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.561-569
    • /
    • 2017
  • Fault plane solutions of the Iksan earthquake ($M_L=3.85$) and two aftershocks were obtained using the FOCMEC (FOCal MEChanism determination) program. The main event showed the characteristic of strike slip faulting with reverse component. It has the fault planes with NE-SW or NW-SE direction. This is similar to the fault characteristics of earthquake pattern in the inland area of the Korean Peninsula. In order to detect micro-earthquake events, continuous seismic waveform data of the thirteen seismic stations within a radius of 100km from epicenter were analyzed by PQLII program (PASSCAL, 2017) for the period from December 15, 2015 to January 22, 2016. The epicenters of nineteen micro-events were newly determined by Hypoinverse-2000 program. They are not concentrated along some lineaments or fault lines. The intensity of the Iksan earthquake was obtained by estimating the telephone inquiries, the degree of ground shaking or damage all around the southern peninsula. The instrumental intensity was also obtained using PGA (Peak Ground Acceleration) records. As a result, the maximum MM intensity was estimated to be V near the epicenter.