DOI QR코드

DOI QR Code

Seismic retrofitting of Fragavilla Monastery

  • Karantoni, Fillitsa V. (Department of Civil Engineering, University of Patras)
  • Received : 2012.10.28
  • Accepted : 2013.05.14
  • Published : 2013.08.07

Abstract

Practical seismic assessment and design of retrofit for the multitude of small ecclesiastical monuments that abound in the Balkans is the subject of this work. Application of the proposed procedures and methodologies are illustrated in an example case study, a small byzantine church located in Western Greece, which is the region with the highest seismicity in Europe. The church, known as the Fragavilla Monastery, had remained almost undamaged for 800 years, until 1993 when the Pyrgos earthquake caused critical damage mainly in the vaults. Linear elastic analysis to the recorded ground motion, capped by a biaxial failure criterion reproduced the developed damage. The same modelling and analysis procedure was subsequently used for assessment of the intended retrofitting measures. Proposed retrofitting measures included mitigation of the undesirable implications of past interventions along with a combination of strengthening schemes with externally bonded AFRPs strategically placed in the structure. The effectiveness of the proposed solutions is gauged by successful reduction of stress intensity in the critical regions and mitigation of stress localization throughout the structure.

Keywords

References

  1. Andreaus, U. (1996), "Failure criteria for masonry panels under in-plane loading", J. Struct. Eng. - ASCE, 122(1), 37-46. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:1(37)
  2. ANSYS (Version 10), Online help and reference manual of ANSYS.
  3. Bakhteri, J., Makhtar, A.M. and Sambasivam, S. (2004), "Finite element modelling of structural clay brick masonry subjected to axial compression", J. Teknologi, 41(B), 57-68.
  4. Bruneau, M. (1994), "State-of-the-art report on seismic performance of unreinforced masonry buildings", J. Struct. Eng. - ASCE, 120(1), 231-251.
  5. Gidigasu, M.D. (1974), "Degree of weathering in the identification of laterite materials for engineering purposes - a review", Eng. Geol., 8, 213-266. https://doi.org/10.1016/0013-7952(74)90001-5
  6. Gumaste, K.S., Rao, N.K.S., Reddy, V.B.V. and Jagadish, K.S. (2007), "Strength and elasticity of brick masonry prisms and wallettes under compression", Mater. Struct., 40, 241-253. https://doi.org/10.1617/s11527-006-9141-9
  7. IS 1893 (2002), Indian standard criteria for earthquake resistant design of structures, Bureau of Indian Standards, New Delhi, India.
  8. IS 3620-1979 (Reaffirmed 1998), Indian standard specification for laterite stone block for masonry, Bureau of Indian Standards, New Delhi, India.
  9. IS 4326-1993, Earthquake resistant design and construction of buildings - code of practice, 2nd revision, Bureau of Indian Standards, New Delhi, India.
  10. Jagadish, K.S., Raghunath, S. and Rao, N.K.S. (2003), "Behaviour of masonry structures during the Bhuj earthquake of January 2001", Proc. Indian Acad. Sci. (Earth Planet. Sci.), 112(3), 431-440.
  11. Jhung, M.J, (2009), "Seismic analysis of mechanical components by ANSYS", Korea Institute of Nuclear Safety, KINS/RR-685.
  12. Karantoni, F.V. and Fardis, M.N. (1992), "Computed versus observed seismic response and damage of masonry buildings", J. Struct. Eng. - ASCE, 118(7), 1804-1821. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:7(1804)
  13. Kasthurba, A.K. (2005), "Characterisation and Study of Weathering Mechanisms of Malabar Laterite for Building Purposes", Unpublished Ph.D. thesis, Dept. of Civil Engineering, IIT, Madras, India.
  14. Raghunath, S., Rao, K.S.N. and Jagadish, K.S. (2000), "Studies on The Ductility of Brick Masonry Walls with Containment Reinforcement", Proc. 6th Int. Seminar on Structural Masonry for Developing Countries, Bangalore, India.
  15. Raghunath, S. (2003), "Static and dynamic behaviour of brick masonry with containment reinforcement", Unpublished PhD thesis, Department of Civil Engineering, Indian Institute of Science, India.
  16. Sahin, A. (2010), "An seismic - a simple assistant computer program for implementing earthquake analysis of structures with ANSYS and SAP2000", The Nineth International Congress on Advances in Civil Engineering (ACE 2010), Trabzon, Turkey.
  17. Saikia, B., Vinod, K.S., Raghunath, S. and Jagadish, K.S. (2006), "Effect of reinforced concrete bands on dynamic behavior of masonry buildings", Indian Concrete J., 9-16, October.
  18. Sutapa, Das (2008), "Decay diagnosis of goan laterite stone monuments, 11 DBMC", 11th International Conference on Durability of Building Materials and Components, Istanbul, Turkey.
  19. Tavarez, F.A. (2001), "Simulation of behavior of composite grid reinforced concrete beams using explicit finite element methods", Master's Thesis, University of Wisconsin, Madison, Wisconsin.
  20. Thakkar, K.S. and Agarwal, P. (2000), "Seismic Evaluation of Earthquake Resistant and Retrofitting Measures of Stone Masonry Houses", 12WCEE 12th World Conference on Earthquake Engineering, Auckland, 0110 New Zealand.
  21. Unnikrishnan, S., Narasimhan, M.C. and Venkataramana, K. (2011), "Studies on uniaxial compressive strength of laterite masonry prisms", Int. J. Earth Sci. Eng. 4(2), 336-350.
  22. Vyas, Ch.U.V. and Reddy, V.B.V. (2010), "Prediction of solid block masonry prism compressive strength using FE model", Mater. Struct., 43(5),719-735. https://doi.org/10.1617/s11527-009-9524-9

Cited by

  1. Experimental study on RC frame structures strengthened by externally-anchored PC wall panels vol.22, pp.4, 2018, https://doi.org/10.12989/cac.2018.22.4.383
  2. Seismic performance of South Nias traditional timber houses: A priority ranking based condition assessment vol.18, pp.6, 2013, https://doi.org/10.12989/eas.2020.18.6.731
  3. Non-linear Pushover Analysis and simulation of progressive collapse mechanisms using FE Models for Nativity Church vol.21, pp.2, 2021, https://doi.org/10.12989/eas.2021.21.2.185