• Title/Summary/Keyword: Seismic characteristics evaluation

Search Result 252, Processing Time 0.023 seconds

Seismic Response Analysis of Nuclear Power Plant Structures and Equipment due to the Pohang Earthquake (포항지진에 대한 원자력발전소 구조물 및 기기의 지진응답분석)

  • Eem, Seung-Hyun;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.113-119
    • /
    • 2018
  • The probabilistic seismic safety assessment is one of the methodology to evaluate the seismic safety of the nuclear power plants. The site characteristics of the nuclear power plant should be reflected when evaluating the seismic safety of the nuclear power plant. The Korea seismic characteristics are strong in high frequency region and may be different from NRC Regulatory Guide 1.60, which is the design spectrum of nuclear power plants. In this study, seismic response of a nuclear power plant structure by Pohang earthquake (2017.11.15. (KST)) is investigated. The Pohang earthquake measured at the Cheongsong seismic observation station (CHS) is scaled to the peak ground acceleration (PGA) of 0.2 g and the seismic acceleration time history curve corresponding to the design spectrum is created. A nuclear power plant of the containment building and the auxiliary buildings are modeled using OPENSEES to analyze the seismic response of the Pohang earthquake. The seismic behavior of the nuclear power plant due to the Pohang earthquake is investigated. And the seismic performances of the equipment of a nuclear power plant are evaluated by the HCLPF. As a result, the seismic safety evaluation of nuclear power plants should be evaluated based on site-specific characteristics of nuclear power plants.

Seismic performance evaluation of school buildings in Turkey

  • Inel, Mehmet;Ozmen, Hayri Baytan;Bilgin, Huseyin
    • Structural Engineering and Mechanics
    • /
    • v.30 no.5
    • /
    • pp.535-558
    • /
    • 2008
  • This study evaluates seismic performance of the school buildings with the selected template designs in Turkey considering nonlinear behavior of reinforced concrete components. Six school buildings with template designs were selected to represent major percentage of school buildings in medium-size cities located in high seismic region of Turkey. Selection of template designed buildings and material properties were based on field investigation on government owned school buildings in several cities in western part of Turkey. Capacity curves of investigated buildings were determined by pushover analyses conducted in two principal directions. The inelastic dynamic characteristics were represented by equivalent single-degree-of-freedom (SDOF) systems and their seismic displacement demands were calculated under selected ground motions. Seismic performance evaluation was carried out in accordance with recently published Turkish Earthquake Code that has similarities with FEMA-356 guidelines. Reasons of building damages in past earthquakes are examined using the results of performance assessment of investigated buildings. The effects of material quality on seismic performance of school buildings were investigated. The detailed examination of capacity curves and performance evaluation identified deficiencies and possible solutions for template designs.

Seismic Performance Evaluation of Building Structures Based on the Adaptive Lateral Load Distribution (적응적 횡하중 분배방법을 이용한 건축구조물의 내진성능평가)

  • 이동근;최원호;정명채
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.39-58
    • /
    • 2004
  • It is very important that predict the inelastic seismic behavior exactly for seismic performance evaluation of a building in the performance based seismic design. Evaluation method of seismic performance based on the pushover analysis reflected in PBSE was developed by some researchers. For the evaluation of inelastic global and local seismic responses by pushover analysis exactly. lateral load distribution should be adjusted and reflected the dynamic characteristics of structural system and various seismic ground motions. And performance point should be determined based on the evaluation of reasonable deformation capacity of a building more exactly. An effective method based on the improved the adaptive lateral load distribution and the equivalent responses of a multistory building is proposed in this study to efficiently estimate the accurate inelastic seismic responses. The proposed method can be used to evaluate the seismic performance for the global inelastic behavior of a building and to accurately estimate its local inelastic seismic responses. In order to demonstrate the accuracy and validity of this method, inelastic seismic responses estimated by the proposed method are compared with those obtained from other analytical methods.

Seismic Reliability Evaluation of Electric Power Transmission Systems in Low and Moderate Seismicity Regions (중약진 지역에서의 전력송전시스템의 지진재해 신뢰성 평가)

  • 고현무;김영호;박원석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.155-162
    • /
    • 2002
  • A technique for the seismic reliability evaluation of electric power transmission systems(EPTS) adapted to ground motion characteristics of Korea has been developed to evaluate reliability indices corresponding to the whole system and to each node within. A network model with nodes and links for EPTS has been established, and a seismic substation-fragility curve obtained from seismic fragilities of power system facilities has been derived. A point source model, the doubly truncated Gutenberg-Richter relationship, and earthquake intensity attenuation formula have been applied to simulate seismic events. Using Monte-Carlo simulation method, the seismic reliability of EPTS is evaluated and, it appeared that seismic effect on EPTS in low and moderate seismicity regions has to be considered.

  • PDF

The Analysis for Dynamic Behavior Characteristics of Concrete Gravity Dams (콘크리트 중력식 댐의 동적 거동 특성 분석)

  • Koo Min-Se;Park Kuk-Dong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.393-399
    • /
    • 2005
  • The purpose of this study is to suggest some references of maintenance and design of concrete gravity dams by analyzing dynamic characteristics in x, y, z directions. It is considered as additional mass, soil interaction for numerical dynamic analysis for gravity concrete dams in Han River basin as some cases. The result shows that the overflow structure can be possibly underestimated for the evaluation of the seismic performance using seismic intensity, modified seismic intensity methods. A much more research is still necessary for the evaluation of comprehensive seismic performance of concrete gravity dam

  • PDF

Nonlinear Behavior Characteristics and Seismic Performance of the Existing RC Piers without Seismic Detailing (비내진 상세 기존 RC 교각의 비선형 거동특성 및 내진성능)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.327-334
    • /
    • 2000
  • The seismic performance evaluation of the existing non-seismic detailed RC piers has risen as urgent task for rational and cost-effective seismic retrofitting works as well as development of new seismic design concept. The scale model test has been conducted to investigate nonlinear behavior characteristics and the seismic performance of existing piers with lap-spliced longitudinal reinforcements in the plastic hinge zone which are of the solid circular and the hollow rectangular section. The lap splice in this zone is found to cause premature bond failure. The experimental results show very poor seismic performance of circular section pier but relatively large ductility of the rectangular one.

  • PDF

Analysis on the Seismic Performance of Ceiling System in School Buildings (국내 학교시설 천장재의 내진성능 분석)

  • Park, Sung-Chul;Cho, Jin-Il;Jung, Tae-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • The purpose of this study is to develop the evaluation model of school facilities in terms of seismic performance during safety education in the school field. This study is composed of four stages with a view to developing user oriented evaluation models that can be utilized during earthquake safety education on ceiling system. and First stage analyze the evaluation guidelines to find evaluation methods and items. Based on the items, site survey was conducted to derive the characteristics of seismic performance of domestic school buildings in terms of ceiling system. Third stage analyzes the seismic performance of ceiling system. Final stage is to derive recommendations based on the results.

Failure Pattern of Space Frame Pier Structures and Simple Check Method for Seismic Performance (입체 라멘 교각 구조물의 파괴 패턴 및 간이 내진성능 평가법)

    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.97-106
    • /
    • 1999
  • In order to check the necessity of seismic reinforcement for a great number of existing structures effectively, it might be desirable to introduce the multi-step seismic evaluation system. This paper presents close relationships between shear-to-moment capacity ratio of a member and seismic performance of structures concerned through the failure mechanism investigation in the view of geological and structural characteristics. Based on it, the simple seismic performance evaluation method has been proposed and its effectiveness was verified by comparing with the damage condition of structures damaged under Hyogo-Ken Nambu Earthquake.

  • PDF

Comparison of Seismic Responses of Underground Utility Tunnels Using Simplified Analysis Methods (단순화 해석 방법에 따른 지하공동구 지진 응답 산정 비교)

  • Kim, Dae-Hwan;Lim, Youngwoo;Seo, Hyun-Jeong;Lee, Hyerin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.205-213
    • /
    • 2024
  • In the seismic evaluation of underground utility tunnels, selecting an analytical method is critical to estimating reasonable seismic responses. In simplified pseudo-static analysis methods widely applied to typical seismic design and evaluation of underground tunnels in practice, it is essential to check whether the methods provide valid results for cut-and-cover tunnels buried in shallow to medium depth. The differences between the two simplified pseudo-static methods are discussed in this study, and the analysis results are compared to those obtained from FLAC models. In addition to the analysis methods, seismic site classification, overburden soil depth, and sectional configuration are considered variables to examine their effects on the seismic response of underground utility tunnels. Based on the analysis results, the characteristics derived from the concepts and details of each simplified model are discussed. Also, general observations are made for the application of simplified analysis methods.

Evaluation of Seismic Safety in School Buildings Applying Artificial Seismic Waves in Earthquake Magnitude of Korea (한국형 중진지역의 인공지진파 생성을 통한 학교건물 내진안전성 평가)

  • Kim, Seung-Hyun;Park, Young-Binuk;Kang, Jun-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • This report describes the development and stability evaluation of a seismic retrofit method to evaluate the seismic performance of existing school buildings by analyzing the earthquake waveforms that occurred in Korea. Currently, Facilities for seismic retrofit designed for excessive reinforcement are being applied. To compensate for this, optimised the retrofit mothod suitable for domestic situation considering the characteristics of the seismic region, generated a Korean-style artificial seismic wave that meets the seismic design criteria, which is less frequent than other countries.