• 제목/요약/키워드: Seismic building Code

검색결과 273건 처리시간 0.027초

The Structural Design of Tianjin Goldin Finance 117 Tower

  • Liu, Peng;Ho, Goman;Lee, Alexis;Yin, Chao;Lee, Kevin;Liu, Guang-lei;Huang, Xiao-yun
    • 국제초고층학회논문집
    • /
    • 제1권4호
    • /
    • pp.271-281
    • /
    • 2012
  • Tianjin Goldin Finance 117 tower has an architectural height of 597 m, total of 117 stories, and the coronation of having the highest structural roof of all the buildings under construction in China. Structural height-width ratio is approximately 9.5, exceeding the existing regulation code significantly. In order to satisfy earthquake and wind-resisting requirements, a structure consisting of a perimeter frame composed of mega composite columns, mega braces and transfer trusses and reinforced concrete core containing composite steel plate wall is adopted. Complemented by some of the new requirements from the latest Chinese building seismic design codes, design of the super high-rise building in high-intensity seismic area exhibits a number of new features and solutions to professional requirements in response spectrum selection, overall stiffness control, material and component type selection, seismic performance based design, mega-column design, anti-collapse and stability analysis as well as elastic-plastic time-history analysis. Furthermore, under the prerequisite of economic viability and a series of technical requirements prescribed by the expert review panel for high-rise buildings exceeding code limits, the design manages to overcome various structural challenges and realizes the intentions of the architect and the client.

지진하중이 터빈-발전기 기초의 설계에 미치는 영향 (Impact Analysis of Seismic Load on the Design of Turbine-Generator Foundations)

  • 김재석;조양회;안대호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.224-231
    • /
    • 2003
  • The purpose of this study is to review and validate the seismic analysis procedures of turbine-generator foundation specified in the Korea Building Code which adopts equivalent static analysis. Typical machines and foundations were chosen and various kinds of parametric studies were peformed and the results were compared with the detail dynamic analysis. The general trend of the study results showed that the most of the computed responses of equivalent static analysis are smaller than those of the dynamic analyses(response spectrum analysis and time history analysis), which implies the existing seismic analysis technique using the existing Building Code may give unconservative design results. The results also showed that the seismic loads are one of the governing design parameters of the turbine-generator foundations.

  • PDF

Seismic energy dissipation in torsionally responding building systems

  • Correnza, J.C.;Hutchinson, G.L.;Chandler, A.M.
    • Structural Engineering and Mechanics
    • /
    • 제3권3호
    • /
    • pp.255-272
    • /
    • 1995
  • The paper considers aspects of the energy dissipation response of selected realistic forms of torsionally balanced and torsionally unbalanced building systems, responding to an ensemble of strong-motion earthquake records. Focus is placed on the proportion of the input seismic energy which is dissipated hysteretically, and the distribution of this energy amongst the various lateral load-resisting structural elements. Systems considered comprise those in which torsional effects are discounted in the design, and systems designed for torsion by typical code-defined procedures as incorporated in the New Zealand seismic standard. It is concluded that torsional response has a fundamentally significant influence on the energy dissipation demand of the critical edge elements, and that therefore the allocation of appropriate levels of yielding strength to these elements is a paramount design consideration. Finally, it is suggested that energy-based response parameters be developed in order to assist evaluations of the effectiveness of code torsional provisions in controlling damage to key structural elements in severe earthquakes.

Evaluation of seismic performance factors for steel DIAGRID structural system design

  • Lee, Dongkyu;Shin, Soomi;Ju, Youngkyu
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.735-755
    • /
    • 2016
  • This article presents a proposed analytical methodology to determine seismic force-resisting system R-values for steel diagrid framed systems. As current model building codes do not explicitly address the seismic design performance factors for this new and emerging structural system, the purpose of this study is to provide a sound and reliable basis for defining such seismic design parameters. An approach and methodology for the reliable determination of seismic performance factors for use in the design of steel diagrid framed structural systems is proposed. The recommended methodology is based on current state-of-the-art and state-of-the practice methods including structural nonlinear dynamic analysis techniques, testing data requirements, building code design procedures and earthquake ground motion characterization. In determining appropriate seismic performance factors (R, ${\Omega}_O$, $C_d$) for new archetypical building structural systems, the methodology defines acceptably low values of probability against collapse under maximum considered earthquake ground shaking.

고차모드 효과를 고려한 층 지진하중 분배 (the height-wise distribution of lateral seismic forces considering the contribution of the higher modes)

  • 황준호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.273-280
    • /
    • 1999
  • The base shear and the veritcal distribution of shears along the height of a building are two fundamental measures that define the design seismic load. But the method specified in Korean building code does not give an appropriate distribution for buildings of tall or longer period because it roughly account for the contributions of the higher modes. several methods to give a better distribution of seismic forces have been proposed. But they have not been introduced into the seismic codes yet probably because they cannot solve all the above-mentioned problems. This paper deals with the distribution of lateral seismic forces along the height of a building to account for the contribution of the higher modes. After reviewing some existing distributions in seismic codes and literatures moment-resisting frames with various stories were studied by modal analysis for a wide range of fundamental period and the stiffness ratio of the buiding. As a result of the analysis a new expression for the distribution of seismic forces is proposed and compared with those of some codes and dynamic analysis.

  • PDF

Vulnerability assessment of strategic buildings based on ambient vibrations measurements

  • Mori, Federico;Spina, Daniele
    • Structural Monitoring and Maintenance
    • /
    • 제2권2호
    • /
    • pp.115-132
    • /
    • 2015
  • This paper presents a new method for seismic vulnerability assessment of buildings with reference to their operational limit state. The importance of this kind of evaluation arises from the civil protection necessity that some buildings, considered strategic for seismic emergency management, should retain their functionality also after a destructive earthquake. The method is based on the identification of experimental modal parameters from ambient vibrations measurements. The knowledge of the experimental modes allows to perform a linear spectral analysis computing the maximum structural drifts of the building caused by an assigned earthquake. Operational condition is then evaluated by comparing the maximum building drifts with the reference value assigned by the Italian Technical Code for the operational limit state. The uncertainty about the actual building seismic frequencies, typically significantly lower than the ambient ones, is explicitly taken into account through a probabilistic approach that allows to define for the building the Operational Index together with the Operational Probability Curve. The method is validated with experimental seismic data from a permanently monitored public building: by comparing the probabilistic prediction and the building experimental drifts, resulting from three weak earthquakes, the reliability of the method is confirmed. Finally an application of the method to a strategic building in Italy is presented: all the procedure, from ambient vibrations measurement, to seismic input definition, up to the computation of the Operational Probability Curve is illustrated.

Seismic force evaluation of RC shear wall buildings as per international codes

  • Jayalekshmi, B.R.;Chinmayi, H.K.
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.191-209
    • /
    • 2016
  • Seismic codes are the best available guidance on how structures should be designed and constructed to ensure adequate resistance to seismic forces during earthquakes. Seismic provisions of Indian standard code, International building code and European code are applied for buildings with ordinary moment resisting frames and reinforced shear walls at various locations considering the effect of site soil conditions. The study investigates the differences in spectral acceleration coefficient ($S_a/g$), base shear and storey shear obtained following the seismic provisions in different codes in the analysis of these buildings. Study shows that the provision of shear walls at core in low rise buildings and at all the four corners in high rise buildings gives the least value of base shear.

동일한 지진구역에 위치한 건축 구조물의 내진거동을 기초로한 기존 내진설계 평가 (Evaluation of the Current Seismic Design Procedures Based on the Seismic Performance of the Building Located in the Same Seismic Area)

  • 한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.160-166
    • /
    • 1997
  • Current Seismic Design Procedure has been developed and improved mostly based on the experiences of the past earthquakes. Many engineers and researchers believe that the seismic codes and provisions are adequate for the basic objective of the code which is "life-safe". However they doubt the performance of the structure during the earthquake. The seismic code seems the black box for the designers which means it is not transparent since the designer can not predict the level of the damage of the structure under future earthquakes. This purpose of this study is to check the validity of the current seismic design procedures. Two structures with different heights are designed and their seismic performances are evaluated for this purpose. Both structures are assumed to be located at the same strong seismic zone.

  • PDF

Investigating the effect of bond slip on the seismic response of RC structures

  • Fallah, Mohammad Mehdi;Shooshtari, Ahmad;Ronagh, Hamid Reza
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.695-711
    • /
    • 2013
  • It is reasonable to assume that reinforced concrete (RC) structures enter the nonlinear range of response during a severe ground motion. Numerical analysis to predict the behaviour therefore must allow for the presence of nonlinear deformations if an accurate estimate of seismic response is aimed. Among the factors contributing to inelastic deformations, the influence of the degradation of the bond slip phenomenon is important. Any rebar slip generates an additional rotation at the end regions of structural members which are not accounted for in a conventional analysis. Although these deformations could affect the seismic response of RC structures considerably, they are often neglected due to the unavailability of suitable models. In this paper, the seismic response of two types of RC structures, designed according to the Iranian concrete code (ABA) and the Iranian seismic code (2800), are evaluated using nonlinear dynamic and static analyses. The investigation is performed using nonlinear dynamic and static pushover analysis considering the deformations due to anchorage slip. The nonlinear analysis results confirm that bond slip significantly influences the seismic behavior of RC structure leading to an increase of lateral deformations by up to 30% depending on the height of building. The outcomes also identify important parameters affecting the extent of this influence.

Effect of poorly-compacted backfill around embedded foundations on building seismic response

  • Kim, Yong-Seok
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.549-561
    • /
    • 2012
  • Many building foundations are embedded, however it is not easy to compact the backfill around the foundation especially for the deeply embedded ones. The soil condition around the embedded foundation may affect the seismic response of a building due to the weak contact between the soil and the foundation. In this paper, the response accelerations in the short-period range and at the period of 1 second (in the long-period range) for a seismic design spectrum specified in the IBC design code were compared considering perfect and poor backfills to investigate the effect of backfill compaction around the embedded foundation. An in-house finite-element software (P3DASS) which has the capability of horizontal pseudo-3D seismic analysis with linear soil layers was used to perform the seismic analyses of the structure-soil system with an embedded foundation. Seismic analyses were carried out with 7 bedrock earthquake records provided by the Pacific Earthquake Engineering Research Center (PEER), scaling the peak ground accelerations to 0.1 g. The results indicate that the poor backfill is not detrimental to the seismic response of a building, if the foundation is not embedded deeply in the soft soil. However, it is necessary to perform the seismic analysis for the structure-soil system embedded deeply in the soft soil to check the seismic resonance due to the soft soil layer beneath the foundation, and to compact the backfill as well as possible.