• 제목/요약/키워드: Seismic Safety

검색결과 1,007건 처리시간 0.026초

원자력발전소 비안전등급 배관의 내진해석 방법론 연구 (Seismic Analysis Methodology for Non-Nuclear Safety Piping in Nuclear Power Plants)

  • 서건창;반치범
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Currently, there is no technical standard and regulation for seismic analysis of non-nuclear safety piping. Accordingly, ASME Sec.III ND, a standards applied to safety class 3 piping, is applied. However, the technical standard applied for other than seismic analysis is ASME B31, which leads to controversy. In this study, the feasibility of applying ASME B31E was confirmed by reviewing rulescomparing technical standards, and evaluating piping allowable stress margins. The evaluation revealed that applying ASME B31.1 as a technical standard is too conservative compared to ASME Sec.III ND. On the other hand, ASME B31E (issued at the request of the industry) clearly presents the technical standards for seismic analysis of ASME B31 piping, and shows a similar level of conservatism compared to ASME Sec.III ND. It is expected to reduce the controversy over technical standards for seismic analysis of non-nuclear safety piping by applying ASME B31E.

면진된 비상디젤발전기의 지진위험도 평가 (Seismic Risk Evaluation of Isolated Emergency Diesel Generator System)

  • 김민규;대조정수;전영선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.217-222
    • /
    • 2007
  • An Emergency Diesel Generator (EDG) is one of the safety related equipments of a Nuclear Power Plant. The seismic capacity of an EDG in nuclear power plants influences the seismic safety of the plants significantly. A recent study showed that the increase of the seismic capacity of the EDG could reduce the core damage frequency (CDF) remarkably. It is known that the major failure mode of the EDG is a concrete coning failure due to a pulling out of the anchor bolts. The use of base isolators instead of anchor bolts can increase the seismic capacity of the EDG without any major problems. This study introduces a seismic risk analysis method and presents sample results about the seismically isolated and conventional EDG system.

  • PDF

점성 감쇠기를 이용한 인접 비대칭 강성 구조물의 내진보강 최적설계 (Optimal Seismic Reinforcement Design of Adjacent Asymmetric-Stiffness Structures with Viscous Dampers)

  • 성은희
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.60-70
    • /
    • 2022
  • This paper proposes an optimal design method of a seismic reinforcement system for the seismic performance of adjacent asymmetric-stiffness structures with viscous dampers. The first method considers plan asymmetry for efficient seismic reinforcement, and evaluates the seismic performance of optimal design applied to two cases of modeling: adjacent stiffness-asymmetric structures and adjacent stiffness-symmetric structures. The second method considers the response of asymmetric structures to derive the optimal objective function, and evaluates seismic efficiency of the objective function applied to two cases of responses: horizontal displacement and torsion. Numerical analyses are conducted on 7- and 10-story structures with a uni-asymmetric-stiffness plan using six cases of historic earthquakes, normalized to 0.4g. The results indicate that the seismic performance is excellent as modeled by adjacent asymmetric-stiffness structures and how much horizontal displacement is applied as the objective function.

연약지반상 지진하중을 고려한 철도노반의 안정성 검토에 관한 연구 (A study on the Stability of Rail way Construction on the Reclaimed Land for Domestic Marine Clay Using the Seismic Analysic)

  • 김영수;김무일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1071-1076
    • /
    • 2004
  • The purpose. in this study. is to analyze liquefaction potential of Inchon International Airport at the Area Phase ' I ' for Railway Construction of all, seismic response was analyzed using the computer program, Shake91. Four methods proposed by Seed & Idriss. Eurocode, Iwasaki & Tatsuoka. and Ishihara were used for assessment of liquefaction potential and safety factors calculated form these methods are compared. Based on the results of seismic response analysis, the maximum acceleration at the ground surface is larger than that evaluated site factor effect by using site factor because these areas are composed of very loose sand clay. Especially, in the case of analysis with long period earthquake data. it is appeared that the acceleration of earthquake is amplified more largely. Therefore, accurate seismic response analysis is suggested for the design on the important structures on reclaimed land. The analytical results of liquefaction potential show that the increments of N-value and effective overburden pressure with remediation make safety factors increase. Through comparing the safety factors evaluated from four method, the safety factor calculated by See & Idriss method in the lowest one and it is found that the SPT N-value effect the safety factor very largely. And, Iwasaki & Tatsuoka method is affected by various factors such as average grain size. fine contents, confining pressure. In conclusion. to minimize earthquake Risk by liquefaction, the efficient remediation is essential and seismic response analysis should be carride out.

  • PDF

쌍둥이 인접구조물의 진동 제어를 위한 비대칭 지진격리 연결 제어시스템의 매개변수연구 (Parametric Study of Asymmetric Base-Isolation Coupling Control System for Vibration Control of Adjacent Twin Buildings)

  • 김다위;박원석;옥승용
    • 한국안전학회지
    • /
    • 제37권3호
    • /
    • pp.45-51
    • /
    • 2022
  • This paper focuses on a recently proposed asymmetric base-isolation coupling control system (ABiCS) for the vibration control of adjacent twin buildings. The ABiCS consists of inter-story diagonal dampers, a connecting damper between the two buildings, and a seismic isolation device at the base floor of one building. To investigate the control characteristics of ABiCS, a parametric study was performed by numerically simulating the 20-story twin buildings. In the parametric study, the control capacities of the inter-story diagonal dampers, connecting damper, and seismic isolation device were considered as varying parameters. The parametric study results indicate that the connecting damper between the two buildings reduces the responses of both buildings only at optimal or near-optimal capacity. In addition, adjusting the stiffness of the base isolation is found to be the most effective method for improving seismic performance and achieving cost-effectiveness. Accordingly, we presented a scenario-based performance improvement approach in which reducing the stiffness of the base isolation device could be an effective technique to improve the seismic performance of both buildings. However, note that checking the maximum allowable displacement of the base isolation device is essential.

국가산업단지의 지진재난 내진보강대책 수립 연구 (Study on Establishing Earthquake-resistance Reinforcement Measures for Earthquake Disasters in National Industrial Complexes)

  • 송창영
    • 한국재난정보학회 논문집
    • /
    • 제19권4호
    • /
    • pp.882-896
    • /
    • 2023
  • 연구목적: 국가산업단지 공장시설물이 보유한 내진설계의 잠재적 위험과 안전지도 및 점검의 미비점을 효과적으로 향상시킬 수 있는 안전관리 및 내진보강대책 마련을 목적으로 한다. 연구방법: 본 연구에서는 국가산업단지의 지진재난 대비 안전관리 현황 및 관리체계 등 지진재난 안전관리 전반에 관한 조사·분석을 통해 문제점 및 개선방안을 도출하였고, 국가산업단지 내 입주기업체 내진설계 실태조사를 실시하여 시설유형과 구조적 특성에 기반한 개선방안을 제시하였다. 연구결과: 결론적으로 국가산업단지 지진재난 대비 안전관리 및 내진보강에 대한 문제점을 정리하여 4가지 유형별(내진성능 평가 및 관련 제도 보완, 입주기업 및 지자체 권한, 내진보강 및 안전관리 지원대책, 조직의 역량강화)로 개선방안을 도출하였다. 결론: 이를 기반으로 국가산업단지 입주기업이 지진재난을 대비하여 추진해야 하는 내진보강 대책을 마련하였으며, 각 대책별 세부적인 방안을 제시하였다.

콘크리트 구조물에 대한 뉴질랜드 내진설계 규준의 특성 (Characteristics of Seismic Design of Concrete Structures in New Zealand Standards(NZS))

  • 이한선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.375-382
    • /
    • 2000
  • This paper briefly summarizes the basic concepts and main characteristics of seismic design of New Zealand Standards(NZS) with regard to reinforced concrete(RC) structures. NZS used the concept of the capacity design and the limit state design to satisfy the requirements of serviceability and safety. Plastic mechanisms and details with respect to the limit state of safety are briefly presented in this paper. The understanding of this advanced seismic design concept will enable us to implement the basic theory of capacity design and contribute to the development of Korean seismic code in new generation,

  • PDF

마찰진자시스템의 강성중심 변화에 따른 면진된 원전 구조물의 지진응답평가 (Seismic Response Evaluation of Seismically Isolated Nuclear Power Plant with Stiffness Center Change of Friction Pendulum Systems)

  • 석철근;송종걸
    • 한국지진공학회논문집
    • /
    • 제21권6호
    • /
    • pp.265-275
    • /
    • 2017
  • In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.

원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험 (Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components)

  • 장성진;전법규;박동욱;김성완
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

철근콘크리트 교량의 충격전달장치 앵커시스템의 전단파괴거동 (Shear Fracture Behavior of Anchor Systems for Shock Transmission Unit in RC Bridge)

  • 김태상;송하원;변근주;안창모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1097-1102
    • /
    • 2001
  • Seismic safety of continuous span concrete bridge can be enhanced by distributing a large seismic lateral load to each supporting pier. A new viscoelastic device called Shock Transmission Unit(STU), which is a simple cylinder-piston assembly packed with a so-called silicone putty compound, enables the lateral seismic load to be transmitted to the pier by installation of the device to movable bearings of the bridge. The seismic safety of concrete bridges having the STU depends on not only safety of the bridges globally but also safety of anchor systems which anchors the STU to concrete pier. An experimental investigation is performed to study the behavior of cast-in-place anchor and post-installed anchor subjected to shear load statically and cyclically according to different edge distance, embedment length, and anchor spacing. Finally, the experimental results are compared with results by design methods of ACI and CCD, and results by FEM analysis.

  • PDF