• 제목/요약/키워드: Seismic Capacity Evaluation

검색결과 410건 처리시간 0.037초

지진피해를 받은 철근콘크리트 건물의 잔존내진성능평가 (Evaluation of Post-earthquake Seismic Capacity of Reinforced Concrete Buildings suffering from earthquakes)

  • 강대언;이원호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.105-108
    • /
    • 2005
  • In damage investigation of building structures suffering from earthquake, estimation of residual seismic capacity is essential in order to access the safety of the building against aftershocks and to judge the necessity of repair and restoration. It has been proposed that an evaluation method for post-earthquake seismic capacity of reinforced concrete buildings based. on the residual energy dissipation capacity (the residual seismic capacity ratio )in lateral force-displacement curve of structural members. The proposed method was adopted in the Japanese 'Damage Level Classification Standard' revised in 200l. To evaluate the residual seismic capacity of RC column, experimental tests with positive and negative cyclic loading was carried out using RC building column specimen. Parameters used by the experiment are deformability and member proportion. From the test results, it is appropriated that the residual seismic capacity of RC buildings damaged by earthquakes is evaluated using the method in the Guideline.

  • PDF

기존 학교 건축물의 내진성능평가 및 보강방안 제안 (Proposed Seismic Performance Evaluation Enhancement for Existing School Building)

  • 황지훈;장정현;양경석;최재혁
    • 교육시설 논문지
    • /
    • 제19권4호
    • /
    • pp.29-38
    • /
    • 2012
  • Recently large scale earthquake s are occurred around the world following the damage of buildings. So the interest of preparing for earthquake seismic design and seismic performance has becoming high. School buildings are though used for educational purpose; they are also used as emergency shelter for local residents during earthquake disaster. However, the current seismic design ratio of our country (Korea) is 3.7% and if massive earthquake is occurred it follows a serious damage. In order to overcome this situation, seismic performance evaluation is carried out for existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear static analysis on existing school buildings for ATC-40 and FEMA-356 are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to verify the effect of retrofit enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effect of seismic retrofit time history analysis using nonlinear dynamic analysis is also performed and nonlinear behavior of earthquake load of seismic retrofit of structures was also investigated.

층간변위를 기반으로 한 다층구조물의 내전성능 평가를 위한 역량스펙트럼법의 개발 (Capacity Spectrum Method for Seismic Performance Evaluation of Multi-Story Building Based on the Story Drift)

  • 김선필;김두기;곽효경;고성혁;서형열
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • The existing capacity spectrum method (CSM) is based on the displacement based approach for seismic performance and evaluation. Currently, in the domestic and overseas standard concerning seismic design, the CSM to obtain capacity spectrum from capacity curve and demand spectrum from elastic response spectrum is presented. In the multistory building, collapse is affected more by drift than by displacement, but the existing CSM does not work for story drift. Therefore, this paper proposes an improved CSM to estimate story drift of structures through seismic performance and evaluation. It uses the ductility factor in the A-T domain to obtain constant-ductility response spectrum from earthquake response of inelastic system using the drift and capacity curve from capacity analysis of structure.

  • PDF

초고층 철골 건축물의 내진성능평가를 위한 Drift Capacity 산정 프로세스 (Determination Process of Drift Capacity for Seismic Performance Evaluation of Steel Tall Buildings)

  • 민지연;오명호;김명한;김상대
    • 한국강구조학회 논문집
    • /
    • 제18권4호
    • /
    • pp.481-490
    • /
    • 2006
  • 지진의 피해를 입은 후 건물의 실제 성능은 많은 요인에 영향을 받는다. 신축 구조물이나 기존 구조물의 지진 성능 예측은 복잡하다. 그 이유는 고려되어져야 하는 많은 요소와 지진 반응의 복잡성뿐만 아니라 이러한 예측과 관련된 타고난 불확실성 과 가변성 때문이다. 본 연구의 목적은 구조물의 능력 평가와 반응 요구에서의 불확실성과 가변성의 적절한 취급과 결합이다. 일관된 방법으로 demand와 capacity에서의 불확실성과 가변성을 설명하기 위하여 신뢰성 이론에 기초한 성능평가의 접근 방법이 초고층 철골 건축물의 내진성능평가 법으로 채택되어져 오고 있다. 신뢰성 이론에 근거한 내진성능평가에 대한 기본 체계와 통계적 연구에 대한 핵심 요소를 요약하였다. dema nd 요소와 capacity 요소의 통계적인 분석을 위하여 국내 기준에 맞는 전형적인 초고층 철골 건축물을 36개 설계하였다. global drift capacity 산정을 위해 철골 모멘트 골조 건물을 증분동해석 하였다.

수정된 능력스펙트럼을 이용한 건축구조물의 내진성능평가 (Seismic Performance Evaluation of Building Structures Using Modified Capacity Spectrum)

  • 최원호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.267-274
    • /
    • 2000
  • Current seismic design codes for building structures are based on the method which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. The capacity spectrum method using the nonlinear static(pushover) analysis is becoming a popular tool for evaluating the seismic performance of existing and new building structures. By means of a graphical procedure capacity spectrum method esimates the performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. In the method the relation between base shear estimated by a nonlinear static analysis and horizontal displacement is used. Capacity spectrum is usually expressed as what represent the responses of the equivalent single degree of freedom (ESDOF) system for the building structures. However there are some problems in converting procedures into ESDOF system which include not considering the effect of higher modes of structures. The objective of this paper is to compare and verify existing methods and suggest the modified capacity spectrum for seismic performance evaluation of building structures.

  • PDF

Post-earthquake capacity evaluation of R/C buildings based on pseudo-dynamic tests

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Structural Engineering and Mechanics
    • /
    • 제24권1호
    • /
    • pp.91-105
    • /
    • 2006
  • In this paper, post-earthquake capacity evaluation method of reinforced concrete buildings was studied. Substructure pseudo-dynamic test and static loading test of first story column in a four-story R/C building was carried out in order to investigate the validity of the evaluation method proposed in the Damage Assessment Guideline (JBDPA 2001). In pseudo-dynamic test, different levels of damage were induced in the specimens by pre-loading, and input levels of seismic motion, at which the specimens reached to the ultimate stage, were examined. From the experimental result, no significant difference in damage levels such as residual crack width between the specimens under static and pseudo-dynamic loading was found. It is shown that the seismic capacity reduction factors ${\eta}$ can provide a reasonable estimation of post-earthquake seismic capacity of R/C buildings suffered earthquakes.

수평이축방향 내진역량시험과 내진성능평가 절차 (Procedures of Biaxial Seismic Capacity Test and Seismic Performance Evaluation)

  • 김재관;김익현;이재호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.453-460
    • /
    • 2001
  • The seismic capacity of columns usually has been tested in uniaxial loading condition. The seismic performance used to be evaluated under the same assumption. Since the real earthquake motion is multi-directional, the effects of multi-directional excitation on the seismic capacity of structures need to be carefully examined. In this paper, a frequency dependent alternate biaxial cyclic loading test is proposed as an evaluation method of seismic capacity under multi-directional excitation. Four test specimens were made and tested to study the degradation of strength, stiffness and ductility under biaxial loading condition. A multi- directional excitation. The capacity is obtained using frequency dependent alternate biaxial cyclic loading test. The orthogonal effect is taken into account by increasing the demand.

  • PDF

수직적 비정형성을 지니는 구조물의 내진성능평가 (Seismic Capacity Evaluation of the Structures with Vertical Irregularities)

  • 홍성걸;김남희;하태휴
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.208-215
    • /
    • 2001
  • The vertical irregularities occurred in the structure may lessen the overall seismic capacity of the structure. Seismic capacity evaluation guidelines (e.g. FEMA 175, ATC-14) propose the criterion for the vertical irregularities of mass, stiffness and strength respectively. But, the criterion seems groundless and leads us to make a true/false decision only. This study is to draw a reasonable basis on which multi-level grading is possible based fur the evaluation of existing buildings. Time history analysis for 3-,5-, and 10-story steel frame structures has been performed using several earthquake data. ANN (Artificial Neural Network) is introduced to find the relative contribution factor of the irregularities along the irregular position. Also, the application system fur the seismic capacity evaluation can be established using the trained ANN.

  • PDF

역량스펙트럼법에 의한 교량 구조물의 내진성능평가 (Seismic Capacity Evaluation of Bridge Structure using Capacity Spectrum Method)

  • 박연수;오백만;박철웅;서병철
    • 한국지진공학회논문집
    • /
    • 제7권5호
    • /
    • pp.67-73
    • /
    • 2003
  • 현 도로교의 내진해석은 구조물이 하중 이상의 강도를 갖도록 하는 하중기반해석법에 근거하고 있다. 본 연구에서는 이러한 하중기반해석의 대안책으로 구조물의 성능평가 대상을 변위로 하는 변위기반해석의 일종인 역량스펙트럼법을 제시하였다. 하중기반해석에서 내진설계가 수행되어진 기존 철근콘크리트 교각에 대하여 역량스펙트럼법에 의한 내진성능을 평가하였다. 그 결과, 역량스펙트럼법은 간편하고 신속하게 구조물의 비탄성 응답을 현실적으로 평가할 수 있었으며 비탄성 응답을 일으키는 다양한 지반운동 수준에 대해 구조물에 발생하는 변위를 평가할 수 있었고, 기존 구조물의 내진성능에 대한 평가나 신설구조물의 성능목표에 대한 설계검증에 효율적으로 적용 가능하였다.

학교건축물의 내진현황과 내진성능 특성에 관한 연구 (A Study on the Current State of Seismic-Resistance and the Feature of Seismic Performance in School Buildings)

  • 조민주;이주나
    • 교육시설 논문지
    • /
    • 제19권3호
    • /
    • pp.33-40
    • /
    • 2012
  • At present, the problem to secure seismic resistance capacity is one of the most important issue in school buildings. However, the range of facilities to consider retrofit or the proper direction of seismic retrofit haven't provided in details. Therefore in this study, a series of school buildings were chosen as established time, and the structure composition and the seismic performance of the school buildings were investigated to get the comprehensive features of seismic resistance capacity in school buildings. At result, it was presented that the member capacities were less than criteria and structure system was showed the brittle behavior at the collapse prevention level at the school buildings before 1990 year. At the school buildings after 1990 year, though it is hard to get general features for various compositions, it was presented that they have problems for seismic performance evaluation in some buildings at life safety level, specially in the direction of X axis. So, considering the introduction process of seismic criteria in Korea, the school buildings before 2005 year should be examined for seismic resistance capacity and the seismic performance should be examined as well as member capacity to resist seismic.