• Title/Summary/Keyword: Sediment Treatment

Search Result 233, Processing Time 0.028 seconds

Water Quality Improvement of Pocheon Stream Using Freshwater Bivalves: Development and Operation of Continuous Removal of Organic Matter in Streams (S-CROM) (포천천 수질개선을 위한 패류의 이용 하천형 유기물 제어(S-CROM) 기술의 적용)

  • Kim, Baik-Ho;Lee, Ju-Hwan;Kim, Yong-Jae;Hwang, Su-Ok;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.317-330
    • /
    • 2009
  • To diminish the levels of organic matters, a novel S-CROM (continuous removal of organic matters in the stream system using freshwater bivalve), was developed and applied to the polluted stream discharging from the wastewater treatment plant, Pocheon stream, Pocheon city (Korea). Major pollutants of the stream were human population and industrial wastewaters. The study was conducted at a small dam constructed within the stream, often called 'bo', and designed with four tanks; no mussels and no sediment (negative control), no mussels and sediment (positive control), 30 mussels and sediment (D1), and 60 mussels and sediment (D2). Physicochemical and biological parameters were measured at 12 hours interval (day and night) after mussel stocking. Results indicated that Anodonta woodiana Lea (D2) clearly removed approximately 72% of chl-$\alpha$ and 57% of suspended solids on second day, however, there were no differences in removal activities between animal densities (P>0.5). Dislike a laboratory CROM system, which previously developed, there were no huge release of nutrient ($NH_3$-N and SRP), due perhaps to the higher flow rate and the lower animal density. Therefore, we may suggest that if we can determine the relevant current and the animal density considering the stream state, an S-CROM system has a strong potential to water quality improvement of eutrophic streams. Some characteristics on both CROM and S-CROM were compared.

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.

Reduction of the Offensive Odor from Confectionery Wastewater Plant (제과공장의 폐수처리장에서 발생하는 악취 저감)

  • 김영식;손병현;조상원;정종현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

Radioactive iodine analysis in environmental samples around nuclear facilities and sewage treatment plants

  • Lee, UkJae;Kim, Min Ji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1355-1363
    • /
    • 2018
  • Many radionuclides exist in normal environment and artificial radionuclides also can be detected. The radionuclides ($^{131}I$) are widely used for labeling compounds and radiation therapy. In Korea, the radionuclide ($^{131}I$) is produced at the Radioisotope Production Facility (RIPF) at the Korea Atomic Energy Research Institute in Daejeon. The residents around the RIPF assume that $^{131}I$ detected in environmental samples is produced from RIPF. To ensure the safety of the residents, the radioactive concentration of $^{131}I$ near the RIPF was investigated by monitoring environmental samples along the Gap River. The selected geographical places are near the nuclear installation, another possible location for $^{131}I$ detection, and downstream of the Gap River. The first selected places are the "front gate of KAERI", and the "Donghwa bridge". The second selected place is the sewage treatment plant. Therefore, the Wonchon bridge is selected for the upstream of the plant and the sewage treatment plant is selected for the downstream of the plant. The last selected places are the downstream where the two paths converged, which is Yongshin bridge (in front of the cogeneration plant). In these places, environmental samples, including sediment, fish, surface water, and aquatic plants, were collected. In this study, the radioactive iodine ($^{131}I$) detection along the Gap River will be investigated.

A Study on Treatment of CSOs by Vortex Separator and Continuous Fiber-Filter System (Vortex separator와 연속식 섬유사여과를 이용한 CSOs 처리연구)

  • Lee, Bum-Joon;Na, Ji-Hoon;Kim, Jin-Sung;Joo, Jae-Young;Bae, Yoon-Sun;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.443-451
    • /
    • 2010
  • This study was conducted to confirm the CSOs characteristics, and to estimate treatment efficiency of CSO treatment process. Flowrate was average $53,500m^3$/d, maximum $58,100m^3$/d during dry season, but after rain-fall, the flowrate was increased more than twice that of the dry season. And, water pollution concentrations, such as $COD_{Cr}$, SS, $BOD_5$, TN and TP of after rain-fall, were also increased. Thus, for more efficient treatment of pollutants during rainy season, The vortex separator and continuous fiber filter devices were used. From the results on particle range, removal efficiency of particle was 99.7% at the particle size range of $40{\sim}100{\mu}m$ but decreased as 55-80% at the below $40{\mu}m$. The removal efficiencies of $COD_{Cr}$, SS, TN and TP were approx. 70, 60, 70 and 50, respectively during the dry season and approx. 50, 50, 8 and 18% during the rainy season. Also, when compared with the primary sediment basin, $COD_{Cr}$, SS, TN and TP removal efficiencies were high. especially, at the case of TN and TP, TN was more removed than TP because of higher conversion factor value. But we needed more study for the injection of a coagulants to get more stable treatment efficiency for soluble pollutants. Consequently, This process can be used for CSOs treatment as well as replace the primary sedimentation basin during the dry season.

A Laboratory-Scale Study of the Applicability of a Halophilic Sediment Bioelectrochemical System for in situ Reclamation of Water and Sediment in Brackish Aquaculture Ponds: Effects of Operational Conditions on Performance

  • Pham, Hai The;Vu, Phuong Ha;Nguyen, Thuy Thu Thi;Bui, Ha Viet Thi;Tran, Huyen Thanh Thi;Tran, Hanh My;Nguyen, Huy Quang;Kim, Byung Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.10
    • /
    • pp.1607-1623
    • /
    • 2019
  • Sediment bioelectrochemical systems (SBESs) can be integrated into brackish aquaculture ponds for in-situ bioremediation of the pond water and sediment. Such an in-situ system offers advantages including reduced treatment cost, reusability and simple handling. In order to realize such an application potential of the SBES, in this laboratory-scale study we investigated the effect of several controllable and uncontrollable operational factors on the in-situ bioremediation performance of a tank model of a brackish aquaculture pond, into which a SBES was integrated, in comparison with a natural degradation control model. The performance was evaluated in terms of electricity generation by the SBES, Chemical oxygen demand (COD) removal and nitrogen removal of both the tank water and the tank sediment. Real-life conditions of the operational parameters were also experimented to understand the most close-to-practice responses of the system to their changes. Predictable effects of controllable parameters including external resistance and electrode spacing, similar to those reported previously for the BESs, were shown by the results but exceptions were observed. Accordingly, while increasing the electrode spacing reduced the current densities but generally improved COD and nitrogen removal, increasing the external resistance could result in decreased COD removal but also increased nitrogen removal and decreased current densities. However, maximum electricity generation and COD removal efficiency difference of the SBES (versus the control) could be reached with an external resistance of $100{\Omega}$, not with the lowest one of $10{\Omega}$. The effects of uncontrollable parameters such as ambient temperature, salinity and pH of the pond (tank) water were rather unpredictable. Temperatures higher than $35^{\circ}C$ seemed to have more accelaration effect on natural degradation than on bioelectrochemical processes. Changing salinity seriously changed the electricity generation but did not clearly affect the bioremediation performance of the SBES, although at 2.5% salinity the SBES displayed a significantly more efficient removal of nitrogen in the water, compared to the control. Variation of pH to practically extreme levels (5.5 and 8.8) led to increased electricity generations but poorer performances of the SBES (vs. the control) in removing COD and nitrogen. Altogether, the results suggest some distinct responses of the SBES under brackish conditions and imply that COD removal and nitrogen removal in the system are not completely linked to bioelectrochemical processes but electrochemically enriched bacteria can still perform non-bioelectrochemical COD and nitrogen removals more efficiently than natural ones. The results confirm the application potential of the SBES in brackish aquaculture bioremediation and help propose efficient practices to warrant the success of such application in real-life scenarios.

Removal and Growth Inhibition of Red-tide Organisms by Blue-Min Treatment (블루민의 적조생물 제거와 생장저해능)

  • Gwak, Seung-Kuk;Jung, Min-Kyung;Lee, Eun-Ki;Cho, Kyung-Je
    • ALGAE
    • /
    • v.19 no.1
    • /
    • pp.7-14
    • /
    • 2004
  • Blue-Min was initially developed as an adsorbent for harmful gas removal and recently improved to apply to livestock, agriculture and aquaculture as an assistant feed. In the Blue-Min treatment, growth of harmful algae (Cochlodinium polykrikoides and the others causing the red-tide in the ocean) were inhibited below 10% in comparison with control and coagulation removal of harmful alge with Blue-Min treatment was more efficient than that of yellow loess treatment. It would be expected that the Ble-Min can be useful for the extirpator against the red-tide organisms and restrain the toxic algal growth around the fish aquaculture using the assistant feed. Recently, its utility has become to be diverse as it was revealed that aquaculture productivity increase by its application and, in addition, that it improve the water quality or sediment conditions in the aquaculture of Chinese White Shrimp. When Blue-Min was treated with the proper dose, the growth inhibition of Microcystis aeruginosa and lsochrysis galbana, which are typical red-tide organisms in freshwaters and food organisms in aquaculture, respectively, were less than that of marine red-tide organisms, while their growth slightly increased with low concentration treatiment. In addition, polyunsaturated fatty acids (PUFA) content of I. galbana slightly increase with the Blue-Min treatment. Through our research, the Blue-Min has diverse and comples function against various biological organisms and is proved as a biological activator or depressor.

Effects of Oxolinic Acid on Microbial Community under Simulated Marine Fish Farm Environment (해산어 양식환경하의 미생물군집에 대한 옥소린산의 영향)

  • Yoon Duk-Hyun;Kim Mu-Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.2 s.25
    • /
    • pp.89-98
    • /
    • 2006
  • The microbial response after treatment of antibiotics was studied for investigating the resistance pattern under simulated aquaculture environment. A marine microcosm was developed for marine fish farm environment using artificial seawater and sediment. Oxolinic acid, which has been commonly used in aquaculture, was employed for the experiment. Resistance patterns and the changes of microbial community were monitored before. during and after use of oxolinic acid. Vibrionaceae was the dominant bacterial species throughout the experiment, consisting 65-75% of total bacterial number in fish farm environment. However, some gram-positive bacteria, Micrococcos sp. and Bacillus sp. strains in marine farm environment were increased in proportion to their number during the treatment. ETS activity of the bacterial communities in aquaculture environment was reduced to 42-67% during the treatment of oxolinic acid. But recovering trends of bacterial number were also detected immediately after cease of oxolinic acid treatment. Frequent treatment of oxolinic acid under the simulated fish farm environment showed bacterial resistance to increase sharply.

  • PDF

Investigation of Microbial Contamination in Semisulcospira libertine and Evaluation of Its Reduction Effects by Sediment Removal Treatment (다슬기(Semisulcospira libertine)의 미생물 오염도 평가 및 해감 제거공정에 따른 저감화 효과)

  • Choi, Man-Seok;Jun, Eun Bi;Choi, Seungho;Bang, Hyeon-Jo;Park, Shin Young
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.361-366
    • /
    • 2019
  • In this study, microbial contamivation semisulcospira libertine and effect of sedimentation treatment of major bacterial and fungal pathogens were investigated. The total aerobic bacteria, coliforms, Escherichia coli, Staphylococcus aureus, and yeast and mold present in raw and water-dipped Semisulcospira libertine were enumerated using the standard plate count methods on using the standard plate method on potato dextrose agar (PDA), 3M Petrifilm for coliforms / E. coli, 3M Petrifilm for S. aureus, and plate count agar (PCA), respectively. In analysis of microbial contamination of raw Semisulcospira libertine, the total aerobic bacteria, coliforms, and yeast and mold were monitored as 6.40, 2.70, and $6.79{\log}_{10}CFU/g$, respectively. Both E. coli and S. aureus were not detected (detection limit: 10 CFU/g). However, Semisulcospira libertine dipped in ground water for 3 hours had higher contamination levels of all natural indigenous microorganisms than raw Semisulcospira libertine. Especially, E. coli was detected as $2.46{\log}_{10}CFU/g$ in the ground water-dipped Semisulcospira libertine. The total aerobic bacteria in the ground water-dipped Semisulcospira libertine was not significantly reduced (p>0.05) compared to that in the raw Semisulcospira libertine. Moreover, coliforms were significantly increased (p>0.05) in all water-dipped Semisulcospira libertine. Only fungi were slightly reduced (less than 0.2 log) (p>0.05) in the tap water-dipped Semisulcospira libertine by comparison with the raw Semisulcospira libertine. The results of this study suggest that the use of chemical sterilizing agents and other physical methods in the washing stage will be necessary for the microbial reduction in raw Semisulcospira libertine because the use of sediment removal treatment by ground or tap water did not affect the microbiological safety of the raw Semisulcospira libertine.

Spatial Distribution and Residual Consistency Assessment of PBDEs in the Surface Sediment of the Masan Bay (마산만 표층퇴적물 내의 폴리브롬화디페닐에테르(PBDEs)의 공간적 분포 및 오염도평가)

  • We, Sung-Ug;Yoon, Cho-Hee;Min, Byung-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.427-436
    • /
    • 2010
  • A total of 18 surface sediments within the special conservation zone in the Masan Bay were analyzed to investigate the spatial distribution and polluted pathway of polybrominated diphenyl ehters(PBDEs). Twenty-two PBDE congeners were detected and brominated diphenyl ether-209 (BDE-209) among them was predominant. The concentrations of BDE-209 and ${\Sigma}_{21}$PBDEs (sum of 21 PBDE congeners without BDE-209) ranged from 2.32 to 64.2 ng/g and from 0.72 to 8.24 ng/g, respectively. The spatial distribution of both BDE-209 and ${\Sigma}_{21}$PBDEs showed a negative gradient from the inner to the outer Bay, indicating that the source of PBDEs might be mainly located inside the Bay such as streams and an effluent of wastewater treatment plants. It was seemed likely that the major parameters determining levels of PBDEs in the Masan Bay were the distance discharging from their sources as well as the characteristics and movement of sediments due to the flow of sea water.