Application of ozone treatment in cooling water systems for energy and chemical conservation |
Ataei, Abtin
(Graduate School of the Environment and Energy, Science and Research Branch, Islamic Azad University)
Mirsaeed, Morteza Ghazi (Graduate School of the Environment and Energy, Science and Research Branch, Islamic Azad University) Choi, Jun-Ki (Department of Mechanical and Aerospace Engineering, University of Dayton) Lashkarboluki, Reza (Department of Chemical Engineering, Iran University of Science & Technology) |
1 | Alawadhi, E.M. (2011), "Cooling process of water in a horizontal circular enclosure subjected to non- uniform boundary conditions", Energy, 36(1), 586-594. DOI |
2 | Al-Bassam, E. and Maheshwari, G.P. (2011), "A new scheme for cooling tower water conservation in arid-zone countries", Energy, 36(7), 3985-3991. DOI |
3 | ASTM D4412-84 (2009), Standard Test Methods for Sulfate-Reducing Bacteria in Water and Water-Formed Deposits; ASTM International, West Conshohocken, PA, USA. www.astm.org |
4 | ASTM D5465-93 (2012), Standard Practice for Determining Microbial Colony Counts from Waters Analyzed by Plating Methods; ASTM International, West Conshohocken, PA, USA. www.astm.org |
5 | Ataei, A. (2008), "Combined pinch analysis for process industries", Ph.D. Thesis; Science and Research Branch, Islamic Azad University, Tehran, Iran. |
6 | Ataei, A., Panjeshahi, M.H., Parand, R. and Tahouni, N. (2009), "Application of an optimum design water system by regeneration concept and pinch technology for water and energy conservation", J. Appl. Sci., 9, 1847-1858. DOI |
7 | Ataei, A., Gharaie, M., Parand, R. and Panjeshahi, E. (2010), "Application of ozone treatment and pinch technology in cooling water systems design for water and energy conservation", Int. J. Energ. Res., 34, 494-506. DOI |
8 | Boffardi, B.P. (1995), "Water treatments in corrosion tests and standards - Application and interpretation", American Society for Testing and Materials; Philadelphia, PA, USA, 699 p. |
9 | Conner, A. (2005), "Reducing cooling towers cost with the ozone technology", Clean Water Ozone Systems Inc. |
10 | Cortinovis, G.F., Paiva, J.L., Song, T.W. and Pinto, J.M. (2009), "A systemic approach for optimal cooling tower operation", Energ. Convers. Manage., 50(9), 2200-2209. DOI |
11 | Eatom, A.D. (1995), Standard methods for the examination of water and wastewater. |
12 | Eatom, A.D. (2005), Standard methods for the examination of water and wastewater. |
13 | Gaylarde, C.C. and Videla, H.A. (1992), "Biocide action on metal bio films", Proceedings of the Pan-American Congress on Corrosion and Protection, NACE International; Mar del Plata, Argentina, Houston, TX, USA, pp. 371-378. |
14 | Ghazi, M. and Ataei, A. (2014a), "A new design for an automatic wet cooling tower with remote controlled capability", Iranian Patent No. 84442. |
15 | Ghazi, M. and Ataei, A. (2014b), "Continues and remote controlled process for Ozone measurement in cooling towers: A novel approach based on ORP method", Iranian Patent No. 83863. |
16 | Hertrampf, J. (1998), Cooling Water Treatment by a Combination of Ozone and Chemicals, GmbH Krefeld, Germany. |
17 | Heidarinejad, G., Karami, M. and Delfani, S. (2009), "Numerical simulation of counter-flow wet-cooling towers", Int. J. Refrig., 32(5), 996-1002. DOI |
18 | Heikkila, P. and Milosavljevic, N. (2001), "A comprehensive approach to cooling tower design", Appl. Therm. Eng., 21(9), 899-915. DOI |
19 | Historical Standard (1983), ASTM D2688-05 Standard Test Methods for Corrosively of Water in the Absence of Heat Transfer (Weight Loss Methods), Annual Book of ASTM Standards; D2688-05; Volume 03.01, PA, USA. |
20 | Jonnalagadda, S.B. and Nadupalli, S. (2014), "Chlorine dioxide for bleaching, industrial applications and water treatment", Indian Chem. Eng., 56(2), 123-136. DOI |
21 | Kern, D.Q. (1950), Process Heat Transfer: Heat Exchanger Design, New York, NY, USA. |
22 | Panjeshahi, M.H., Ataei, A., Gharaie, M. and Parand, R. (2009), "Optimum design of cooling water systems for energy and water conservation", Chem. Eng. Res. Des., 87, 200-209. DOI |
23 | Ponce-Ortega, J.M., Serna-Gonzalez, M. and Jimenez-Gutierrez, A. (2010), "Optimization model for re-circulating cooling water systems", Comput. Chem. Eng., 34(2), 177-195. DOI |
24 | Putois, T., Guittonneau, S., Chaabna, Z., Viboud, S., Zydowicz, P., Bayle, X. and Fontvieille, D. (2014), "Advanced oxidation processes for disinfection treatment of cooling waters", Ozone-Sci. Eng., 36(5), 440-450. DOI |
25 | Rao, R.V. and Patel, V.K. (2011), "Optimization of mechanical draft counter flow wet-cooling tower using artificial bee colony algorithm", Energ. Convers. Manage., 52(7), 2611-2622. DOI |
26 | Rubio-Castro, E., Serna-Gonzalez, M., Ponce-Ortega, J.M. and El-Halwagi, M.M. (2013), "Synthesis of cooling water systems with multiple cooling towers", Appl. Therm. Eng., 50(1), 957-974. DOI |
27 | Serna-Gonzalez, M., Ponce-Ortega, J.M. and Jimenez-Gutierrez, A. (2010), "MINLP optimization of mechanical draft counter flow wet-cooling towers", Chem. Eng. Res. Des., 88(5), 614-625. DOI |
28 | Strittmatter, R., Yang, B. and Johnson, D.A. (2003), Application of Ozone in Cooling Water Systems, Nalco Chemistry. |
29 | Viera, M.R., Guiamet, P.S., de Melle, M.F.L. and Videla, H.A. (2000), "Use of dissolved ozone for controlling plank tonic and sessile bacteria in industrial cooling systems", Int. Biodeter. Biodeg., 44(4), 201-207. DOI |
30 | Tijing, L.D., Kim, H.Y., Lee, D.H., Kim, C.S. and Cho, Y.I. (2010), "Physical water treatment using RF electric fields for the mitigation of fouling in cooling water", Int. J. Heat Mass Tran., 53(7), 1426-1437. DOI |
31 | U.S. Department of Energy (The Pacific National Laboratory) (1995), Ozone treatment for cooling tower. |