• Title/Summary/Keyword: Security Screening

Search Result 91, Processing Time 0.031 seconds

Implementation of Real-Time Security System by using Dual Camera (이중카메라를 이용한 실시간 도난방지 시스템의 구현)

  • Lee, Kwang-Hyoung;Jung, Young-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.158-164
    • /
    • 2009
  • The real time security system using web camera shall correspond in commensurate with it in real time through classifying moving object and analyzing the behavior. But, as to the detection of moving object in real time image through a camera, it is difficult to detect movement correctly according to the change of unnecessary noises, lighting conditions and screened phenomenon. This paper proposes real time security system by dual camera and ultrasonic sensor, a method of advanced detection in order to detect correct movement of specific object. That is, we could improve the tracing characteristics by using ultrasonic sensor as measurement factor of changed position and verify through experiments that the information interchanged between camera upwards and in front of it have effect on tracing a specific object continuously. The results of the experiment show that recognition rate of object was 97.4% and the correct tracing could be done lastingly in a phenomena of screening object.

Ensuring the Admissibility of Mobile Forensic Evidence in Digital Investigation (모바일 포렌식 증거능력 확보 방안 연구)

  • Eo, Soowoong;Jo, Wooyeon;Lee, Seokjun;Shon, Taeshik
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.1
    • /
    • pp.135-152
    • /
    • 2016
  • Because of the evolution of mobile devices such as smartphone, the necessity of mobile forensics is increasing. In spite of this necessity, the mobile forensics does not fully reflect the characteristic of the mobile device. For this reason, this paper analyzes the legal, institutional, and technical considerations for figuring out facing problems of mobile forensics. Trough this analysis, this study discuss the limits of screening seizure on the mobile device. Also, analyzes and verify the mobile forensic data acquisition methods and tools for ensuring the admissibility of mobile forensic evidence in digital investigation.

Automatic Classification of Department Types and Analysis of Co-Authorship Network: Focusing on Korean Journals in the Computer Field

  • Byungkyu Kim;Beom-Jong You;Min-Woo Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.53-63
    • /
    • 2023
  • The utilization of department information in bibliometric analysis using scientific and technological literature is highly advantageous. In this paper, the department information dataset was built through the screening, data refinement, and classification processing of authors' department type belonging to university institutions appearing in academic journals in the field of science and technology published in Korea, and the automatic classification model based on deep learning was developed using the department information dataset as learning data and verification data. In addition, we analyzed the co-authorship structure and network in the field of computer science using the department information dataset and affiliation information of authors from domestic academic journals. The research resulted in a 98.6% accuracy rate for the automatic classification model using Korean department information. Moreover, the co-authorship patterns of Korean researchers in the computer science and engineering field, along with the characteristics and centralities of the co-author network based on institution type, region, institution, and department type, were identified in detail and visually presented on a map.

System Insecurity - Firewalls

  • Ryu, Youngtae
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2000.05a
    • /
    • pp.171-175
    • /
    • 2000
  • The firewall is normally an intermediate system between the secure internal networks and the less secure external networks. It is intended to keep corporate systems safe from intruders, hackers, and accidental entry into the corporate system. The primary types of firewalls are screening routers, proxy servers, and stateful inspectors. Encryption is another form of firewall protection which is being incorporated along with other firewall methods. Before choosing a firewall architecture, a company must have the right mind set about the threat. The future will see more integration of firewall technologies and the increased use of standards in the industry. It must also determine what are the possible consequences of a breach in security and then develop a system to counter the threat. Additionally, new firewall technologies will address the potential dangers associated with the use of Java applets and Active X-controls on the Internet.

  • PDF

전산망 보호를 위한 방화벽 시스템 고찰

  • 박응기;손기욱;정현철
    • Review of KIISC
    • /
    • v.6 no.2
    • /
    • pp.5-20
    • /
    • 1996
  • 본 고는 인터네트와 내부(로컬) 네트워크 사이에 위치하여 내부 네트워크의 자원 및 중요한 정보를 해커 및 불법 침입자로부터 보호하기 위해서 사용되는 방화벽(Firewall) 시스템에 대해 분석하였다. 방화벽 시스템은 OSI 참조 모델의 계층 3과 계층 4에서 프로토콜 정보에 따라 패킷 필터링을 수행하는 스크리닝 라우터(Screening Router) 와 OSI 참조 모델의 상위 계층에서 트래픽을 허가 및 거절하는 게이트웨이 혹은 proxy로 크게 나눌 수 있다. 이러한 방화벽 시스템들은 인터네트 등의 외부 네트워크와 내부 네트워크 사이에서 네트워크 트래픽을 감시하고, 허가 및 거절하는 역할을 수행한다. 인터네트 등 외부 네트워크에 연결된 내부 네트워크를 보호하기 위해서는 강력한 암호화기법 및 정보보호 서비스를 내부 네트워크의 시스템에 구현하고, 방화벽 시스템을 사용하면 해커 등과 같은 불법 침입자로부터 내부 네트워크의 자원 및 정보를 보다 효율적으로 보호할 수 있다.

  • PDF

Infrared Imaging for Screening Breast Cancer Metastasis Based on Abnormal Temperature Distribution

  • Ovechkin Aleck M.;Yoon Gilwon
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.157-161
    • /
    • 2005
  • Medical infrared imaging is obtained by measuring the self-emitted infrared radiance from the human body. Infrared emission is related to surface temperature and temperature is one of the most important physiological parameters related to health. Though recent applications such as security identification and oriental medicine have provided new fields of biomedical applications, infrared thermography has had ups and downs in its usages in cancer detection. Some of the main difficulties include finding proper applications and efficient diagnostic algorithms. In this study, infrared thermal imaging was used to detect regional metastasis of breast cancer. Our measurements were done for 110 women. From 63 individuals of a Healthy Group and a Benign Breast Disease Group, we developed algorithms for differentiating malignant regional metastasis based on temperature difference and asymmetry of temperature distribution. Testing with 47 cancer patients, we achieved a positive predictive value of $87.5\%$ and a negative predictive value of $95.6\%$. The results were better than for mammogram examination. A proper analysis of infrared imaging proved to be a highly informative and sensitive method for differentiating regional cancer metastasis from normal regions.

Halide Perovskites for X-ray Detection: The Future of Diagnostic Imaging

  • Nam Joong Jeon;Jung Min Cho;Jung-Keun Lee
    • Progress in Medical Physics
    • /
    • v.33 no.2
    • /
    • pp.11-24
    • /
    • 2022
  • X-ray detection has widely been applied in medical diagnostics, security screening, nondestructive testing in the industry, etc. Medical X-ray imaging procedures require digital flat detectors operating with low doses to reduce radiation health risks. Recently, metal halide perovskites (MHPs) have shown great potential in high-performance X-ray detection because of their attractive properties, such as strong X-ray absorption, high mobility-lifetime product, tunable bandgap, low-temperature fabrication, near-unity photoluminescence quantum yields, and fast photoresponse. In this paper, we review and introduce the development status of new perovskite X-ray detectors and imaging, which have emerged as a new promising high-sensitivity X-ray detection technology. We discuss the latest progress and future perspective of MHP-based X-ray detection in medical imaging. Finally, we compare the conventional detection methods with quantum-enhanced detection, pointing out the challenges and perspectives for future research directions toward perovskite-based X-ray applications.

Design and Implementation of an IoT Device for the Effective Screening of Dementia and Mild Cognitive Impairment

  • Kim, Hansoo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.119-126
    • /
    • 2019
  • Korea is rapidly becoming an aging society due to lower birth rate and longer life expectancy. As elderly diseases are of a serious concern, the number of patients with dementia has been increasing significantly. For now, it has become a nationwide problem, as dementia is difficult to manage and requires a lot of social costs. To solve this, an IoT device has been devised that efficiently screens Mild Cognitive Impairment(MCI), the early stage of dementia. To design and implement the device, the latest IoT technology is introduced, the optimized Korean Version of Hasegawa Dementia Scale Revised(K-HDS) is utilized, and convenient service scenario with user-friendly design is applied. As a result, the symptoms of MCI have been screened quickly with convenient operation, which lead to the healthier society by the prevention of dementia.

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

Safety Assessment of Ovarian Cryopreservation and Transplantation in Nude Mice Bearing Human Epithelial Ovarian Cancer

  • Zhu, Gen-Hai;Wang, Sheng-Tan;Yang, Zhao-Xin;Cai, Jun-Hong;Chen, Chun-Ying;Yao, Mao-Zhong;Hong, Lan;He, Guo-Li;Yang, Shu-Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4669-4675
    • /
    • 2012
  • Objective: Nude mice with orthotopic transplantation of human ovarian epithelial cancer were used to investigate screening criteria for paraneoplastic normal ovarian tissue and the security of the freezing and thawing for ovarian tissue transplantation. Methods: Expression of CK-7, CA125, P53, survivin, MMP-2/TIMP-2 in paraneoplastic normal ovarian tissues were detected by RT-PCR as well as immunohistochemistry. The tissues of the groups with all negative indicators of RT-PCR, all negative indicators of immunohistochemistry, negative expression of CK-7, CA125 and survivin, positive expression of CK-7, CA125 and survivin, cancer tissues and normal ovarian tissues of nude mice were used for freezing and thawing transplantation, to analyze overt and occult carcinogenesis rates after transplantation. Results: When all indicators or the main indicators, CK-7, CA125 and survivin, were negative, tumorigenesis did not occur after transplantation. In addition the occult carcinogenesis rate was lower than in the group with positive expression of CK-7, CA125 and survivin (P<0.01). After subcutaneous and orthotopic transplantation of ovarian tissues, rates did not change (P>0.05). There was no statistical significance among rates after transplantation of ovarian tissues which were obtained under different severity conditions (P>0.05). Conclusion: Negative expression of CK-7, CA125 and survivin can be treated as screening criteria for security of ovarian tissues for transplantation. Immunohistochemical methods can be used as the primary detection approach. Both subcutaneous and orthotopic transplantation are safe. The initial severity does not affect the carcinogenesis rate after tissue transplantation. Freezing and thawing ovarian tissue transplantation in nude mice with human epithelial ovarian carcinoma is feasible and safe.