• Title/Summary/Keyword: Secure Monitoring

Search Result 337, Processing Time 0.03 seconds

A Study on the TQM and 6 Sigma Management - Primarily on service industry - (TQM과 6시그마 경영에 관한 고찰 - 서비스산업을 중심으로)

  • 김동훈;장영준
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.120-138
    • /
    • 2002
  • In order to carry out TQM and 6 Sigma management, it is the key elements to make clear a goal and a mission. Above all, we can succeed In achieving a dramatic change and a great outcome only when we make clear the method, incentives, organization and plans under the clear objective. In order to secure the competitiveness against the external challenge, it is essential to keep the several crucial factors such as CEO's will, the systematic process to measure and manage, monitoring to satisfy customer's needs and an aggressive development of TQM activity to encourage the endeavour of the relentless enhancement, and also a positive effort Is to be made for evaluating all quality culture like training experts internally by an outstanding training program under CEO's firm leadership. This study is carried out to understand that which features and factors of success can exist in a company culture if a company accepts a theoretical basis and concept, the general of TQM and 6 Sigma which are one of a management strategy, and carries out TQM and 6 Sigma for achieving improvement of quality and customer's satisfaction.

Study on the Electrical Safety Management Method through the Electrical Characteristic Analysis of LED Lamps (LED 램프의 특성 분석을 통한 전기안전 관리 방안에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Ryu, In-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1931-1936
    • /
    • 2016
  • In this paper, we analyzed causes of accidents that recently increased in the illegal and defective LED lamps. They were analyzed by the electrical characteristics calculation and reappearance experiments. The causes of the accidents were analyzed from the circuit affected by the variation of voltage, current and power by harmonics. We drew a conclusion for electrical safety in illegal or degraded LED lamps from the analysis result. The management factors for electrical safety in LED lamps were harmonics, reactive power and power factor. It is possible to secure the electrical safety through monitoring of power factor in failure products and available in smart meters or smart distribution boards.

The Analysis of Evaluation Items of Korea Green Building Certification Criteria in Office Building - Focusing on the Case Study of Office Building Certificated by GBCC from 2010 to 2012 - (국내 업무시설 부문의 친환경건축물 인증 평가항목 분석 - 2010년~2012년 국내 친환경 인증 업무시설의 사례 분석을 중심으로 -)

  • Kim, Chang-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • Korea Government have carried out various policies to save the Earth environment from global warming and environmental pollution. It has also executed the Green Building Certification Criteria(GBCC) in 2002. The GBCC of office building was executed in 2003 and was revised twice in 2010 and 2011. Concerns about green building construction were quite increasing to keep the building performances sustainable. The aims of this paper is to check the reliability of weighting factors and scoring difficulties in all assessment categories of GBCC and to suggest the amendment direction of the future assessment criteria for green building. For the study, the old and new version of GBCC were examined to present the revision direction of GBCC and the 10 cases certificated by the old and new version, respectively 5 were analysed to compare with the difficulties in obtaining the certification. According to the results of the study, the GBCC requires additional amendments about the assessment categories of the energy consumption monitoring and the building commissioning as required subjects in order to secure the building performances. In addition, the operation mamagement of the building need to be assessed more intensively.

A Study on a Leakage Sensing Pipe and Monitoring System Using TDR in GIS (GIS상에서 TDR을 사용한 누수감지관과 모니터링 시스템에 관한 연구)

  • 강병모;홍인식
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.567-578
    • /
    • 2004
  • GIS technique enhanced a space data manipulation ability and we are offering a geographic information service through various analysis. The quantity used of the water was increased in such situation according to a population increase and a city concentration phenomenon. But, to secure clear water are difficult, owing to the water shortage phenomenon, seepage and the quality of water change for worse. We decide the seepage and the system to retrieve the seepage location using GIS in order to reduce vast loss from the seepage. In this paper we proposed Leakage Sensing System using TDR technology in GIS, constructed a GIS database and pilot system to prove the validity, and simulated it using TDR in GIS.

  • PDF

Development of Polymetallic Nodules in the NE Equatorial Pacific: Past, Present and Future (심해저 망간단괴 개발의 현황과 미래)

  • Chi, Sang Bum;Hong, Sup
    • Ocean and Polar Research
    • /
    • v.36 no.4
    • /
    • pp.367-371
    • /
    • 2014
  • In early 1990s, the Korean government has launched a deep-sea research program to secure the stable long-term supply of strategic metallic minerals including Cr, Cu and Ni. Through the pioneering surveys, Korea registered $150,000km^2$ of Mn-nodule field in the Clarion-Clipperton area, the NE equatorial Pacific to the international sea-bed authority (ISA) in 1994. Following the ISA exploration code, the final exclusive exploration area of $75,000km^2$ was assigned in 2002, based on results of eight-year researches of chemico-physical properties of nodules, bottom profiles and sediment properties. Since that time, environmental studies, mining technical developments including robot miner and lifting system and establishment of smelting systems were accompanied with the detailed geophysical studies to decipher the priori mining area until 2009. Major points of the recent Korea Mn-nodule program are deployed on a commercial scale until 2015. In order to meet the goals, we developed a 1/5 scaled robot miner compared to commercial one in 2012 and performed a mining test at the water depth of 1,370 m in 2013. In addition, detailed 25,000 scaled mining maps in the priori area, which can provide operation roots of the miner, will be prepared and an environmental-friendly mining strategy will be pursued based on the environmental impact test and environmental monitoring.

A Delegation Model based on Agent in Distributed Systems

  • Kim, Kyu-Il;Lee, Joo-Chang;Choi, Won-Gil;Lee, Eun-Ju;Kim, Ung-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.2
    • /
    • pp.82-88
    • /
    • 2007
  • Web services are the new building block of today's Internet, and provides interoperability among heterogeneous distributed systems. Recently in web services environment, security has become one of the most critical issues. The hackers attack one of fragile point and can misuse legitimate user privilege because all of the connected devices provide services for the user control and monitoring in real time. Also, the users of web services must temporarily delegate some or all of their rights to agents in order to perform actions on their behalf. This fact risks the exposure of user privacy information. In this paper, we propose secure delegation model based on SAML that provides confidentiality and integrity about the user information in distributed systems. In order to support privacy protection, service confidentiality, and assertion integrity, encryption and a digital signature mechanism is deployed. We build web service management server based on XACML, in order to manage services and policies of web service providers.

Study on Ground Surface settlement of a 3-Arch-shaped Tunnel (3아치터널의 지표면 침하에 관한 연구)

  • Shin Kang Ho;Park Tu Sung;Park O Sung;Kim Jae Kwon
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1007-1013
    • /
    • 2004
  • A three-arch NATM tunnel with a total length of 53.5m has been constructed for a metropolitan subway station in Daejon, Korea. The tunnel, whose crown is located 22m below the ground, crosses the old Daejon station underneath. Since the tunnel comprises a very large section (10${\times}$28 m; largest in Korea), it shows complicated mechanical behaviors, especially near portal, due to its short length relative to width. As far as its construction step is concerned, the center tunnel is excavated with pre-excavated pilot tunnel, which is a unique feature of this tunnel (first in Korea) to secure safety during construction and prevent excessive settlements. The both side tunnels are then excavated along with the center tunnel. Since significant amount of settlement was predictable from the design stage, extensive monitoring was performed during construction. During excavation of the side tunnels, unexpected large settlements up to ${\~}$140mm (estimated 41.8 mm at design stage) was measured at the center tunnel. In this paper, we study the causes of this unusually large ground settlement. We believe that the extra-wide tunnel excavation increases the stress influence zone of portal in longitudinal direction and consequently add more settlements to the existing due to excavation and consolidation.

  • PDF

A Study on Development of Checklist for Evaluation of School Crime Risks - Focusing on Analysis of CPTED Evaluation Index for School Facilities at Domestic and Foreign - (학교 범죄 위험성 평가를 위한 체크리스트 개발 연구 - 국내·외 학교시설 CPTED 평가지표 분석을 중심으로 -)

  • Hwang, Sung-Eun;Kim, Jin Wook;Yoo, Yong-Heum
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.1
    • /
    • pp.23-32
    • /
    • 2016
  • This research aims to securement of crime prevention for school violence and invasion from outside etc. For crime prevention efficiency secure, It has purpose for school current state comprehension and prevention essential elements deduction autonomously etc. Furthermore, school facility crime dangerousness evaluation checklist is looked for autonomous monitoring tools. This checklist made from analysis of frequency, importance and check availability of 6 native and foreign existing CPTED evaluation's 360 indexes. Then, 81 indexes was derived from analysis, and that indexs verified through focus group interview. Finally, total 47 articles checklist emerged with general details, external school, internal school, and school administrative managements. Through this checklist, school can select essential elements of the preferential crime prevention autonomously, and so it is expected to prompt improvement of crime dangerousness elements, school violence and reduction of crime rate.

The Preventing and Diagnosis of Ultra High Voltage Substation Devices and Combination with An Automation System of A Substation (초고압 변전기기의 예방진단 및 종합 자동화)

  • Yang, Hang-Jun;Kim, Kyung-Geun;Kim, Sung-Sik;You, Jeong-Sik;Kim, Hong-Suk;Lee, Hahk-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.275-277
    • /
    • 2001
  • In this paper a preventative and diagnostic system for high and ultra high voltage electric power transmission apparatus is proposed to secure substation normal operation. The proposed system consists of monitoring sub-system and diagnostic sub-system, which are mainly for GIS and main transformer, and the system will be applied for newly established 765kV class substation in Korea. Some guideline for combination with substation control system are presented, and engineering solution as an improved substation automation system is also proposed.

  • PDF

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF