In this paper, it is fundamental purpose that finding the relationship between quality and structure of bone, by reconstructing the bone structure image, using ultrasound. In this study, longitudinal transmission method was used for experiment as basic measuring method, which is known as ultrasonic diagnosis method for human tibia. And using ultrasonic velocity parameter that can be detected and calculated with the transmitted signal, new estimated parameter, called Bone Area Fraction, is applied to reconstruct image. Through the in-vitro experiment in cattle's tibia bone, basic sectional image of bone which is similar in real bone structure image can be reconstructed.
본 논문은 인체에 무해하며 고분해능의 단층영상과 저가격 및 소형으로 제작이 가능하여 전세계적으로 많은 연구가 진행되고 있는 광영상 단층촬영기(Optical coherence tomography system : OCT)에 관한 것이다. 이러한 OCT시스템은 검출되는 신호가 매우 미약하여 신호처리 및 영상화에 많은 어려움을 가지고 있다. 이러한 문제점을 해결하기 위하여 간섭계의 개선을 통해 신호대 잡음비(Signal to noise ration : SNR)가 향상되도록 하였다. OCT 시스템의 SNR 향상을 위하여 광원의 입력단에 광서큘레이터를 첨가하여 광원부에서 손실되는 단층영상신호를 검출할 수 있도록 간섭계를 개선하였다. SNR 특성평가로는 시뮬레이션을 통한 비교 분석과 기준 샘플의 측정값을 통해 확인하였다. 또한 측정된 데이터의 실시간 영상화를 위한 영상처리 프로그램을 구성하였다. 시뮬레이션 결과로는 개선된 마이켈슨 간섭계가 약 10[dB] 개선됨을 확인하였으며, 기준시편을 이용하여 측정한 결과로는 약 5[dB]가 개선됨을 확인하였다. 개선된 마이켈슨 간섭계를 이용한 OCT 시스템이 보다 높은 대비도로 인해 선명도가 뛰어난 단층을 영상을 얻을 수 있음을 확인 하였다.
본 연구에서는 3차원(3-dimensional, 3D) 프린팅 기술로 출력된 팬톰에 대한 X선 투과성을 평가하고자 하였다. 3D 프린팅 방식은 용융적층조형(fused deposition modeling, FDM) 방식을 이용했으며 소재는 아크릴로나이트릴 뷰타다이엔 스타이렌(acrylonitrile butadiene styrene, ABS)을 사용하였다. 팬톰은 원통 모양으로 설계하였으며 전산화단층영상장비(computed tomography, CT)에서 획득한 단면영상으로 균일도를 측정하였다. X선 투과성 평가는 3D 출력된 팬톰 내부에 이온챔버를 삽입하여 실시하였다. 그 결과, 평균 균일도가 2.70 HU이었으며 기존 폴리메틸 메타크릴레이트(poly methyl methacrylate, PMMA) CT 팬톰과 3D 프린터로 출력된 팬톰에서 측정된 X선 투과성의 상관관계는 0.976로 높은 상관관계가 있는 것으로 나타났다. 향후 3D 프린팅 기술을 이용한 방사선정도관리 팬톰 제작에 기초자료로 활용할 수 있으리라 기대한다.
Direct volume rendering (DVR) is an important 3D visualization method for medical images as it depicts the full volumetric data. However, because DVR renders the whole volume, regions of interests (ROIs) such as a tumor that are embedded within the volume maybe occluded from view. Thus, conventional 2D cross-sectional views are still widely used, while the advantages of the DVR are often neglected. In this study, we propose a new visualization algorithm where we augment the 2D slice of interest (SOI) from an image volume with volumetric information derived from the DVR of the same volume. Our occlusion-based DVR augmentation for SOI (ODAS) uses the occlusion information derived from the voxels in front of the SOI to calculate a depth parameter that controls the amount of DVR visibility which is used to provide 3D spatial cues while not impairing the visibility of the SOI. We outline the capabilities of our ODAS and through a variety of computer tomography (CT) medical image examples, compare it to a conventional fusion of the SOI and the clipped DVR.
This study aimed to examine the relationship between body image satisfaction and breast self-screening behaviors and intentions. The sample for this cross-sectional study consisted of 842 female university students who were recruited from a number of public and private universities. Data were obtained between the months of November and December, 2013, using multistage random cluster sampling. Main research variables were breast cancer screening behavior and intentions, demographic factors, and the total scores on each of the Multidimensional Body-Self Relations Questionnaire (MBSRQ-Appearance Scales) subscales. Results of multivariate analysis showed that having higher satisfaction and more positive evaluation of appearance were related to having performed breast self-examination more frequently in the last year and intending to perform breast self-examination more frequently in the next year. Longitudinal research can potentially provide detailed information about overall body image satisfaction and breast cancer screening behavior among various communities.
In assembly, misalignment must be detected and compensated for during the mating period, regardless of the complexity of the cross-sectional shape. To this end, we propose a novel omnidirectional image sensing system for assembling parts with complicated shapes(OISSA) and its feasibility for detecting the misalignment between mating parts is shown by a series of simulations. This system encompasses a camera with an optical unit attached to the front of the camera. The optical unit consists of a pair of plane mirrors and a pair of conic mirrors. Utilizing the proposed sensing system, a 2$\pi$ coaxial image of the misalignment along the mating boundary interface between mating parts can be immediately obtained without experiencing self-occlusion.
The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.
Clothing shape is principally described in seven factors that are composed of clothing design, clothing material, clothing size, pattern design, sewing method and body motion etc.. The aims of this study was to measurement out-line space-shape variation of clothing fitness with somato type by using the image processing. The subjects for direct anthropometric measurements were 248 female college students aged from 19 to 22. The data were statistically analyzed by principal analysis and cluster analysis. The results were obtained three somato type. Also I made skirts in order to analyzed to the out-line space-shape variation of clothing fitness with body. The effect of somato type on the shape of flare skirts was determined by the out-line space-shape variation of clothing fitness with body. The out-line space-shape variation of clothing fitness with body was observed between the node number and amplitudes of clothing wave form and node number was determined at the maxim of space-shape amplitude, and the space-shape amplitudes have related with aspect ratio of cross-sectional shape. Results for flare skirts show changes in amplitude and mean with fabrics, somato type. therefore gray-level histogram are correlated with changes out-line space-shape, differences in drape spacing and related fabric properties and their somato type. (Korean J Human Ecology 1(2):113∼110 1998)
In this paper the object recognition performance of a photon counting integral imaging system is quantitatively compared with that of a conventional gray scale imaging system. For 3D imaging of objects with a small number of photons, the elemental image set of a 3D scene is obtained using the integral imaging set up. We assume that the elemental image detection follows a Poisson distribution. Computational geometrical ray back propagation algorithm and parametric maximum likelihood estimator are applied to the photon counting elemental image set in order to reconstruct the original 3D scene. To evaluate the photon counting object recognition performance, the normalized correlation peaks between the reconstructed 3D scenes are calculated for the varied and fixed total number of photons in the reconstructed sectional image changing the total number of image channels in the integral imaging system. It is quantitatively illustrated that the recognition performance of the photon counting integral imaging system can be similar to that of a conventional gray scale imaging system as the number of image viewing channels in the photon counting integral imaging (PCII) system is increased up to the threshold point. Also, we present experiments to find the threshold point on the total number of image channels in the PCII system which can guarantee a comparable recognition performance with a gray scale imaging system. To the best of our knowledge, this is the first report on comparisons of object recognition performance with 3D photon counting & gray scale images.
Purpose: The purpose of this study was to identify the levels of body image, sexual intimacy, and sexual satisfaction, and to explore factors affecting sexual intimacy and satisfaction among women within one year of mastectomy. Methods: The present study was a cross-sectional survey and involved 101 women who had undergone mastectomy at a University hospital of D city, Korea. Measurement included the scales of body image, sexual intimacy, and sexual satisfaction. Results: Mean age of the subjects was 51 years. Scores of the body image, sexual intimacy, and sexual satisfaction were 59.62, 90.69, and 69.04, respectively. Body image, sexual intimacy, and sexual satisfaction were significantly related to each other. Sexual intimacy was higher when women were of young age (${\beta}=-.32$), had a shorter period since surgery (${\beta}=-.24$), and with higher levels of body image (${\beta}=.37$). Sexual satisfaction was higher when women had higher levels of body image (${\beta}=.19$) and greater levels of sexual intimacy (${\beta}=.74$). Conclusion: Higher levels of body image and greater levels of sexual intimacy were identified as the significant factors influencing sexual satisfaction among these women. Future research with a mixed-method research is needed to gain a deep understanding of the sexuality between women and their husbands.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.