• Title/Summary/Keyword: Sectional image

Search Result 341, Processing Time 0.023 seconds

Effect of Inorganic Salt Additives on Formation of Phase-Inversion Polyethersulfone Ultrafiltration Membrane (상변환 Polyethersulfone 한외여과막 제조시 무기염 첨가 효과)

  • 김민정;이상덕;염경호
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.75-89
    • /
    • 2002
  • The effect of addition of inorganic salts in polyethersulfone (PES) polymer solution on the membrane formation and ultrafiltartion performance was studied through the thermodynamic and kinetic properties of casting solution. To control the thermodynamic and kinetic properties of casting solution, various inorganic salts $[CaC1_2, LiCl, LiClO_4, ZnC1_2 $and Mg(ClO_4)_2]$ were added in the PES/NMP solution. Variation of membrane morphology and performance of the resulting membranes with change of the salt type and content added in tasting solution were discussed using viscosity, coagulation value, light transmittance measurement, overall membrane porosity, ultrafiltration experiment and cross-sectional SEM image. For all kind of inorganic salts, according as increase of the salt content in casting solution, viscosity is increased, coagulation value becomes lower, top layer thickness below the skin surface is increased, bovine serum albumin(BSA) rejection decreased and pure water flux is increased except $CaC1_2$ and LiCl. In case of $CaC1_2$ and LiCl, it is found that when the salt content is increased, the formation of macrovoids is suppressed and the precipitation rate becomes slow while instantaneous demixing of precipitation type is maintained. However, in case of $LiClO_4$ and $Mg(ClO_4)_2,$ it is found that precipitation rate becomes faster.

Growth of Blue Light Emitting InGaN/GaN MQWs by Metalorganic Chemical Vapor Deposition (유기금속화학기상증착법을 이용한 청색 발광 InGaN/GaN MQWs의 성장에 관한 연구)

  • Kim, Dong-Joon;Moon, Yong-Tae;Song, Keun-Man;Park, Seong-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.11-17
    • /
    • 2000
  • We investigated the growth of InGaN/GaN multiple quantum wells (MQWs) structures which emit blue light. The samples were grown in a low pressure metalorganic chemical vapor deposition system. We examined InGaN/GaN MQWs by varying growth temperatures and thicknesses of InGaN well and GaN barrier layers in MQWs. Especially, the thickness of GaN barrier in InGaN/GaN MQWs was found to severely affect the interfacial abruptness between InGaN well and GaN barrier layers. The higher order satellite peaks in the high resolution x-ray diffraction spectra and the high resolution cross sectional transmission electron microscope image of MQW structrues revealed that the interface between InGaN and GaN layers was very abrupt. Room-temperature photoluminescence spectra also showed a blue emission from InGaN/GaN MQWs at the wavelength of 463.5nm with a narrow full width at half maximum of 72.6meV.

  • PDF

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

The Impact of Corporate's Name Change on Cost of Capital (상호변경이 내재자본비용에 미치는 영향)

  • Yu, Soon-Mi
    • Management & Information Systems Review
    • /
    • v.33 no.4
    • /
    • pp.21-38
    • /
    • 2014
  • This study investigates whether and how a firm's cost of equity is influenced by the extent of a firms's name change. Even though corporate name change doesn't give any benefit to investors, it can be a signaling about firm's future valuation. And also, if that signaling has high credibility, it can be decrease information cost and the firm's cost of equity. on the contrary to this, if corporate name change is kind of break with the past and corporate image laundering, it is bad signaling to investors. So it can be increase information risk and the firm's cost of equity. Using yearly cross-sectional regressions of the cost of equity on our proxies for corporate name change, size, beta, market-to-book ratio and other innate risk factor over the 2005-2010, we find that the cost of capital is positively associated with corporate name change after controlling for all other factors. This result implies that corporate name change increase information risk of the business, and thus increase information asymmetries between managers and outside investors with respect to a firm's true future value. This increases information risk, and creates an adverse selection problem, on the part of outside investors. Rational investors therefore demand a premium for bearing this corporate name change-related information risk, which in turn leads us to observe a positive relation between the intensity of corporate name change and the cost of equity.

  • PDF

Classification of maturation of bacterial dental deposits using differences in fluorescence intensity (형광 차이를 이용한 세균성 치아 침착물의 성숙도 구별)

  • Cho, Mu-Yeol;Lee, Eun-Song;de Jong, Elbert de Josselin;Yoon, Hong-Chul;Kim, Baek-Il
    • The Journal of the Korean dental association
    • /
    • v.57 no.4
    • /
    • pp.213-220
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the red fluorescence characteristics of bacterial dental deposits assessed by quantitative light-induced fluorescence (QLF) technology and confirm whether the red fluorescence can distinguish and evaluate quantitatively accumulation of bacterial dental deposits. Methods: This retrospective cross-sectional study used QLF images captured at a dental clinic from January to December 2016. In each QLF image, a skilled examiner selected one region where the presence of deposits was suspected. Then, the regions were classified into three groups of not detectable deposits(ND), half detectable deposits (HD), and full detectable deposits (FD) by two examiners according to classification criteria. Only those images where the regions of bacterial dental deposits were classified identically by all examiners were used for analysis. The mean red fluorescence intensity (RFI) was defined as the mean value of R/G for all pixels in the regions. The RFI was compared between groups using Welch's ANOVA test, and the Spearman correlation was calculated to assess the association between RFI and accumulation of deposits. Results: In this study, 351 images among the collected images of 605 subjects were finally selected. The mean age of subjects was about 44 years. The R/G values of the ND, HD and FD were 0.73, 1.26 and 1.83 respectively. There were significant differences between all groups (p<0.001), and strong positive correlation was identified between the R/G value and the accumulation of deposits (r = 0.90, p<0.001). Conclusion: The intensity of red fluorescence as observed in the QLF images correlated well with the accumulation maturation of the deposits, which indicates that the QLF technology can be used to evaluate the status of oral hygiene.

  • PDF

Carbon diffusion behavior and mechanical properties of carbon-doped TiZrN coatings by laser carburization (레이저 침탄된 TiZrN 코팅에서 탄소확산거동과 기계적 특성)

  • Yoo, Hyunjo;Kim, Taewoo;Kim, Seonghoon;Jo, Ilguk;Lee, Heesoo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.1
    • /
    • pp.32-36
    • /
    • 2021
  • This study was investigated in carbon diffusion behavior of laser-carburized TiZrN coating layer and the changes of mechanical properties. The carbon paste was deposited on TiZrN coatings, and the laser was irradiated to carburize into the coatings. The XRD peak corresponding to the (111) plane shifted to a lower angle after the carburization, showing the lattice expansion by doped carbon. The decreased grain size implied the compression by the grain boundary diffusion of carbon. The XPS spectra for the bonding states of carbon was analyzed that carbon was substitute to nitrogen atoms in TiZrN, as carbide, through the thermal energy of laser. In addition, the combination of sp2 and sp3 hybridized bonds represented the formation of an amorphous carbon. The cross-sectional TEM image and the inverse FFT of the TiZrN coating after carburizing were observed as the wavy shape, confirming the amorphous phase located in grain boundaries. After the carburization, the hardness increased from 34.57 GPa to 38.24 GPa, and the friction coefficient decreased by 83 %. In particular, the ratio of hardness and elastic modulus (H/E) which is used as an index of the elastic recovery, increased from 0.11 to 0.15 and the wear rate improved by 65 %.

Enhancement of Geomorphology Generation for the Front Land of Levee Using Aerial Photograph (항공영상을 연계한 하천 제외지의 지형분석 개선 기법)

  • Lee, Geun Sang;Lee, Hyun Seok;Hwang, Eui Ho;Koh, Deuk Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.407-415
    • /
    • 2008
  • This study presents the methodology to link with aerial photos for advancing the accuracy of topographic survey data that is used to calculate water volume in urban stream. First, GIS spatial interpolation technique as Inverse Distance Weight (IDW) and Kriging was applied to construct the terrain morphology to the sand-bar and grass area using cross-sectional survey data, and also validation point data was used to estimate the accuracy of created topographic data. As the result of comparison, IDW ($d^{-2}_{ij}$, 2nd square number) in Sand-bar area and Kriging Spherical model in grass area showed more efficient results in the construction of topographic data of river boundary. But the differences among interpolation methods are very slight. Image classification method, Minimum Distance Method (MDM) was applied to extract sand-bar and grass area that are located to river boundary efficiently and the elevation value of extracted layers was allocated to the water level point value. Water volume with topographic data from aerial photos shows the advanced accuracy of 13% (in sand-bar) and 12% (in grass) compared to the water volume of original terrain data. Therefore, terrain analysis method in river linking with aerial photos is efficient to the monitoring about sand-bar and grass area that are located in the downstream of Dam in flooding season, and also it can be applied to calculate water volume efficiently.

Predictors of Burnout among Staff in Long-term Care Facilities for the Elderly (노인장기요양보호 인력의 소진 예측 요인)

  • Lee, Choo-Jae
    • 한국노년학
    • /
    • v.31 no.1
    • /
    • pp.97-109
    • /
    • 2011
  • The purpose of this work is to examine how work stressors are related to the burnout among staff in long-term care facilities for the elderly. This study offers some responses to a growing stress and burnout for the long-term care workers. The demand for long-term care workers is set to rise in light of an increasing share of older people and dependent elderly. Long-term care workers provide long-term care services to persons with a reduced degree of functional, physical or cognitive capacity. Cross-sectional survey data were collected from 216 staff in long-term care facilities. The standardised Maslach Burnout Inventory(MBI) was used to assess levels of burnout in long-term care workers. The MBI consists of 22 items using a 5-point Likert scale, measuring three sub-scales of burnout; Emotional exhaustion, Depersonalization, and Personal accomplishment. Data were analyzed using regression. This study is empirically tested the degree of association between burnout and its antecedents. The majority of differences in burnout could be explained by work stressors such as client relationship, job overload, job role conflict, and conflicts with clients' family. The study also identified workers' perceptions of their image in society and emotional support as predictors of burnout. Therefore long-term care facilities are encouraged to review their practices so that workers well-being is supported. The study findings suggest attention for organizational oriented initiatives to cope with burnout.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia

  • Jang-Hoon Oh;Bo Guem Choi;Hak Young Rhee;Jin San Lee;Kyung Mi Lee;Soonchan Park;Ah Rang Cho;Chang-Woo Ryu;Key Chung Park;Eui Jong Kim;Geon-Ho Jahng
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.770-781
    • /
    • 2021
  • Objective: Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia. Materials and Methods: Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTRasym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves. Results: Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTRasym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTRasym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91. Conclusion: CEST MRI potentially allows noninvasive image alterations in the Alzheimer's disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.