• Title/Summary/Keyword: Sectional image

Search Result 344, Processing Time 0.029 seconds

Quality of Life among Breast Cancer Patients In Malaysia

  • Ganesh, Sri;Lye, Munn-Sann;Lau, Fen Nee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1677-1684
    • /
    • 2016
  • Background: Among the factors reported to determine the quality of life of breast cancer patients are socio-demographic background, clinical stage, type of treatment received, and the duration since diagnosis. Objective: The objective of this study was to determine the quality of life (QOL) scores among breast cancer patients at a Malaysian public hospital. Materials and Methods: This cross-sectional study of breast cancer patients was conducted between March to June 2013. QOL scores were determined using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) and its breast cancer supplementary measure (QLQ-BR23). Both the QLQ-C30 and QLQ-BR23 assess items from functional and symptom scales. The QLQ-C30 in addition also measures the Global Health Status (GHS). Systematic random sampling was used to recruit patients. Results: 223 breast cancer patients were recruited with a response rate of 92.1%. The mean age of the patients was 52.4 years (95% CI = 51.0, 53.7, SD=10.3). Majority of respondents are Malays (60.5%), followed by Chinese (19.3%), Indians (18.4%), and others (1.8%). More than 50% of respondents are at stage III and stage IV of malignancy. The mean Global Health Status was 65.7 (SD = 21.4). From the QLQ-C30, the mean score in the functioning scale was highest for 'cognitive functioning' (84.1, SD=18.0), while the mean score in the symptom scale was highest for 'financial difficulties' (40.1, SD=31.6). From the QLQ-BR23, the mean score for functioning scale was highest for 'body image' (80.0, SD=24.6) while the mean score in the symptom scale was highest for 'upset by hair loss' (36.2, SD=29.4). Two significant predictors for Global Health Status were age and employment. The predictors explained 10.6% of the variation of global health status ($R^2=0.106$). Conclusions: Age and employment were found to be significant predictors for Global Health Status (GHS). The Quality of Life among breast cancer patients reflected by the GHS improves as age and employment increases.

Geometry and Property Database for Korean Spine Research (한국인 척추 연구를 위한 형상 / 물성 정보 구축)

  • Lee, Seung-Bock;Lee, Sang-Ho;Han, Seung-Ho;Kwak, Dai-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.488-493
    • /
    • 2011
  • The Korean spine geometry and property data for researchers were made by KISTI and Catholic Institute for Applied Anatomy. We took whole spine CT, X-Ray, BMD scan for making high resolution cross-sectional spine images using more 20 donated cadavers(60 - 80 years). Then we constructed 3-dimensional volume model using serial CT images by Mimics software. The major morphometric parameters of vertebrae were measured. Mechanical motion and property data were obtained by the same cadavers using the DEXA for BMD and the spine simulator. The Korean spine geometry and property data could be used for research and development of medical device.

Development of capacitive Micromachined Ultrasonic Transducer (III) - Performance Test (미세가공 정전용량형 초음파 탐촉자 개발(III) - 탐촉자 성능평가)

  • Kim, Ki-Bok;Ahn, Bong-Young;Park, Hae-Won;Kim, Young-Joo;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.581-589
    • /
    • 2004
  • In this study, the capacitive micromachined ultrasonic transducer(cMUT) was developed based on the previous research results. The cross sectional image of the developed cMUT was characterized. To measure the membrane displacement of the cMUT, the Michelson phase modulation fiber interferometer was constructed. The measured membrane displacement was in good agreement with the result of the finite element analysis. To estimate the ultrasonic wave generated by the cMUT, an ultrasonic system including a pulser, receiver and charge amplifier was used. The cMUT developed in this study shows a good performance and hence will be widely used in the non-contact ultrasonic applications.

Effect of Applied Current Density on the Corrosion Damage of Steel with Accelerated Electrochemical Test (전기화학적 가속 부식 평가법에서 강재의 부식 손상에 미치는 인가전류밀도의 영향)

  • Lee, Jung-Hyung;Park, Il-Cho;Park, Jae-Cheul;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.5
    • /
    • pp.423-430
    • /
    • 2016
  • In this study, we investigated the corrosion damage characteristics of steel for offshore wind turbine tower substructure using an accelerated electrochemical test. The galvanostatic corrosion test method was employed with a conventional 3 electrode cell in natural sea water, and the steel specimen was served as a working electrode to induce corrosion in an accelerated manner. Surface and cross-sectional image of the damaged area were obtained by optical microscope and scanning electron microscope. The weight of the specimens was measured to determine the gravimetric change before and after corrosion test. The result revealed that the steel tended to suffer uniform corrosion rather than localized corrosion due to active dissolution reaction under the constant current regime. With increasing galvanostatic current density, the damage depth and surface roughness of surface was increased, showing approximately 25 times difference in damage depth between the lowest current density ($1mA/cm^2$) and the highest current density ($200mA/cm^2$). The gravimetric observation showed that the weight loss was proportionally increased with increment of current density that has 75 times different according by experimental conditions. Consequently, uniform corrosion of the steel specimen was conveniently induced by the electrochemically accelerated corrosion technique, and it was possible to control the extent of the corrosion damage by varying the current density.

EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE (수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향)

  • Lee, Cheol-Hwan;Cho, Kyung-Mo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

Characteristics of Indium Doped SnO2 Thick Film for Gas Sensors (Indium 첨가된 SnO2 후막형 가스센서의 특성)

  • Yu, Il;Lee, Ji-Young
    • Korean Journal of Materials Research
    • /
    • v.20 no.8
    • /
    • pp.408-411
    • /
    • 2010
  • Indium doped $SnO_2$ thick films for gas sensors were fabricated by a screen printing method on alumina substrates. The effects of indium concentration on the structural and morphological properties of the $SnO_2$ were investigated by X-ray diffraction and Scanning Electron Microscope. The structural properties of the $SnO_2$:In by X-ray diffraction showed a (110) dominant $SnO_2$ peak. The size of $SnO_2$ particles ranged from 0.05 to $0.1\;{\mu}m$, and $SnO_2$ particles were found to contain many pores, according to the SEM analysis. The thickness of the indium-doped $SnO_2$ thick films for gas sensors was about $20\;{\mu}m$, as confirmed by cross sectional SEM image. Sensitivity of the $SnO_2$:In gas sensor to 2000 ppm of $CO_2$ gas and 50 ppm of H2S gas was investigated for various indium concentrations. The highest sensitivity to $CO_2$ gas and H2S gas of the indium-doped $SnO_2$ thick films was observed at the 8 wt% and 4 wt% indium concentration, respectively. The good sensing performances of indium-doped $SnO_2$ gas sensors to $CO_2$ gas were attributed to the increase of oxygen vacancies and surface area in the $SnO_2$:In. The $SnO_2$:In gas sensors showed good selectivity to $CO_2$ gas.

Evaluation of Skin Texture and Wrinkle Using Optical Coherence Tomography (Pilot Study) (피부결 및 주름 평가에 있어 광학단층영상술(Optical Coherence Tomography, OCT) 활용 연구(Pilot Study))

  • Kim, Seunghun;Ahn, Yujin;Sanzhar, Askaruly;Kim, Pilun;Jung, Woonggyu;Lee, Haekwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.3
    • /
    • pp.247-254
    • /
    • 2017
  • Optical Coherence Tomography (OCT) is a non-invasive imaging method that utilizes the optical scattering and interference for visualizing the surface as well as cross-sectional structures of tissue. OCT has been used for diagnosing diseases in early stage in various medical fields, but an application in cosmetics is still at early stage. In this study, OCT was adopted to evaluate skin texture and wrinkle. Results showed similar patterns of evaluation with PRIMOS in the assessment using replica. In addition, OCT produced smaller errors at different angles compared to the PRIMOS in the assessment using 3-dimensional models of wrinkles. The resolution of the image was also high enough to differentiate the images of before and after the application of makeup products. Possible use of OCT in the evaluation of fine wrinkle assessment was studied in this research. Further development of methods is necessary to provide more evidences of the effectiveness.

The changes of rectus abdominis muscle thickness according to the angle during active straight leg raise

  • Lee, Hwang Jae;Shin, Kil Ho;Byun, Sung Mi;Jeong, Hyeon Seo;Hong, Ji Su;Jeong, Su Ji;Lee, Wan Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.44-48
    • /
    • 2013
  • Objective: The purpose of this study was to investigate changes of abdominal muscles thickness according to the angle during the active straight leg raise (ASLR) in young healthy subjects. Design: Cross sectional study. Methods: Twenty-three healthy university students (13 men and 10 women) voluntary participated to the study in S University. The ASLR was performed with the subject lying supine with lower extremities straight on a standard plinth, hands resting on the chest, and elbows on the plinth. When one subject performed ASLR from each angles ($30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$), compared changes in the thickness of rectus abdominis muscle. Changes in muscle thickness during ASLR test were assessed with ultrasonography. All subjects were to provide enough time of rest after performed ASLR. Rectus abdominis thickness were measured using rehabilitative ultrasound image. Results: Good quality rectus abdominal muscle activation data were recorded during ASLR. The length changes of linea alba showed significantly shorter in between $0^{\circ}$ and $30^{\circ}$ (p<0.05). The thickness of rectus abdominis muscle were significantly different between $0^{\circ}$ and $30^{\circ}$, $0^{\circ}$ and $45^{\circ}$, $0^{\circ}$ and $60^{\circ}$, $0^{\circ}$ and $90^{\circ}$. According to increase of pelvic angle, the thickness of rectus abdominis muscle were more thickening (p<0.05). Conclusions: This result is changes of abdominal muscles thickness according to the angle during the ASLR.

  • PDF

Diagnostic values of abdominal muscles thickness and sterno-costal angle for young adults with rounded shoulders

  • Lee, Chan-hee;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2020
  • Objective: The purposes of this study was to evaluate the diagnostic values of abdominal muscles thickness and sterno-costal angle as the quantitative diagnostic indicators for young adults with rounded shoulders. Design: A observational, cross-sectional study. Methods: This study included thirty-three male participants in order to examine the relationship among thoracic kyphosis, sternocostal angle, and abdominal muscle thickness. We used ultrasound imaging to measure the muscle thickness, two gravity-dependent inclinometers to measure the kyphosis angle, and Image J to measure the sterno-costal angle. Results: There was a significant positive correlation between the amount of thoracic kyphosis angle and muscle thickness of the external oblique (EO) on the right side (r=0.931), and on the left side (r=0.432), and the transverse abdominis (TrA) (r=0.649). There was also a significant negative correlation between the thoracic kyphosis angle and the sterno-costal angle at the right side (r=-0.942) and at the left side (r=-0.860). There was a significant positive relationship with muscle thickness of the EO and TrA on the right side with the thoracic kyphosis angle, and was significant negative relationship with the sterno-costal angle on both sides. Conclusions: The results of the study suggest that the thoracic kyphosis angle is related to muscle thickness of the EO and TrA on the dominant side and the sterno-costal angle. We also suggest that future studies are needed to determine how strengthening the abdominal muscles may contribute to preventing excessive thoracic kyphosis in young adults.

Crystalline Properties of GaN Layers Grown on PSS and AlN Buffered PSS by HVPE Method (HVPE법을 이용하여 PSS와 AlN Buffered PSS 위에 성장시킨 GaN 박막의 결정 특성)

  • Lee, Won Jun;Park, Mi Seon;Lee, Won Jae;Kim, Il Su;Choi, Young Jun;Lee, Hae Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.386-391
    • /
    • 2018
  • An epitaxial GaN layer was grown on a cone-shape-patterned sapphire substrate (PSS) (Sample A) and an AlN-buffered PSS (Sample B) with two growth steps under the same process conditions by employing the hydride vapor phase epitaxy (HVPE) method. We have investigated the characteristics of the GaN layer grown on two kinds of substrates at each growth step. The cross-sectional SEM image of the GaN layer grown on the two types of substrates showed growth states of GaN layers formed during the 1st and 2nd growth steps with different growth durations. Dislocation density was obtained by calculation using the FWHM value of the rocking curve for (002) and (102). Sample A showed 2.62+08E and 6.66+08E and sample B exhibited 5.74+07E and 1.65+08E for two different planes. The red shift was observed is photoluminescence (PL) analysis and Raman spectroscopy results. GaN layers grown on AlN-buffered PSS exhibited better optical and crystallographic properties than GaN layers grown on PSS.