• Title/Summary/Keyword: Sectional image

Search Result 339, Processing Time 0.028 seconds

Barriers to Access Formal Financial Services: An Empirical Study from Indonesia

  • JAYANTI, Ari Dwi;AGUSTI, Kemala Sari;SETIYAWATI, Yuli
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.11
    • /
    • pp.97-106
    • /
    • 2021
  • The condition of financial services in Indonesia is unique, based on various characteristics, behaviors, and preferences. Therefore, the study of finance and banking is interesting to study as a recommendation for government policies. This paper aims to analyze the barriers to accessing formal financial services in Indonesia and why informal financial services are preferred. This paper presents a case study of financial inclusion in selected provinces in Indonesia using the SOFIA dataset from the Ministry of National Development Planning. Overall, this data consists of 20,000 individuals from 4 provinces and 93 regions representing the population in eastern Indonesia. The analysis was carried out by processing individual-level cross-sectional data surveyed in 2017 using the probit binary logistic method. The results identify the individual barriers in accessing formal financial services, including account ownership, saving, and credit activities in the formal financial institutions, and amplify the image by analyzing what determinants affect people to choose informal institutions. We found that some individual characteristics such as age, gender, education, income, employment status, residence, and access to technology significantly affect the barrier to formal financial services in East Indonesia.

Bi-Te Core/Shell Nanowires Synthesis Based on On-Film Formation of Nanowires Method for Thermoelectric Applications (압축응력에 의한 박막 위 나노선 성장법을 이용한 Bi-Te 코어/쉘 열전 나노선 합성)

  • Kang, Joohoon;Ham, Jinhee;Roh, Jong Wook;Noh, Jin-Seo;Lee, Wooyoung
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.5
    • /
    • pp.445-448
    • /
    • 2010
  • For an enhanced thermoelectric performance, one-dimensional heterostructure nanowires were created that consisted of aBi core and Te shell. The structure was fabricated by depositing Te in-situ onto a Bi nanowire grown by our unique OFF-ON (on-film formation of nanowires) method. After examining a cross-sectional TEM image, it was found that diffusive interface was formed between Bi and Te. Selected area electron diffraction revealed that the crystallinity of the Te shell was some what lower compared to the highly single-crystalline Bi core. The Bi-Te core/shell nanowires can be a smart structure that suppresses phonon transport by several scattering mechanisms, making the OFF-ON method the simplest way to realize that structure.

Effect of Electrical Muscle Stimulation Belt for Abdominal Muscles Activation

  • Choi, Dayeong;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2021
  • Objective: The purpose of this study is to observe the change in the thickness of abdominal muscles when electrical muscle stimulation (EMS) is applied to the abdomen during rest and abdominal muscle exercise to investigate the effect of EMS applied to the abdomen on the superficial and deep muscles thickness. Design: Cross sectional design. Methods: Twenty healthy subjects participated in this study. Subjects were performed resting position, resting position with EMS, curl-up and curl-up with EMS. The electrode of the EMS belt is attached to the abdominal wall between the 12th rib and iliac crest. The thickness of abdominal muscles including rectus abdominis (RA), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were captured in each position by ultrasound image during expiration. All subjects were performed four positions randomly. Data were analyzed using repeated ANOVA with the level of significance set at 𝛼=0.05. Results: The muscle thickness of RA, EO, IO and TrA were significantly different at each position (p<0.05). The thickness of all abdominal muscles increased significantly when curl-up than curl-up with EMS. Both RA and EO thickness were significantly increased at resting position than resting position and EMS were combined(p<0.05). But IO and TrA thickness were decreased at resting position when EMS were combined. Conclusions: The results suggest that EMS activates superficial abdominal muscles RA and EO. Therefore, abdominal strengthening exercise combined EMS can activate abdominal muscles and can be applied to various patients and rehabilitation in clinical practice.

Association between Socioeconomic Status and Altered Appearance Distress, Body Image, and Quality of Life Among Breast Cancer Patients

  • Chang, Oliver;Choi, Eun-Kyung;Kim, Im-Ryung;Nam, Seok-Jin;Lee, Jeong Eon;Lee, Se Kyung;Im, Young-Hyuck;Park, Yeon Hee;Cho, Juhee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8607-8612
    • /
    • 2014
  • Background: Breast cancer patients experience a variety of altered appearance - such as loss or disfigurement of breasts, discolored skin, and hair loss - which result in psychological distress that affect their quality of life. This study aims to evaluate the impact of socioeconomic status on the altered appearance distress, body image, and quality of life among Korean breast cancer patients. Materials and Methods: A cross-sectional survey was conducted at advocacy events held at 16 different hospitals in Korea. Subjects were eligible to participate if they were 18 years of age or older, had a histologically confirmed diagnosis of breast cancer, had no evidence of recurrence or metastasis, and had no psychological problems at the time of the survey. Employment status, marital status, education, and income were assessed for patient socioeconomic status. Altered appearance distress was measured using the NCI's cancer treatment side effects scale; body image and quality of life were measured by the EORTC QLC-C30 and BR23. Means and standard deviations of each outcome were compared by socioeconomic status and multivariate linear regression models for evaluating the association between socioeconomic status and altered appearance distress, body image, and quality of life. Results: A total of 126 breast cancer patients participated in the study; the mean age of participants was 47.7 (SD=8.4). Of the total, 83.2% were married, 85.6% received more than high school education, 35.2% were employed, and 41% had more than $3000 in monthly household income. About 46% had mastectomy, and over 30% were receiving either chemotherapy or radiation therapy at the time of the survey. With fully adjusted models, the employed patients had significantly higher altered appearance distress (1.80 vs 1.48; p<0.05) and poorer body image (36.63 vs 51.69; p<0.05) compared to the patients who were unemployed. Higher education (10.58, standard error (SE)=7.63) and family income (12.88, SE=5.08) was positively associated with better body image after adjusting for age, disease stage at diagnosis, current treatment status, and breast surgery type. Similarly, patients who were married and who had higher education had better quality of life were statistically significant in the multivariate models. Conclusions: Socioeconomic status is significantly associated with altered appearance distress, body image, and quality of life in Korean women with breast cancer. Patients who suffer from altered appearance distress or lower body image are much more likely to experience psychosocial, physical, and functional problems than women who do not, therefore health care providers should be aware of the changes and distresses that these breast cancer patients go through and provide specific information and psychosocial support to socioeconomically more vulnerable patients.

A Study of Data Management Methods through Shake Correction of Underwater Investigation Using High Resolution Side Scan SONAR (흔들림 보정을 통한 고해상 사이드스캔소나의 데이터 관리기법 연구)

  • Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul;Choi, Sang-Sik;Lee, Heung-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.94-100
    • /
    • 2017
  • In the case of the side scan sonar operated by the towing method, the underwater structure electric jig was developed because there is a difficulty in the cross-sectional survey that the user wants when conducting the survey. However, in the case of the sound wave photographing method using the electric jig, since the boat and the sonar behaves as one body, data distortion has occurred due to various problems according to working environment, such as, the rolling phenomenon of the boat due to the wave and the fluctuation of the sonic image due to the inoperability of the boat driver. Therefore, in order to solve the image blurring caused by the operation of the equipment for underwater survey of the existing side scan sonar, in this research, the program was supplemented to enable the shake correction by attaching the shake correction sensor and developing the shake correction algorithm. In order to verify the improvement of the sonar data resolution, the sonic images before and after the shake correction were collected through on-site investigation and the analysis of the sonic image data acquired by a diver measuring the actual damage length and depth. This study is expected to contribute to the development of sonar imaging technique of the underwater surface of the structure and bed surface of the sea or a river using the side scan sonar in the future.

The Combined Effect of Subjective Body Image and Body Mass Index (Distorted Body Weight Perception) on Suicidal Ideation

  • Shin, Jaeyong;Choi, Young;Han, Kyu-Tae;Cheon, Sung-Youn;Kim, Jae-Hyun;Lee, Sang Gyu;Park, Eun-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.2
    • /
    • pp.94-104
    • /
    • 2015
  • Objectives: Mental health disorders and suicide are an important and growing public health concern in Korea. Evidence has shown that both globally and in Korea, obesity is associated with an increased risk of developing some psychiatric disorders. Therefore, we examined the association between distorted body weight perception (BWP) and suicidal ideation. Methods: Data were obtained from the 2007-2012 Korea National Health and Nutritional Evaluation Survey (KNHANES), an annual cross-sectional nationwide survey that included 14 276 men and 19 428 women. Multiple logistic regression analyses were conducted to investigate the associations between nine BWP categories, which combined body image (BI) and body mass index (BMI) categories, and suicidal ideation. Moreover, the fitness of our models was verified using the Akaike information criterion. Results: Consistent with previous studies, suicidal ideation was associated with marital status, household income, education level, and perceived health status in both genders. Only women were significantly more likely to have distorted BWP; there was no relationship among men. In category B1 (low BMI and normal BI), women (odds ratio [OR], 2.25; 95% confidence interval [CI], 1.48 to 3.42) were more likely to express suicidal ideation than women in category B2 (normal BMI and normal BI) were. Women in overweight BWP category C2 (normal BMI and fat BI) also had an increased OR for suicidal ideation (OR, 2.25; 95% CI, 1.48 to 3.42). Those in normal BWP categories were not likely to have suicidal ideation. Among women in the underweight BWP categories, only the OR for those in category A2 (normal BMI and thin BI) was significant (OR, 1.34; 95% CI, 1.13 to 1.59). Conclusions: Distorted BWP should be considered an important factor in the prevention of suicide and for the improvement of mental health among Korean adults, especially Korean women with distorted BWPs.

Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis (기도협착 측정을 위한 내시경 광 결맞음 단층촬영법을 이용한 3차원 이미징)

  • Kwon, Daa young;Oak, Chulho;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.243-248
    • /
    • 2019
  • The respiratory tract is an essential part of the respiratory system involved in the process of respiration. However, if stenosis occurs, it interferes with breathing and can even lead to death. Asthma is a typical example of a reversible cause of airway narrowing, and the number of patients suffering from acute exacerbation is steadily increasing. Therefore, it is important to detect airway narrowing early and prevent the patient's condition from worsening. Optical coherence tomography (OCT), which has high resolution, is suitable for observing the microstructure of tissues. In this study we developed an endoscopic OCT system. We combined a 1300-nm OCT system with a servo motor, which can rotate at a high speed. A catheter was pulled back using a linear stage while imaging with 360° rotation by the motor. The motor was selected considering various requirements, such as torque, rotational speed, and gear ratio of pulleys. An ex vivo rabbit tracheal model was used as a sample, and the sample and catheter were immobilized by acrylic structures. The OCT images provided information about the structures of the mucosa and submucosa. The difference between normal and stenosed parts in the trachea was confirmed by OCT. Furthermore, through a three-dimensional (3-D) reconstruction process, it was possible to identify and diagnose the stenosis in the 3-D image of the airway, as well as the cross-sectional image. This study would be useful not only for diagnosing airway stenosis, but also for realizing 3-D imaging.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep (수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과)

  • Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.110-115
    • /
    • 1999
  • Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

  • PDF

Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study (rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study)

  • Lee, Woo-Sung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man;Park, Yoon-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • Purpose: This preliminary rabbit study was conducted to evaluate the effect of recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/poly lactic-co-glycolic acid (PLGA) coating on osseointegration of the titanium (Ti) implant. Materials and methods: Eight Ti implants were anodized with 300 voltages for three minutes. Four of those were coated with rhTGF-${\beta}2$/PLGA by an electrospray method as the experimental group. The implants were placed into tibiae of four New Zealand rabbits, two implants per a tibia, one implant per each group. After 3 and 6 weeks, every two rabbits were sacrificed and micro-computed tomography (microCT) was taken for histomorphometric analysis. Results: In scanning electron microscope (SEM) image, the surface of rhTGF-${\beta}2$/PLGA coated Ti implant showed well distributed particles. Although statistically insignificant, microCT analysis showed that experimental group has higher bone volume / total volume (BV/TV) and trabecular thickness (Tb.Th) values relatively. Cross sectional view also showed more newly formed bone in the experimental group. Conclusion: In the limitation of this study, rhTGF-${\beta}2$/PLGA particles coating on the Ti implant show the possibility of more favorable quantity of newly formed bone after implant installation.