• Title/Summary/Keyword: Secondary dam

Search Result 22, Processing Time 0.027 seconds

Long-term Performance of Secondary dam Installed for Water Purification of Reservoir (호소의 수질개선을 위하여 설치한 부댐의 장기간 성능평가)

  • Kim, Bong-Kyun;Park, Jun-Seok;Won, Hee-Jae;Kim, Yun-Yung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.668-676
    • /
    • 2018
  • Most reservoirs in Korea have a low water depth and are small in size. Water pollution of the reservoir is serious because of the organic matter flowing from livestock wastewater, domestic sewage, and farmland. In this study, an attempt was made to improve the water purification effect by replacing the secondary dam installed in the depression area of the agricultural reservoir with the riprap dam. To evaluate the long-term performance, a riprap dam was installed in a reservoir in Gyeonggi province and water purification effect for 36 months was measured. The field test results showed that COD was 14.6%, SS 38.6%, T-N 9.5%, and T-P 11.2%. The concentrations in the influent water exhibited a significant change according to season, and the water purification effect increased with increasing concentration of influent water. The pollutant flowing into the lake from the depression area can be blocked effectively if the secondary riprap dam for water purification is installed in the agricultural reservoir.

Secondary Productivity of Pelagic Zooplankton in lake Paldang and lake Cheongpyeong

  • Kang, Ji-Soon;Joo, Sung-Bae;Nam, Sung-Jin;Jeong, Ga-Ram;Yang, Dong-Woo;Park, Hae-Kyung;Park, Sang-Kyu
    • Journal of Ecology and Environment
    • /
    • v.32 no.4
    • /
    • pp.257-265
    • /
    • 2009
  • We estimated monthly and annual secondary productivity of pelagic zooplankton in Lake Paldang and Lake Cheongpyong. Secondary productivity was calculated by combining estimated zooplankton biomass and biomass-specific productivity for each site and depth from March to November 2008. In addition to somatic production, we measured production of eggs and exuviae for three dominant species: Daphnia galeata, Bosmina longirostris, Cyclops sp. In terms of biomass, B. longirostris was dominant in Lake Paldang in April and May, B. longirostris showed explosive biomass growth, especially in May. In June and July, B. longirostris and D. galeata were both dominant. Lake Cheongpyeong showed much lower zooplankton biomass than Lake Paldang. In August, there was little or no biomass in both lakes probably due to heavy rain. The Gyeongan River contributed most of the secondary productivity and B. longirostris contributed the most secondary productivity in Lake Paldang. D. galeata also contributed in the Gyeongan River, the South Han River and at the Paldang Dam in spring and fall. Overall, Lake Cheongpyeong showed lower secondary productivity than Lake Paldang. B. longirostris made the largest contribution to secondary productivity in the Cheongpyeong Dam area while D. galeata contributed the most near Nami Island. Somatic production constituted ~80% of the total secondary productivity (the sum of somatic, egg and exuvia production) for D. galeata and B. longirostris. Although production-to-biomass (P/B) ratios were usually <<1 B. longirostris sometimes showed very high P/B ratios, probably due to fish predation. D. galeata showed much lower P/B ratios than B. longirostris after the summer at most sites.

Thermo-structural monitoring of RCC dam in India through instrumentation

  • Ashtankar, V.B.;Chore, H.S.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.95-113
    • /
    • 2015
  • The knowledge of the behavior of any roller compacted concrete (RCC) dam and its foundation is gained by studying the service action of the dam and its foundation using measurements of an external and internal nature. The information by which a continuing assurance of structural safety of the RCC dam can be gauged is of primary importance. Similarly, the fact that the information on structural and thermal behavior and the properties of concrete that may be used to give added criteria for use in the design of future RCC dams is of secondary importance. Wide spread attention is now being given to the installation of more expensive instrumentation for studying the behavior of concrete dams and reservoirs and forecasting of any adverse trends. In view of this, the paper traces installation and need of the comprehensive instrumentation scheme implemented to monitor the structural and thermal behavior of 102.4 m high RCC dam constructed near Mumbai in India. An attempt is made in the present paper to emphasize the need to undertake an instrumentation program and evaluate their performance during construction and post construction stage of RCC structures. Few typical results, regarding the thermal and structural behavior of the dam, obtained through instrumentation installed at the dam site are presented and compared with the design considerations. The fair agreement is seen in the response observed through instrumentation with that governing the design criteria.

Syntaxonomy and Synecology of Quercus variabilis Forest in Daecheong-dam basin (대청댐 유역 굴참나무림의 군락분류학 및 군락생태학적 연구)

  • Kim, Sung-Yeol;Moon, Geon-Soo;Song, Won-Kyong;Choi, Jaeyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.15-34
    • /
    • 2021
  • Syntaxonomy and Synecology on Quercus variabilis forests in Daecheong-dam basin was carried out using the methods of Braun-Blanquet phytosociology. 6 syntaxa classified as species compositions described were Quercus variabilis community, Platycarya strobilacea-Quercus variabilis community(typicum subcommunity, dictamnus dasycarpus subcommunity), Quercetum variabili-serratae, Zelkova serrata-Quercus variabilis community and Dendranthema boreale-Quercus variabilis community. All syntaxa were shown habitat environmental conditions including steep inclination of more than 30°, high rock exposure rate of more than 50% and South-facing slope. These communities excepting Dendranthema boreale-Quercus variabilis community classified as natural vegetation were identified as low emergence rate of annual plants and species compositions composed native species, so it was confirmed that relatively natural succession were proceeding well. Quercetum variabili-serratae and Dendranthema boreale-Quercus variabilis community distributed forested hillslope of open water edge were representative Quercus variabilis syntaxa in Daecheong-dam basin.

Phytosociological Characteristics of Qeurcus acutissima Forest in Daecheong-dam basin (대청댐 유역 상수리나무림의 식물사회학적 특성)

  • Kim, Sung-Yeol;Moon, Geon-Soo;Lim, Sung-Been;Paek, Hye-Jung;Song, Won-Kyong;Choi, Jae-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.2
    • /
    • pp.85-102
    • /
    • 2021
  • Phytosociological characteristics on Quercus acutissima forests distribution in Daechong-dam basin survey has been carried out using Z.-M. School's methodology and numerical-classification analyses. A total of 43 phytosociological relevés were sampled. Syntaxa were described as Oplismenus undulatifolius-Quercus acutissima community(typicum subcommunity, Phryma leptostachya var. asiatica subcommunity, Ulmus davidiana var. japonica subcommunity), Quercus acutissima community and Quercus variabilis-Quercus acutissima community (typicum subcommunity, Castanea crenata subcommunity). The above three plant communities were classified with species composition reflecting local environmental characteristics of mountain topographies, inclination degrees, and rock exposure rates. Conclusively, those communities were recognized as secondary vegetation affected by high intensity and frequency of human impacts as they inhabited in southward hill lands and low lying grounds in mountains adjacent to human settlements and arable lands. Quercus acutissima community was classified as rural type syntax based on their inlandward distribution and species composition differences from urban forests. Afforest process and natural succession were discussed in relation with habitat environmental elements of Quercus acutissima forest in the survey area.

Therapeutic Outcome and Recurrence Rate of Helicobacter pylori Infection in Children (소아에서 Helicobacter pylori 감염에 대한 치료결과 및 재발률)

  • Choi, Won-Jun;Kim, Je-Woo;Chung, Ki-Sup
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.37-44
    • /
    • 1998
  • Purpose: This study aimed at evaluating the therapeutic outcome, cost effectiveness and recurrence rate in children with H. pylori infection after the treatment using various medications. Methods: Seventy five children (mean age $11.4{\pm}2.5$ years) were given an endoscopy with biopsy and H. pylori status assessed by CLO test and histologic examination (Warthin Starry stain). Children were given one of following medications such as DA ($Denol^{(R)}$ and amoxycillin), OA (omeprazole and amoxycillin), DC ($Denol^{(R)}$ and clarithromycin) as primary treatment. And one of following medications such as DAM ($Denol^{(R)}$, amoxycillin and metronidazole), DC, OA, OC (omeprazole and clarithromycin) were used in children who failed the eradication of H. pylori. Results: The endoscopic diagnoses were: nodular gastritis (46 cases), gastric ulcer (9), duodenal ulcer (6), superficial gastritis (6), and normal (8). H. pylori eradication rate was 91% (63 of 69 children) on 4 weeks course of DA, 50% (1 of 2 cases who had treatment failure on DA) on DAM, and 75% (3 of 4 cases who treated on DC primarily) and 50% (1 of 2 cases who had treatment failure on DA) on DC, and 100% on OA (all of 2) and on OC (all of 1 who failed on DA). In 3 of 7 children in whom H. pylori had not been eradicated by primary medications (DA 6 and DC 1 case), H. pylori was re-eradicated by secondary medications (DA 1, DAM 1 and DC 1 case). But in remaining 4 cases, H. pylori infection persisted. Reinfection of H. pylori was found in 4 of 75 children between 3 months and 3 years after completion of the treatment of DA, yielding recurrence rate of 5.3%. In 2 of 4 cases who had relapsed, H. pylori was re-eradicated by secondary medications (OC 1 and DA 1 case). But in remaining 2 cases, H. pylori infection persisted. Conclusion: These results suggest that dual therapy with $Denol^{(R)}$ and amoxycillin is the effective medications in treating H. pylori infection in children. Concerning the cost effectiveness, it can be recommended as first line treatment of choice as well.

  • PDF

An Empirical Study on The Relationships of Service Quality, Customer Satisfaction and Its Influencing Variables in Medical Service area (의료서비스의 품질 및 고객만족 관련 변수들의 관계에 관한 실증적 연구)

  • Cho, Hyun-Joo
    • Korea Journal of Hospital Management
    • /
    • v.4 no.1
    • /
    • pp.171-189
    • /
    • 1999
  • This study aims to investigate the determinants of service quality and the relationships of service quality, customer satisfaction, word of mouth and subsequent purchase intention of medical service. SERVQUAL, an instrument developed by the marketing area, is offered as a possible measure of medical service quality. SERVQUAL measures service dimension of tangibles, reliability, responsiveness, assurance and empathy. The questionnaire method is used in this study. A survey is conducted on patients who are randomly selected. The questionnaire are sent to 300 patients and 208 are available. The objectives of this study were: 1) to find out the influence of determinants of service quality on medical service. 2) to investigate the relationship of medical service quality and customer satisfaction. 3) to analyze the relationship of customer satisfaction and favorable word of mouth, ubsequent purchase intention 4) to find out the gap perceived service quality between secondary and tertiary hospital. The results of this study are summarized as follows: 1) Reliability, responsiveness and assurance have a positive impact on the medical service quality. 2) Medical service quality has a positive impact on the customer satisfaction. 3) Customer satisfaction has a positive impact on the favorable word of mouth and subsequent purchase intention. 4) There is no gap between secondary and tertiary hospital of perceived service quality.

  • PDF

Geochemical Approach to Define the Fracture Bone Affected by the Ubo Fault at the Northern Part of the Hwabuk Dam (화북댐 상류지역을 통과하는 우보단층 파쇄대 영향분석을 위한 지화학적 접근)

  • Kwon Yong Wan
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.191-200
    • /
    • 2004
  • The Ubo fault Bone, which cross over the northwestern to southeastern direction at the Hwabuk damsite in Hakseongri, Gunwigun, Gyeongsangbukdo Province, has length about 20km. The Ubo fault zone in this area is segmented to several small faults and makes a gentle slope and hill along the right side of the drainage in the Hwabuk dam. In the storage area of Hwabuk dam, 2 pairs of faults occur and the width of fracture zones are about 2m. To define the fracture Bone using the geochemical data, the samples were collected at 0.5m, 1m, 2m, 4m, 8m, 16m and 32m apart from the center of the main fracture Bone toward north and south, respectively, and analyzed for major elements and mineral content Approaching the fracture Bone, Fe$_2$O$_3$, MgO, K$_2$O, quartz, muscovite and chlorite are increasing and Na$_2$O, CaO, plagioclase and biotite are decreasing, respectively. Based on the rock chemistry and mineral content, the range of the main fracture zone affected by the Ubo fault at Hakseongri is 2m width in total, the secondary deformed zone is 8m width in total. Finally the maximum affected range by the Ubo fault is inferred to 16m width in total.

Study on the Effective Stiffness of Base Isolation System for Reducing Acceleration and Displacement Responses

  • Kim, Young-Sang
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.586-594
    • /
    • 1999
  • To limit both the large displacement and acceleration response of the structure efficiently, the relationships between acceleration and displacement responses of the structure under several earthquakes are investigated for various horizontal stiffness of the base isolation system to determine the effective stiffness of the base isolation system in this paper. An example structure is a five-storey steel frame building as the primary structure and the secondary structures are assumed to be located on the fifth floor of the primary structure. Input motions used in the structural analysis are El Centre 1940, Taft 1952, Mexico 1985, San Fernando 1971 Pacoima Dam, and artificially generated earthquakes. The relationships of the absolute peak acceleration and the displacement at the top of the structure are calculated for various natural periods of base isolators under various earthquakes. The peak acceleration response of the fifth floor in the base isolated structure is significantly reduced by a factor of 2.1 through 6.25. Also, the relative displacement response of the floor to the base of the superstructure is very small. The results of this study can be utilized to determine the effective stiffness of the base isolation system.

  • PDF

An Optimal Operation of Multi-Reservoirs for Flood Control by Incremental DP (Incremental DP에 의한 홍수시 댐군의 연계운영)

  • Lee, Jae-Hyeong;Lee, Gil-Seong;Jeong, Dong-Guk
    • Water for future
    • /
    • v.25 no.2
    • /
    • pp.47-60
    • /
    • 1992
  • An optimal operation model for flood control of multi-reservoirs, Hwacheon and Soyanggang, located in the north Han River basin is developed by using the Incremental DP. The objective function is to minimize the peak flow at the confluence point, of Euam dam, and the hydraulic and hydrologic constraints are established by considering the related laws as to the operation of dam in flood season, each reservoir and channel characteristics. In particular, the final elevations of each reservoir are induced to the conservation pool level in order to prepare for the secondary flood. In addition, the results of this model, simulation results and the single reservoir operation by DP are compared in terms of control and utility efficiencies, and also the peak flows at the confluence point for floods with various return periods are compared with the results of simulation suing feedback control. as the results, the control and utility effciencies are more or less low in contrast with the results of simulation and the single reservoir operation by DP, and the peak flows at confluence point are high because of terminal condition of reservoir storage.

  • PDF