• Title/Summary/Keyword: Secondary Reaction Plate

Search Result 26, Processing Time 0.03 seconds

The Analysis of Transverse Edge Effect of Linear Induction Motor by using Finite Element Method (유한요소법을 이용한 선형유도전동기의 횡방향 모서리 효과 분석)

  • Lee, Sung-Gu;Bae, Jae-Nam;Lee, Hyung-Woo;Park, Hyun-June;Kwon, Sam-Young;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2194-2198
    • /
    • 2008
  • In this paper, the construction of secondary reaction plate is analyzed by 3-D Finite Element Method(3-D FEM) to consider the influence of its variation on the transverse edge effect of LIM. The effective 3-D analysis model for considering the transverse edge effect caused by the finite widths of the primary and the secondary is proposed. The simple method measuring the transverse edge effect by using the patterns of currents induced in the secondary reaction plate is also proposed. With this effective analysis method, various models of secondary reaction plate with overhang and cap has been analyzed to consider the relationship between the construction of secondary reaction plate and the transverse edge effect of LIM.

A Study on the Thrust Characteristic Analysis of Linear Induction Motor according to Secondary Reaction Plate Using the Container Scanner Vehicle (컨테이너 검색기 이송대차 추진용 선형 유도전동기의 2차측 리액션플레이트 재질에 따른 특성 연구)

  • Jeong, Jae-Hoon;Choi, Jang-Young;Sung, So-Young;Park, Jong-Won;Lim, Jaewon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.65-72
    • /
    • 2016
  • This paper presents the analysis of the analysis of thrust characteristics of linear induction motors(LIMs) according to secondary reaction plate. LIMs are well known as high speed transport systems, which can obtain thrust directly without gears and links, or auxiliary mechanisms. A simple structure, easy maintenance, and less environmental pollution are advantages of LIMs. In transport systems using LIMs, the secondary reaction plate is an important design factor, because it has considerable impact on the cost of the railway as well as the performance of the LIMs. This paper deals analyzed the characteristics of linear induction motor used for moving the vehicle of container scanner. Thrust, efficiency and load characteristic were interpreted with FEM regarding two models whose material of secondary reaction plate was copper and aluminum. It suggested the interpretation of thrust, efficiency and power factor characteristic along slip and compared the operation ability of linear induction motor through characteristics analysis along the load.

A Study on the Thrust Characteristic Analysis of Linear Induction Motor according to Secondary Reaction Plate (선형 유도전동기의 2차측 리액션 플레이트에 따른 추력특성 연구)

  • Jeong, Jae-Hoon;Choi, Jang-Young;Lim, Jaewon;Sung, So-Young
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.730-731
    • /
    • 2015
  • This paper presents the analysis of the analysis of thrust characteristics of linear induction motors(LIMs) according to secondary reaction plate. LIMs are well known as high speed transport systems, which can obtain thrust directly without gears and links, or auxiliary mechanisms. A simple structure, easy maintenance, and less environmental pollution are advantages of LIMs. In transport systems using LIMs, the secondary reaction plate is an important design factor, because it has considerable impact on the cost of the railway as well as the performance of the LIMs.

  • PDF

LIM 2차측 도체형상의 알루미늄 사용량과 추진특성과의 관계

  • Park, Hyun-June;Lee, Hyung-Woo;Kim, Hyung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.251-251
    • /
    • 2010
  • Linear induction motor performance for a light-weight urban transit has been established and verified. In this paper, linear induction motor is analyzed by finite-element method to consider influence of construction of secondary reaction plate on the transverse edge effect. With this effective analysis method, various models with overhang and cap have been analyzed to consider the relationship between the construction of secondary reaction plate and the transverse edge effect.

  • PDF

Characteristic Analysis of a Linear Induction Motor for a Lightweight Train According to Various Secondary Schemes

  • Lee, Hyung-Woo;Lee, Sung-Gu;Park, Chan-Bae;Lee, Ju;Park, Hyun-June
    • International Journal of Railway
    • /
    • v.1 no.1
    • /
    • pp.6-11
    • /
    • 2008
  • This paper presents a performance characteristic analysis methodology for a linear induction motor used for a lightweight train. In general, an analytical method cannot provide accurate results in a linear motor because of large airgap, end effect, transverse edge effect, 3-dimensional configurations, large leakage, and so on. Besides, a numerical method requires lots of memory and solving time for transient analysis. However, the suggested methodology which is a kind of hybrid solution with an analytical method and a numerical method is very fast and accurate. Based on the methodology, 3-D FEM analyses for various design schemes of the secondary reaction plate have been done and from the analysis results, the best configuration for an urban railway transit is chosen.

  • PDF

Influence of the airgap tolerance on performance of a Linear Induction Motor (공극 공차가 선형유도전동기에 미치는 영향)

  • Lee, H.W.;Lee, S.G.;Park, C.;Kwon, S.Y.;Lee, B.S.;Lee, Ju;Park, H.J.
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1468-1472
    • /
    • 2009
  • This paper presents the influence of the airgap tolerance on performance of a linear induction motor. Construction tolerance of the plate affects directly to the cost and performance of the Linear metro. LIM has around 10[mm] large airgap with many restrictions such as construction tolerance, thermal expansion and bend of the reaction plate, abrasion of the wheel, and so on. In order to have steady performance, the airgap should be uniform. But it is impossible to maintain the secondary reaction plate be flat along with the long track. Therefore the influence of the flatness on performance of a LIM should be investigated.

  • PDF

SORET, HALL CURRENT, ROTATION, CHEMICAL REACTION AND THERMAL RADIATION EFFECTS ON UNSTEADY MHD HEAT AND MASS TRANSFER NATURAL CONVECTION FLOW PAST AN ACCELERATED VERTICAL PLATE

  • VENKATESWARLU, M.;LAKSHMI, D. VENKATA;RAO, K. NAGA MALLESWARA
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.20 no.3
    • /
    • pp.203-224
    • /
    • 2016
  • The heat and mass transfer characteristics of the unsteady hydromagnetic natural convection flow with Hall current and Soret effect of an incompressible, viscous, electrically conducting, heat absorbing and optically thin radiating fluid flow past a suddenly started vertical infinite plate through fluid saturated porous medium in a rotating environment are taken into account in this paper. Derivations of exact analytical solutions are aimed under different physical properties. The velocity, concentration and temperature profiles, Sherwood number and Nusselt number are easily examined and discussed via the closed forms obtained. Soret effect and permeability parameter tends to accelerate primary and secondary fluid velocities whereas hall current, radiation and heat absorption have reverse effect on it. Radiation and heat absorption have tendency to enhance rate of heat transfer at the plate. The results obtained here may be further used to verify the validity of obtained numerical solutions for more complicated transient free convection fluid flow problems.

CLINICAL AND RADIOLOGICAL COMPARISON BETWEEN TITANIUM AND BIODEGRADABLE MINIPLATE MONOCORTICAL OSTEOSYNTHESIS IN MANDIBULAR ANGLE FRACTURES (Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구)

  • Choi, Eun-Joo;Nam, Woong;Jung, Young-Soo;Kim, Ki-Ho;Kim, Hyung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.222-225
    • /
    • 2006
  • The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.

Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

  • Jeon, Hong Bae;Kang, Dong Hee;Gu, Ja Hea;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.40-45
    • /
    • 2016
  • Background Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws. Methods A total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland) plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA) in 61 patients. Their mean age was 35.2 years (range, 15-84 years). Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla. Results Complications occurred in eight (3.4%) of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction. Conclusions Inadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.