References
- Bergsma JE, de Bruijn WC, Rozema FR, et al. Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials 1995;16:25-31. https://doi.org/10.1016/0142-9612(95)91092-D
- Rubin JP, Yaremchuk MJ. Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature. Plast Reconstr Surg 1997;100:1336-53. https://doi.org/10.1097/00006534-199710000-00043
- Orringer JS, Barcelona V, Buchman SR. Reasons for removal of rigid internal fixation devices in craniofacial surgery. J Craniofac Surg 1998;9:40-4. https://doi.org/10.1097/00001665-199801000-00009
- Wiltfang J, Merten HA, Schultze-Mosgau S, et al. Biodegradable miniplates (LactoSorb): long-term results in infant minipigs and clinical results. J Craniofac Surg 2000;11:239-43. https://doi.org/10.1097/00001665-200011030-00006
- Imola MJ, Hamlar DD, Shao W, et al. Resorbable plate fixation in pediatric craniofacial surgery: long-term outcome. Arch Facial Plast Surg 2001;3:79-90. https://doi.org/10.1001/archfaci.3.2.79
- Mackool R, Yim J, McCarthy JG. Delayed degradation in a resorbable plating system. J Craniofac Surg 2006;17:194-7. https://doi.org/10.1097/01.scs.0000194167.50546.7e
- Katsuragi YT, Gomi A, Sunaga A, et al. Intracerebral foreign body granuloma caused by a resorbable plate with passive intraosseous translocation after cranioplasty. J Neurosurg Pediatr 2013;12:622-5. https://doi.org/10.3171/2013.9.PEDS13187
- Xue AS, Koshy JC, Weathers WM, et al. Local foreign-body reaction to commercial biodegradable implants: an in vivo animal study. Craniomaxillofac Trauma Reconstr 2014;7:27-34. https://doi.org/10.1055/s-0033-1364199
- Bell RB, Kindsfater CS. The use of biodegradable plates and screws to stabilize facial fractures. J Oral Maxillofac Surg 2006;64:31-9.
- Pietrzak WS, Sarver DR, Verstynen ML. Bioabsorbable polymer science for the practicing surgeon. J Craniofac Surg 1997;8:87-91. https://doi.org/10.1097/00001665-199703000-00004
- Eppley BL, Morales L, Wood R, et al. Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients. Plast Reconstr Surg 2004;114:850-6. https://doi.org/10.1097/01.PRS.0000132856.69391.43
- Kwon H, Kim SW, Jung SN, et al. Cellulitis related to bioabsorbable plate and screws in infraorbital rim fracture. J Craniofac Surg 2011;22:625-7. https://doi.org/10.1097/SCS.0b013e3182085541
- Kumar AV, Staffenberg DA, Petronio JA, et al. Bioabsorbable plates and screws in pediatric craniofacial surgery: a review of 22 cases. J Craniofac Surg 1997;8:97-9. https://doi.org/10.1097/00001665-199703000-00006
- Bergsma EJ, Rozema FR, Bos RR, et al. Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral Maxillofac Surg 1993;51:666-70. https://doi.org/10.1016/S0278-2391(10)80267-8
- Miller RA, Brady JM, Cutright DE. Degradation rates of oral resorbable implants (polylactates and polyglycolates): rate modification with changes in PLA/PGA copolymer ratios. J Biomed Mater Res 1977;11:711-9. https://doi.org/10.1002/jbm.820110507
- Laughlin RM, Block MS, Wilk R, et al. Resorbable plates for the fixation of mandibular fractures: a prospective study. J Oral Maxillofac Surg 2007;65:89-96.
- Rha EY, Paik H, Byeon JH. Bioabsorbable plates and screws fixation in mandible fractures: clinical retrospective research during a 10-year period. Ann Plast Surg 2015;74:432-6. https://doi.org/10.1097/SAP.0b013e3182a60693
- Sevastjanova NA, Mansurova LA, Dombrovska LE, et al. Biochemical characterization of connective tissue reaction to synthetic polymer implants. Biomaterials 1987;8:242-7. https://doi.org/10.1016/0142-9612(87)90110-4
Cited by
- Inflammatory foreign body reaction caused by resorbable materials used for orbital fractures repair : A case report vol.96, pp.49, 2016, https://doi.org/10.1097/md.0000000000008822
- Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial vol.12, pp.5, 2017, https://doi.org/10.1371/journal.pone.0177152
- Aesthetic treatment of frontal sinus fractures and their complications vol.61, pp.12, 2016, https://doi.org/10.5124/jkma.2018.61.12.732
- Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates vol.19, pp.2, 2016, https://doi.org/10.7181/acfs.2018.00038
- Surface‐modified halloysite nanotubes reinforced poly(lactic acid) for use in biodegradable coronary stents vol.135, pp.30, 2016, https://doi.org/10.1002/app.46521
- Design of biodegradable, implantable devices towards clinical translation vol.5, pp.1, 2020, https://doi.org/10.1038/s41578-019-0150-z
- A Novel Screw Drive for Allogenic Headless Position Screws for Use in Osteosynthesis-A Finite-Element Analysis vol.8, pp.10, 2021, https://doi.org/10.3390/bioengineering8100136
- Safety and feasibility assessment of biodegradable poly (L-lactic acid/ε-caprolactone) membrane for guided bone regeneration: A case series of first-in-human pilot study vol.17, pp.1, 2016, https://doi.org/10.1016/j.jds.2021.08.015