• 제목/요약/키워드: Secondary Air System

검색결과 272건 처리시간 0.03초

유비쿼터스 환경에능동형 창고 상태관리를 위한 보안 프로토콜 설계 (A Design of Security Protocol for Active Warehouse Condition Management System based on Ubiquitous Environment)

  • 전영준;최용식;신승호;박상민
    • 대한안전경영과학회지
    • /
    • 제8권6호
    • /
    • pp.91-108
    • /
    • 2006
  • RFID/USN is important infrastructure of the ubiquitous society. And so, It is various and practical research is attempted. These two base technology have physical characteristic and complement relationship. Like this relationship is applied Following example that is system research which manages warehouse stocks and conditions. First, We adhere RFID Tag at the Pallet of the warehouse and do identification goods. And then, It grasps the environment state information of stocks with sensor module which has Zigbee wireless communication function. From like this process RFID Tag information and jop-control command of sensor node also it is exposed to air. Therefore, We control sensor node in USN/RFID environment through the mobile device. And system design for the security Apply of the process is main purpose of this paper's. We propose the condition and function of the mobile device to the secondary. And We define the relation of the sensor node with RFID to be arranged to a warehouse. Finally, This paper is designed to find a trade-off of the following viewpoints. First, We offer suitable sensor-control information to a actual manager. Second, We offer RFID tag security approach to control the action of the sensor. Third, It increases the survivability of sensor node form.

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.

반복하중을 받는 경량 배관 서포트 시스템에 대한 실험적 성능 평가 (Experimental Capacity of Suspended Piping Trapeze Restraint Installations under Cyclic Loadings)

  • 정상덕;오창수;박민재;이창환
    • 한국공간구조학회논문집
    • /
    • 제23권3호
    • /
    • pp.79-86
    • /
    • 2023
  • Damage to gas and fire protection piping systems can lead to secondary disasters after an earthquake, so their seismic design is crucial. Accordingly, various types of seismic restraint installations are being devised, and a new suspended piping trapeze restraint installation has also recently been developed in Korea. In this study, a cyclic loading test was performed on the developed trapeze support system, and its performance was evaluated according to ASHRAE 171, the standard for seismic and wind restraint design established by the American Society of Refrigeration and Air Conditioning Engineers (ASHRAE). The three support system specimens did not break or fracture, causing only insignificant deformations until the end of the experiment. Based on the experimentally rated strength and displacement performance, this trapeze support system is expected to control the seismic movement of piping during an earthquake.

공기 중에서 망간 다이옥사이드에 의한 아민에서 이민 또는 나이트릴로의 선택적 산화 반응 (Selective Oxidation of Amines to Imines or Nitriles by Manganese Dioxide in Air)

  • 김요한;황승규;이윤식;김정원
    • 공업화학
    • /
    • 제25권2호
    • /
    • pp.215-221
    • /
    • 2014
  • 염기 처리에 의한 간단한 방법으로 합성된 $MnO_2$ (B-$MnO_2$)는 불균일 촉매시스템으로 호기성 조건에서 효과적인 아민 산화반응을 보여주었다. 이 B-$MnO_2$ 촉매는 다양한 종류의 방향족, 이원자 화합물, 비활성 지방족 등의 아민의 전환에 높은 활성과 선택성을 보여주었다. 이러한 산화반응은 온화한 온도($50^{\circ}C$)와 대기압의 공기 조건하에서 아민을 중간체인 이민으로 전환하고 자가 축합(self-condensation) 또는 산화적 탈수소화(oxidative dehydrogenation)을 통해 다이이민(diimine) 또는 나이트릴(nitrile)을 생성하였다. 사용된 촉매는 여과로 쉽게 분리할 수 있었고 5번 이상의 재사용 실험에서도 일정이상의 높은 수율을 보여주었다. 따라서 B-$MnO_2$는 아민 산화반응을 통해 이민과 나이트릴을 얻음에 있어 경제적으로나 환경친환적으로 효과적인 면을 보여 줌으로써, 그린화학(green chemistry)의 목적에 적합하다.

Enhanced Piezoelectric Properties of (1-x)[0.675BiFeO3-0.325BaTiO3]-xLiTaO3 Ternary System by Air-Quenching

  • Akram, Fazli;Malik, Rizwan Ahmed;Lee, Soonil;Pasha, Riffat Asim;Kim, Myong Ho
    • 한국재료학회지
    • /
    • 제28권9호
    • /
    • pp.489-494
    • /
    • 2018
  • Lead free $(1-x)(0.675BiFeO_3-0.325BaTiO_3)-xLiTaO_3$ (BFBTLT, x = 0, 0.01, 0.02, and 0.03, with 0.6 mol% $MnO_2$ and 0.4 mol% CuO) were prepared by a solid state reaction method, followed by air quenching and their crystalline phase, morphology, dielectric, ferroelectric and piezoelectric properties were explored. An X-ray diffraction study indicates that lithium (Li) and tantalum (Ta) were fully incorporated in the BFBT materials with the absence of any secondary phases. Dense ceramic samples (> 92 %) with a wide range of grain sizes from $3.70{\mu}m$ to $1.82{\mu}m$ were obtained in the selected compositions ($0{\leq}x{\leq}0.03$) of BFBTLT system. The maximum temperatures ($T_{max}$) were mostly higher than $420^{\circ}C$ in the studied composition range. The maximum values of maximum polarization ($P_{max}{\approx}31.01{\mu}C/cm^2$), remnant polarization ($P_{rem}{\approx}22.82{\mu}C/cm^2$) and static piezoelectric constant ($d_{33}{\approx}145pC/N$) were obtained at BFBT-0.01LT composition with 0.6 mol% $MnO_2$ and 0.4 mol% CuO. This study demonstrates that the high $T_{max}$ and $d_{33}$ for BFBTLT ceramics are favorable for industrial applications.

Component Analysis of Thermally Activated Building System in Residential Buildings

  • Chung, Woong June;Lee, Yu Ji;Yoo, Mi Hye;Park, Sang Hoon;Yeo, Myoung Souk;Kim, Kwang Woo
    • Architectural research
    • /
    • 제16권4호
    • /
    • pp.203-210
    • /
    • 2014
  • The packaged terminal air conditioner, the typical cooling system for the residential buildings, consumes a large amount of electricity in a short period time during peak hours. In order to reduce the peak load and conserve the electricity, the thermally activated building system can be used as a secondary system to handle the partial cooling load. However, the thermally activated building system may cause condensation and under-cooling. Thus, design of both systems should be performed with careful investigation in characteristics of both systems to amplify the advantages. Since the thermally activated building system has the time-delay effect which may cause under-cooling, the system is designed to handle the base load of the building. Hence, simple simulation with EnergyPlus was performed to observe the characteristics of cooling load in residential buildings. Once the possible range of the load handling ratio of the thermally activated building system was decided, characteristics of system was analyzed in terms of hardware component and operation parameters. The hardware components were analyzed in plant and system aspects and the operation parameter was evaluated in the thermal comfort aspect. As the load handling ratio increased, the thermal comfort increased due to the lower radiant mean temperatures. Within the range of thermal comfort, the several adjustments were made in setpoint temperature and electricity consumptions of difference cases were observed to decide which components and parameters were important for designing the systems.

곡관덕트에서 난류진동유동의 전단응력분포와 압력분포 (Wall shear stress and Pressure Distributions of Developing Turbulent Oscillatory Flows in a Square sectional Curved Duct)

  • 이홍구;손현철;이행남;박길문
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.380-385
    • /
    • 2001
  • In the present study, flow characteristics of turbulent oscillatory flow in a square-sectional $180^{\circ}$ curved duct are investigated experimentally. In order to measure wall shear stress and pressure distributions, experimental studies for air flow are conducted in a square-sectional $180^{\circ}$ curved duct by using the LDV system with the data acquisition and the processing system. The wall shear stress measuring point bend angle of the $150^{\circ}$ and pressure distribution of the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) at $10^{\circ}$ intervals of the duct. The results obtained from the experimentation are summarized as follows: A wall shear stress value in an inner wall is larger than that in an outer wall, except for the phase angle (${\omega}t/{\pi}/6$) of 3, because of the intensity of secondary flow. The pressure distributions are the largest in accelerating and decelerating regions at the bend angle(${\phi}$) of $90^{\circ}$ and pressure difference of inner and outer walls is the largest before and after the ${\phi}=90^{\circ}$.

  • PDF

가진 펌프에 연결된 곡관덕트에서 난류진동유동의 전단응력분포와 압력분포 (Wall Shear Stress and Pressure Distributions of Developing Turbulent Oscillatory Flows in an Oscillator Connected to Curved Duct)

  • 손현철;이홍구;이행남;박길문
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.37-42
    • /
    • 2001
  • In the present study, flow characteristics of turbulent oscillatory flow in an oscillator connected to square-sectional $180^{\circ}$ curved duct are investigated experimentally. In order to investigate wall shear stress and pressure distributions, the experimental studies for air flows we conducted in a square-sectional $180^{\circ}$ curved duct by using the LDV system with the data acquisitions and the processing system. The wall shear stress at bend angle of the $150^{\circ}$ and pressure distribution of the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) by $10^{\circ}$ intervals of the duct are measured. The results obtained from the experiment are summarized as follows : wall shear stress values in the inner wall we larger than those in an outer wall, except for the phase angle (${\omega}t/{\pi}/6$) of 3, because of the intensity of secondary flow. The pressure distributions are the largest in accelerating and decelerating regions at the bend angle(${\phi}$) of $90^{\circ}$ and pressure difference of inner and outer walls is the largest before and after the ${\phi}=90^{\circ}$.

  • PDF

분진-미스트 시스템을 이용한 실시간 수용성 유기탄소 분석 (Time Resolved Analysis of Water Soluble Organic Carbon by Aerosol-into-Mist System)

  • 조인환;박다정;배민석
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.497-507
    • /
    • 2015
  • Real-time and quantitative measurement of the chemical composition in ambient aerosols represents one of the most challenging problems in the field of atmospheric chemistry. In the present study, time resolved application by Aerosol-into-Mist System (AIMS) following by total organic carbon analyzer (TOC) has been developed. The unique aspect of the combination of these two techniques is to provide quantifiable water soluble organic carbon (WSOC) information of particle-phase organic compounds on timescales of minutes. We also demonstrated that the application of the AIMS method is not limited to water-soluble organic carbon but inorganic ion compounds. By correlating the volume concentrations by optical particle sizer (OPS), water soluble organic carbon can be highly related to the secondary organic products. AIMS-TOC method can be potentially applied to probe the formation and evolution mechanism of a variety of SOA behaviors in ambient air.

200kW급 마이크로 가스터빈 시스템의 설계 변수 민감도 해석 (Design Parameter Sensitivity Analysis of a 200kW Class Micro Gas Turbine System)

  • 신현동;강도원;김동섭;최문경;박필제
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.39-45
    • /
    • 2012
  • This paper describes the outcome of the design of a 200 kW class micro gas turbine and the sensitivity of its performance (efficiency and power) to the variations in major design parameters. The reference design parameters were set up based on the best available component technologies. The resulting net electricity generation efficiency of the micro gas turbine package was found to be competitive to those of other systems in the market. The sensitivities of power and efficiency to the variations in compressor and turbine efficiencies, pressure ratio, turbine inlet temperature, recuperator effectiveness, secondary air ratio, pressure loss ratios of both the cold and hot sides of the recuperator were estimated. Based on the sensitivity data, a simplified method to predict the variation in system performance responding to the combinations of small changes in all design parameters were set up and validated.