Design Parameter Sensitivity Analysis of a 200kW Class Micro Gas Turbine System

200kW급 마이크로 가스터빈 시스템의 설계 변수 민감도 해석

  • Received : 2012.05.11
  • Accepted : 2012.09.19
  • Published : 2012.12.01

Abstract

This paper describes the outcome of the design of a 200 kW class micro gas turbine and the sensitivity of its performance (efficiency and power) to the variations in major design parameters. The reference design parameters were set up based on the best available component technologies. The resulting net electricity generation efficiency of the micro gas turbine package was found to be competitive to those of other systems in the market. The sensitivities of power and efficiency to the variations in compressor and turbine efficiencies, pressure ratio, turbine inlet temperature, recuperator effectiveness, secondary air ratio, pressure loss ratios of both the cold and hot sides of the recuperator were estimated. Based on the sensitivity data, a simplified method to predict the variation in system performance responding to the combinations of small changes in all design parameters were set up and validated.

Keywords

References

  1. Rodgers, C. and Watts, J. and Nichols, K. and Brent, R., 2001, Microturbines, in Distributed Generation, Borbely, A.M. and Kreider, J., ed., CRC Press, pp.119-150.
  2. Capstone Turbine Corporation, 2008, "Advanced Micro Turbine System(AMTS) Final Technical Report," U.S. Department Of Energy, DOE Project ID # DE-FC26- 00CH11058.
  3. 오종식, 이헌석, 2002, "분산발전용 75kW급 마이크로터빈의 시제개발-설계/제작 및 자력운전 시험-," 2002유체기계학회 연구개발 발표회 논문집, pp. 307-313.
  4. Lee, J. J., Kim, T. S., 2004, "Analysis of Operation Performance of a Micro Gas Turbine Generator System," Journal of Fluid Machinery, Vol. 8, No. 5, pp. 13-21.
  5. Lee, J. J., Yoon, J. E., and Kim, T. S.., 2006, "Operation Simulation of a Microturbine Based on Test Data", Journal of Fluid Machinery, Vol. 9, No. 6, pp. 22-28. https://doi.org/10.5293/KFMA.2006.9.6.022
  6. Lee, J. J., Yoon, J. E., Kim T. S., and Sohn, J. L., 2007, "Performance Test and Component Characteristics Evaluation of a Micro Gas Turbine," Journal of Mechanical Science and Technology, Vol. 21, No. 1, pp. 141-152. https://doi.org/10.1007/BF03161720
  7. Lee, J. J., Jeon, M. S., Kim, T. S., 2010, "The Influence of Water and Steam Injection on the Performance of a Recuperated Cycle Microturbine for Combined Heat and Power Application", Applied Energy, Vol. 87, pp. 1307-1316. https://doi.org/10.1016/j.apenergy.2009.07.012
  8. Lee, J. H., and Kim, T. S.., 2006, "Analysis of Design and Part Load Performance of Micro Gas Turbine/ Organic Rankine Cycle Combined Systems", Journal of Mechanical Science and Technology, Vol 20, pp. 1502-1513. https://doi.org/10.1007/BF02915973
  9. 박진형, 2011, "200kW급 마이크로 가스터빈 열병합발전 시스템 상용화", 2011 유체기계학회 연구개발 발표회 논문집, pp. 491-494.
  10. Enter Software, Gate Cycle ver 6.0, 2006.
  11. Bruckner, R. J., Puleo, B. J., 2008, "Compliant Foil Journal Bearing Performance at Alternate Pressures and Temperatures," ASME paper GT2008-50174.
  12. Kim, T. S., Hwang, S. H., 2006, "Part Load Performance Analysis of Recuperated Gas Turbines Considering Engine Configuration and Operation Strategy," Energy, Vol 31, pp. 260-277. https://doi.org/10.1016/j.energy.2005.01.014
  13. Kang, Y. M., and McKeirnan, R., 2003, "Annular Recuperator Development and Performance Test for 200kW Microturbine," ASME paper GT-2003-38522.

Cited by

  1. Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine vol.37, pp.11, 2013, https://doi.org/10.3795/KSME-B.2013.37.11.1015
  2. Performance Evaluation of a Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System With Oxy-Combustion Carbon Capture vol.140, pp.4, 2017, https://doi.org/10.1115/1.4038038
  3. Performance Enhancement of a Molten Carbonate Fuel Cell/Micro Gas Turbine Hybrid System With Carbon Capture by Off-Gas Recirculation vol.141, pp.4, 2012, https://doi.org/10.1115/1.4040866