• 제목/요약/키워드: Second premolar

검색결과 349건 처리시간 0.033초

Observation of an extracted premolar 2.5 years after mineral trioxide aggregate apexification using micro-computed tomography

  • Lee, Gayeon;Chung, Chooryung;Kim, Sunil;Shin, Su-Jung
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.4.1-4.6
    • /
    • 2020
  • Although numerous studies have been conducted on apexification using mineral trioxide aggregate (MTA), direct observation of extracted human teeth after the procedure has been rarely reported. This case report describes a mandibular premolar treated 2.5 years ago and extracted recently for orthodontic treatment. The tubercle of the right mandibular premolar of a 12-year-old boy with dens evaginatus was fractured and the pulp was exposed. The tooth was diagnosed with pulp necrosis and asymptomatic periapical abscess. During the first visit, copious irrigation was performed with 2.5% sodium hypochlorite. Calcium hydroxide paste was placed as an intracanal medicament. The sinus tract had disappeared at the second visit after 3 weeks. MTA was applied on to the bleeding point as a 4-mm-thick layer, followed by a 3-mm-thick gutta-percha filling and resin core build-up. After 2.5 years, the tooth and three other premolars were extracted for orthodontic treatment. The right and left mandibular premolars were scanned with micro-computed tomography to determine the root shape and canal anatomy. Irregular root growth was observed and the root outline of the right mandibular premolar differed from that of the contralateral tooth. Apexification with MTA leads to the formation of roots with irregular morphology, without any pulpal space.

개에서 골판을 이용한 비개방성 양측성 하악골절의 수복 (Repair of Closed Bilateral Mandibular Fractures Using Bone Plate and Screw in Dogs)

  • 정순욱;한현정;김지선;김준영;정만복
    • 한국임상수의학회지
    • /
    • 제20권1호
    • /
    • pp.138-141
    • /
    • 2003
  • First case, a one-year-old female Shih Tzu weighing 3 kg with closed transverse fractures of bilateral mandibular body between 2nd and 3rd premolar teeth were treated surgically with bone plates and screws, and cranial luxation of temporomandibular joints were reduced to closed method. Second case, a 8.4 years old male Yorkshire terrier weighing 2.6 kg with closed transverse/oblique fractures of bilateral mandibular body between premolar and molar teeth were treated surgically with bone plates and screws. Radiographic examination revealed that the fractures in two cases fixed well and temporomandibular joint was stabilized. One month after operation, jaw activity was excellent and malocclusion wasn't observed.

III급 부정교합의 수술-교정 치료시 상악 소구치 발치가 치열궁 폭경 변화에 미치는 영향 (Effect of maxillary premolar extraction on transverse arch dimension in Class III surgical-orthodontic treatment)

  • 이신재;홍성준;김영호;백승학;서정훈
    • 대한치과교정학회지
    • /
    • 제35권1호
    • /
    • pp.23-34
    • /
    • 2005
  • 본 연구에서는 III급 수술-교정 치료 방법에 영향을 미치는 치열 상의 요소를 파악함으로써 술전 교정시 상악 소구치 발치와 비발치의 판단에 필요한 임상적 정보를 얻고자 골격성 III급 부정교합 환자의 수술-교정 치료시 흔히 선택되는 상악 제1소구치 발치로 치료된 군과 비발치로 치료된 군 간의 치료전/후 상/하악 개별 치아 이동 양상과 치열궁 폭경의 변화 양상을 비교 분석하였다 이를 위하여 비발치로 III급 수술-교정 치료를 마친 환자 (24명) 와 술전교정 치료시 상악 제1소구치가 발치된 환자 (31 명)의 치료 전/후 모형 상에서 개개 치아의 근원심/협설측 각도 변화와 상/하 치열궁 폭경의 변화를 측정한 후, 두 군 사이의 교정적 치아 이동 양상을 비교 분석한 후 상/하 치열궁의 조화를 이루는데 필요한 치열궁 폭경의 변화와 이에 기여하는 치아 변위와의 관계를 분석하기 위하여 상관 분석과 회귀 분석을 시행한 결과 발치 군은 비발치 군에 비하여 상악 치열궁 폭경의 감소가 컸으며 이는 상악 구치의 inclination 감소에 크게 영향 받은 것으로 관찰되었다. 하악 치열에서는 inclination의 증가와 폭경의 증가가 있었으나, 비발치/발치군간의 차이는 유의하지 않았다 본 연구의 결과 결론적으로 III급 수술-교정 치료시 술전 상악 소구치 발치는 상악 구치부 치열궁 폭경의 감소에 크게 영향을 미치므로, 상악 소구치 발치에 대한 판단은 상/하악 치열궁의 폭경 및 구치부 경사도 문제와 연계하여 고려해야 할 사항으로 생각되었다.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

상악 제2유구치의 부가치근과 함께 관찰된 영구 계승치의 변위 및 회전 : 증례 보고 (Additional Root of the Primary Maxillary Second Molar Possibly Associated with Displacement and Rotation of the Permanent Successor : Two Case Reports)

  • 구재원;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제44권1호
    • /
    • pp.116-121
    • /
    • 2017
  • 상악 제2유구치의 부가치근은 드물게 관찰된다. 본 증례보고에서는 두 증례를 통해 상악 제2유구치의 부가치근과 하방 영구 계승치의 변위 및 회전이 연관되었을 가능성에 대해 논의하였다. 상악 제2유구치의 치관 형태를 관찰함으로써 부가치근의 존재 가능성을 의심할 수 있으며, 부가치근이 존재하는 경우 영구 계승치의 맹출 양상을 주의 깊게 관찰해야 할 필요가 있을 것으로 사료된다. 만약 소구치 치배가 비정상적인 맹출 양상을 보인다면 선행 유치의 조기 발거 및 공간유지가 보존적인 치료법이 될 수 있다.

Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth

  • Rosentritt, Martin;Schumann, Frederik;Krifka, Stephanie;Preis, Verena
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2020
  • PURPOSE. To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent teeth. MATERIALS AND METHODS. A mandibular left first molar (#36) with adjacent human teeth (mandibular left second premolar: #35, mandibular left second molar: #37) and antagonistic human teeth (maxillary left second premolar: #25, maxillary left first molar: #26, maxillary left second molar: #27) was prepared simulating a section of the jaw. Samples were made with extracted human molars (Reference), crowned implants (Implant), or crowned resin tooth analogues (Tooth). Crowns (tooth #36; n = 16/material) were milled from lithium-disilicate (Li, IPS e.max CAD) or 3Y-TZP zirconia (Zr, IPS e.max ZirCAD, both Ivoclar Vivadent). Thermal cycling and mechanical loading (TCML) in the chewing simulator were applied simulating 15 years of clinical service. Wear traces were analyzed (frequency [n], depth [㎛]) and evaluated using scanning electron pictures. Wear results were compared by one-way-ANOVA and post-hoc-Bonferroni (α = 0.05). RESULTS. After TCML, no visible wear traces were found on Zr. Li showed more wear traces (n = 30-31) than the reference (n = 21). Antagonistic teeth #26 showed more wear traces in contact to both ceramics (n = 27-29) than to the reference (n = 21). Strong wear traces (> 350 ㎛) on antagonists and their adjacent teeth were found only in crowned groups. Abutment type influenced number and depth of wear facets on the antagonistic and adjacent teeth. CONCLUSION. The clinically relevant model with human antagonistic and adjacent teeth allowed for a limited comparison of the wear situation. The total number of wear traces and strong wear on crowns, antagonistic and adjacent teeth were influenced by crown material.

상악 제1 및 하악 제2 소구치의 발거를 이용한 교정치료 (ORTHODONTIC TREATMENT WITH UPPER FIRST AND LOWER SECOND PREMOLARS EXTRACTED)

  • 나종열;김태우;양원식
    • 대한치과교정학회지
    • /
    • 제26권1호
    • /
    • pp.113-124
    • /
    • 1996
  • 교정치료를 위한 상악 제1 소구치, 하악 제2 소구치의 발치는 한국인에서 II급 부정교합환자가 많지 않기 때문에 그리 흔하지 않다고 생각한다. 이와 같은 발치는 다음과 같은 장점을 제공할 수 있다. 첫째, 하악 전치를 약간만 retraction을 하며, 주로 하악의 구치부를 전방이동하여 II급 관계의 key correction을 손쉽게 할 수 있다. 둘째, 하악 전치의 과도한 설측경사가 일어남을 방지한다. 이는 하악 안모의 심한 변화를 방지하여 준다. 단점으로는 하악 제1 대구치의 근심경사를 들 수 있으며 이는 적절한 mechanics의 사용으로 방지하여 줄 수 있다. 본 증례들은 II급 1류의 특성을 가진 환자들로서 상악 제1 소구치, 하악 제2 소구치의 발치를 이용하여 교정치료를 하여 비교적 양호한 결과를 얻어 다음과 같이 보고하고자 한다.

  • PDF

Sex-, growth pattern-, and growth status-related variability in maxillary and mandibular buccal cortical thickness and density

  • Schneider, Sydney;Gandhi, Vaibhav;Upadhyay, Madhur;Allareddy, Veerasathpurush;Tadinada, Aditya;Yadav, Sumit
    • 대한치과교정학회지
    • /
    • 제50권2호
    • /
    • pp.108-119
    • /
    • 2020
  • Objective: The primary objective of this study was to quantitatively analyze the bone parameters (thickness and density) at four different interdental areas from the distal region of the canine to the mesial region of the second molar in the maxilla and the mandible. The secondary aim was to compare and contrast the bone parameters at these specific locations in terms of sex, growth status, and facial type. Methods: This retrospective cone-beam computed tomography (CBCT) study reviewed 290 CBCT images of patients seeking orthodontic treatment. Cortical bone thickness in millimeters (mm) and density in pixel intensity value were measured for the regions (1) between the canine and first premolar, (2) between the first and second premolars, (3) between the second premolar and first molar, and (4) between the first and second molars. At each location, the bone thickness and density were measured at distances of 2, 6, and 10 mm from the alveolar crest. Results: The sex comparison (male vs. female) in cortical bone thickness showed no significant difference (p > 0.001). The bone density in growing subjects was significantly (p < 0.001) lower than that in non-growing subjects for most locations. There was no significant difference (p > 0.001) in bone parameters in relation to facial pattern in the maxilla and mandible for most sites. Conclusions: There was no significant sex-related difference in cortical bone thickness. The buccal cortical bone density was higher in females than in males. Bone parameters were similar for subjects with hyperdivergent, hypodivergent, and normodivergent facial patterns.

Clinical Usefulness of the Jones Jig Appliance for Alignment of Premolars and Molars: Case Reports

  • Wonkyu Shin;Hyuntae Kim;Ji-Soo Song;Teo Jeon Shin;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Hong-Keun Hyun
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.99-108
    • /
    • 2024
  • Early loss of the primary maxillary second molar can lead to complications in which mesial drift of the adjacent first molar (M1) can disturb eruption of the succedaneous second premolar (P2). This study reports two cases of space loss for P2 caused by early exfoliation of its predecessor. After the eruption of the first premolar, the Jones jig appliance was used to distalize M1 and regain space for the eruption of P2. The appliance was further utilized to align the palatally erupted P2 into the dental arch. In both cases, the space and corrected position of P2 were well maintained. Early exfoliation of the primary second molar caused by mesial encroachment of M1 is a common phenomenon, and pediatric dentists should attend to this during routine examinations. An appropriate intervention should be initiated when the primary second molar is lost during the mixed dentition period. If used with careful anchorage control, the Jones jig appliance can effectively resolve this problem.

CSP 를 이용한 정밀부착형 국부의치에 관한 임상적 연구 (A Clinical Study on CSP Attachment Partial Denture)

  • 김광남
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.7-16
    • /
    • 1981
  • The technology of precision attachments has developed at such a pace that from a very few T-shaped attachments and bar attachments from the years 1915 to 1935 since removable bridge utilizing a T-shaped intracoronal attachment was constructed by Dr. Herman E.S. Chayes in 1906. There are now more than 120 models of the most diversified designs, ready made or laboratory fashioned. In 1971, 126 attachments were listed and classified by Mensor in his E M Attachment Selector. This selector consists of five charts giving specifications as to type, vertical dimensions, application, type of resilience, size of movement, type of retention and type of material and alloy. Thus the E M Attachment Selector is a useful guide for dentists to choose the attachment for his patients. But dentists should apply the attachment in each patient's case according to an accurate diagnosis and treatment plan. This paper is a case report of removable partial dentures utilizing CSP, PD and Bar attachment on a patient who needed full mouth reconstruction. Patient has right first, second molar and left first molar on the upper arch and also left first molar, first premolar and right canine on the lower arch. (Fig. 5)All remaining teeth are relatively healthy in their supporting tissues. On upper arch, ring shape CSP attachment was designed on left first molar and modified ring shape CSP attachment was designed on right first and second molar as the direct retainer of the removable partial denture. Full palatal coverage was used as the major connector in this case. (Fig. 23) On lower arch, author first splinted with a fixed bridge between left first molar and second premolar and a splint bar between left second premolar and right canine. (Fig. 11) A lower removable partial denture in which was designed with an Aker clasp on the left first molar and a PD attachment on .the right canine was constructed. (Fig. 17) This denture could get additional support from anterior splint bar. After both removable partial dentures were delivered to the patient (Fig. 26), author evaluated function of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of this case was excellent.

  • PDF