• Title/Summary/Keyword: SecY

Search Result 5,778, Processing Time 0.044 seconds

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF

Effect of Ledebouriella seseloides Extracts on Lipid Parameters in Ovariectomized Rats (방풍나물 추출물이 난소절제 흰쥐의 혈중 지질 변화에 미치는 영향)

  • Jeon, Myeong-Jeong;Kim, Mihyang
    • Journal of Life Science
    • /
    • v.26 no.1
    • /
    • pp.83-90
    • /
    • 2016
  • This study was investigated the improvement effects of Ledebouriella seseloides (LS) ethanol extracts on lipid parameters in an ovariectomized animal model. Sixty, nine-week old female Sprague Dawley rats were randomly assigned to four groups as follows: sham-operated rats (SHAM), ovariectomized rats (OVX-CON) and ovariectomized rats that were treated with LS ethanol extracts (50 mg/kg/day and 200 mg/kg/day, respectively). The diets were fed to the rats for six weeks after their operation. The total-cholesterol and triglyceride contents on serum increased in the OVX-CON group compared to the SHAM group, but supplementation with the LS extract caused these factors to decrease. Notably, the serum LDL-cholesterol concentration in the supplemented 200 mg/kg/day LS ethanol extract group was significantly more reduced than the OVX-CON group. In addition, the platelet aggregation ability was lower in groups treated with LS than in the OVX-CON group. The alkaline phosphatase (ALP) activity was lower in the LS extract group compared to the OVX-CON group. Collagen content, in bone and cartilage, were reduced by ovariectomy, but the supplemented LS extract groups exhibited higher concentrations in their bones. According to these results, the improvement effects of LS extract on serum lipid parameters and osteogenesis in ovariectomized rats were illuminated.

Discrimination of Geographical Origin for Astragalus Root (Astragalus membranaceus) by Capillary Electrophoresis and Near-Infrared Spectroscopy (Capillary electrophoresis 및 근적외선분광분석기를 이용한 황기의 원산지 판별)

  • Kim, Eun-Young;Kim, Jung-Hyun;Lee, Nam-Yun;Kim, Soo-Jeong;Rhyu, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.818-824
    • /
    • 2003
  • Capillary electrophoresis (CE) and near-infrared spectroscopy (NIRS) were performed to discriminate astragalus roots (Astragalus membranaceus) according to geographical origin (domestic or foreign). Two-hundred-and-four astragalus roots were extracted with 30% methanol in 0.1 M phosphate buffer (pH 2.5) and separated in a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis included: temperature $-45^{\circ}C$, voltage -14 kV, and pressure injection time -8 sec. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 40 mM hexane sulfonic acid with 20% 2-methoxy ethanol. Raw NIR spectra were obtained using NIRS, and modified partial least square regression was used to develop the prediction model. The correlation coefficient and standard error of prediction were 0.915 and 14.3%, respectively. Under the optimal conditions established for CE and NIRS, the geographical origins of the astragalus roots were correctly identified in 80 and 97%, respectively. Astragalus roots that were not discriminated by NIRS were correctly discriminated by CE. Hence, CE and NIRS are potential methods for discriminating the geographical origins of astragalus roots that complement one another.

Studies on Food Preservation by Controlling Water Activity III. Quality Changes of Fish Meat during Drying and Storage (식품보장과 수분활성에 관한 연구 3. 어육의 건조 및 저장중의 품질)

  • HAN Bong-Ho;LEE Jong-Gab;BAE Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 1983
  • A study on the qualify changes of fish meat during drying and storage has been carried out with filefish meat. Filefish meat was dried in a forced air dryer at 40 and $55\%$ for 20 hours with an air velocity of 0.4 m/sec under different conditions of relative air humidities in the range of 10 to $50\%$. The dried fish meat was stored at $30^{\circ}C$ in chambers with constant relative humidities controlled by the use of conditioned air stream passing through the saturated salt solutions. The qualify of filefish meat was evaluated with the brown color densities developed by lipid oxidation and Maillard reaction. Changes of viable cell count during drying and storage were also discussed. The predominant reaction for the brown color developed during the study period was the lipid oxidation. The lipid oxidation rate during drying at constant temperature was appreciably affected by water activities at the drying surfaces of filefish meat during the falling drying rate period. The lipid oxidation rate was the slowest under the condition of the relative air humidity of around $30\%$. In samples stored at water activity of 0.33, the lipid oxidation rate was retarded remarkably in comparison with the samples with lower or higher water activities. The addition of $1\%$ table salt, $1.5\%$ D-sorbitol and $6\%$ sucrose slightly lowered the water activity with the slowest lipid oxidation rate. Such additives resulted the increase of the water soluble brown color densities, which seemed due to the increase of mobility of the water soluble substances by the result of the increase of equilibrium water content. Microflora of the samples immediately after drying consisted of ca. $30\%$ of coccus types, ca. $65\%$ of rod types and ca. $5\%$ of molds and yeasts. During the storage of the samples with a water activity of 0.76, the ratio of the coccus types to the total microflora was increased remarkably while that of the Gram negative non-spore rod types was decreased. The ratios of the Gram positive rod types, molds and yeasts during the storage were nearly constant.

  • PDF

Physicochemical Properties of Added Sugar Ratio on Gugija-Sugar Leaching by Using Gugija (Lycii fructus) Raw Fruit (구기자생과를 이용한 구기자청 제조시 당첨가량에 따른 이화학적 특성)

  • Lee, Ka-Soon;Kim, Gwan-Hou;Kim, Hyun-Ho;Lee, Hee-Chul;Paik, Seung-Woo;Lee, Sox-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.6
    • /
    • pp.744-751
    • /
    • 2008
  • Physicochemical properties of Gugija-sugar leaching were investigated by adding sugar ratio on Gugija (Lycii fructus) raw fruit. Gugija were prepared by parboiling ($40{\sim}50$ sec at $85^{\circ}C$) and unparboiling. Gugija-sugar leaching were leached after preserving (5 months at $5^{\circ}C$) Gugija-sugar mixture (20, 40, 60, 80 and 100% sugar based on raw Gugija). The yield increased with UPRGSL-4 (Gugija-sugar leaching adding 80% sugar) having the highest yield at 77.5%; in contrast, total acidity decreased with increasing ratio of sugar. The main organic acids of raw Gugija are tartaric acid (0.63%), citric acid (0.57%), malic acid (0.54%) and succinic acid (0.3%). Citric acid and succinic acid decreased with increasing ratio of sugar but malic acid and tartaric acid increased on Gugija-sugar leaching. Polyphenolics and betaine content of unparboiling Gugija-sugar leaching decreased as increase ratio of sugar but in term of used Gugija amount, betaine content of each Gugija-sugar leaching was equal to raw Gugija. Also, parboiling Gugija-sugar leaching decreased quickly with increasing ratio of sugar, especially PRGSL-4 and PRGSL-5 (parboiling Gugija-80 and 100% sugar leaching, respectively) was not determined. 15 types of free amino acids were detected in raw Gugija; the total content was 601.6 mg/100 g and the highest amino acid among them was serine, 218.1 mg/100 g. In PRGSL-4 prepared by parboiling, 9 kinds of free amino acid were detected and the total content was 383.3 mg/100g. Also, in UPRGSL-4 (unparboiling Gugija-80% sugar leaching), all 17 kinds were detected and its total content was 705.7 mg/100 g.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Studies on the Induction of Available Mutant of Acetic Acid Bacteria by UV-light Irradiation and NTG Treatment. - The Selection of Mutant Strains and Various Conditions for Acetic Acid Production - (Acetobacter sp.와 그 변이주(變異株)를 이용(利用)한 식초산(食酢酸) 발효(醱酵)에 관한 연구(硏究) - 변이주(變異株)의 선정(選定) 및 생산조건(生酸條件) -)

  • Kim, Chan Jo;Park, Yoon Joong;Lee, Seuk Keun;Oh, Man Jin
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.169-175
    • /
    • 1980
  • These studies were conducted to induce the available mutant strains in acetic acid bacteria by the irradiation of UV-light and the treatment of N-methyl-N'-nitro-N'-nitrosoguanidine. 109 strains which were capable of producing acid in the ethanol containing medium were isolated from vinegar and Kimchi collected from the region of Daejeon city. From the collection T-50 strain was identified to have a strong fermentation power and selected as a mother strain for the study. Two mutants were obtained by treating T-50 strain with UV and NTG, and these mutants had a rapid acid production in the initial stage. The study was then made to compare the basic condition for acetic acid production of the mother strain and two mutant strains. The summarized results were as follows; 1. The isolated strain (T-50) was identified as Acetobacter aceti by Bergey's manual and Acetic acid bacteria (Tokyo Univ. press). 2. The selected strain was died completely when the strain was irradiated with 15 W UV-light at a distance of 45 cm for 160 seconds. 3. The mutants such as U-48 and N-67 were rapid in the acetic acid production at the initial stage compare to the mother strain. 4. Acetic acid formation by the shaking culture method was maximized in 2 days culture, and the optimal temperature for acetic acid production was $30^{\circ}C$. 5. Acetic acid was effectively produced by the addition of 0.1% ammonium sulfate as a nitrogen source and was also produced rapidly by the addition of 0.1% glucose.

  • PDF

Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine (냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.265-278
    • /
    • 1986
  • This study was attempted to improve the thermal efficiency of 6 kW water-cooled diesel engine on power tiller. The engine performance tests were conducted to find out the effect of cooling water capacity of 2700cc, 2800cc, 2900cc, 3000cc, 3100cc on power, brake specific fuel consumption (BSFC), torque, temperature of cooling water and lubricating oil and friction losses of the engine with D. C. dynamometer. The results obtained in the study are summarized as follows: 1. The performance of the engine tested was adequated to Korea Industrial Standard but actual economy power was 10% higher than the labeled rated power of the engine. The BSFC of the engine tested 297.8g/kW-h which is belong a little higher level than hreign products. The temperature of cooling water was $101^{\circ}C$ which is higher than SAE standard ($88^{\circ}C$) 2. The friction losses of engine tested was 3.656 kW at 2200 rpm of rated rpm (piston speed 6.97m/sec) and is higher than those of foreign products. 3. When the cooling water capacity was increased from 2700cc to 3100cc the power output of the engine was increased from 6.7 kW to 7.13 kW at the rate of 6.4% and also the torque of the engine was increased from 28.85 N.m to 30.76 N.m at the rate of 6.39%. 4. When the cooling water capacity was increased from 2700cc to 3100cc, the BSFC was decreased 6.9g/kW-h from 310.9g/kW-h to 304.1g/kW-h, and after one half hour operation with full load, the temperature of cooling water was decreased $13^{\circ}C$ from $101^{\circ}C$ to $88^{\circ}C$ and also the temperature of lubricant oil was decreased $6.4^{\circ}C$ from $76.7^{\circ}C$ to $70.4^{\circ}C$. 5. The mechanical efficiency was increased from 70.08% to 71.08% when the cooling water capacity was increased from 2700cc to 3100cc.

  • PDF