• Title/Summary/Keyword: Seawater desalination

Search Result 193, Processing Time 0.021 seconds

Performance Evaluation of Multi Effect Distillation for Solar Thermal Desalination (태양열 해수담수화를 위한 증발식 다중효용 담수기 성능평가)

  • Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.74-79
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3/day$ capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3/hour$ sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8m^3/hour$ for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3/day$ of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.

  • PDF

Analysis of the ejector for low-pressure evaporative desalination system using solar energy (태양에너지 이용 저압 증발식 해수 담수시스템 이젝터 CFD 해석)

  • Hwang, In-Seon;Joo, Hong-Jin;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.137-143
    • /
    • 2010
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube(throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. In the present study, the multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Two-dimensional geometry was considered with the quadrilateral-mashing scheme. The gas suction rate increases with increasing Motive flow circulating rate.

Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment

  • Yang, Heungsik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Seawater desalination is doubtlessly a viable option to supply fresh drinking water. Nevertheless, RO (reverse osmosis) desalination plants in specific areas may be intermittently operated to match the imbalance between water demand and supply. Although a handful of works have been done on other membrane systems, few studies have attempted to mitigate fouling in intermittent RO systems. Accordingly, the objectives of this paper were to examine the effect of the intermittent operation on RO fouling; and to compare four intermittent operation modes including feed solution recirculation, membrane storage in the feed solution, deionized water (DI) recirculation, and membrane storage in DI water. Results showed that intermittent operation reduced RO fouling under several conditions. However, the extents of fouling mitigation were different depending on the feed conditions, foulant types, and membrane lay-up methods. When the feed solution was recirculated during the lay-up, the restoration of the flux was less significant than that by the feed solution feed-up. The use of deionized water during the lay-up was effective to restore flux, especially when the feed solution contains scale-forming salts (CaSO4) and/or colloidal silica.

Recent Progress of Membrane Technology and its New Application for Water Treatment

  • Hiroyuki, Yamamura;Yoshinari, Fusaoka;Masaru, Kurihara
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.81-94
    • /
    • 1998
  • Nowadays, membrane separation such as reverse osmosis (RO) and ultrafiltration (UF) play an important role in the industrial separation technology. Among desalination technologies available today, reverse osmosis is usually the most economical process for wide range of water salinity. Main applications include production of high purity water, desalination of seawater and brackish water for a drinking water supply, treatment of waste water for environmental protection, and recovery of precious materials from industrial waste water. In this paper, we will mention membrane performance and these practical use focused on reverse osmosis membranes and ultrafiltration membranes recently developed by Toray.

  • PDF

Applicability of Mineral-controled Water from Deep Ocean Water for Industrial Utilization (해양심층수 수질조정수의 산업소재 적용성 평가)

  • Kim H.J.;Moon D.S.;Cho S.Y.;Lee Y.S.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.23-28
    • /
    • 2004
  • Various merchandises have appeared in recent markets of mineral water, beverage, food and cosmetics etc. These are almost manufactured by adding raw seawater, desalinated water, brine or salt from Deep Ocean Water(DOW), and it intimated desalination and mineral extraction are key techniques for DOW business. This study aims to verify the functional performance of mineral-controlled water produced by the basic methods which were proposed by authors for industrial purposes. This water revealed the possibility of the radical scavenging effects and moisturizing capability.

  • PDF

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.

Removal Characteristics of Boron and Humic Acid by Pre-blending Seawater and Brackish Water Using UF-SWRO Hybrid Process in Pilot-scale Plant for Desalination (UF-SWRO 혼합공정을 이용한 해수담수화 파일럿 플랜트에서의 해수와 기수의 블렌딩을 통한 보론 및 휴믹산 제거 특성)

  • Kim, Won-Kyu;Shin, Sung-Hoon;Lee, Haksu;Woo, Dal-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • Using UF-SWRO hybrid process, pre-blending tests of seawater and brackish water were performed to investigate the effects on removal of boron and humic acid (HA). Feedwater pre-blending was set based on TDS concentration from 15,000 mg/L to 27,000 mg/L and analyzed for boron removal characteristics. Also organics rejection at same TDS concentration range was investigated by injecting HA. Boron concentration appeared to be high as TDS concentration was high ranging from 76.60% to 83.27%, but boron concentration in final produced water was increased up to 0.69 mg/L from 0.48 mg/L. In cases of HA tests at 10 mg/L, 22,500 mg/L TDS appeared to be higher removal rate of 17.59% than a very poor result of 8.43% in 27,000 mg/L. But high HA removal rate of 57.14% was obtained in produced water with 22,500 mg/L TDS containing 10 mg/L of HA and 27,000 mg/L TDS yielded lower boron removal rate of 54.49%. Meanwhile it was found that a relatively high flux and recovery rate were obtained following process when feedwater was injected with HA. It is considered that most of fouling substances were eliminated by binding between HA and $Ca^{2+}$. Thus, when desalination using UF-SWRO with respect to boron and HA, TDS concentration is determined to be advantageous as lower.

Toxicity and Behavioral Changes of Medaka (Oryzias latipes) by Brine Exposure (송사리(Oryzias latipes)를 이용한 고염해수의 생태독성 및 단기적 행동변화에 관한 연구)

  • Yoon, Sung-Jin;Park, Gyung-Soo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • Acute toxicity test and behavioral change analysis of seawater acclimated Japanese medaka were conducted to identify the brine effects on fish by seawater desalination. 7 day acute toxicity test of brine revealed linear concentration-response relationship from 40.0~80.0 psu treatment groups. There was no significant brine effect for 30-40 psu groups and mass mortality was observed from >50 psu exposure (7-day $LC_{50}$=51.4 psu). Images from the real time camera system were analyzed to observe the changes in behavioral patterns of medaka exposed to various salinity. 40.0 and 50.0 psu exposed groups were stabilized in behavioral patterns after 3.1 and 4.6 hours, respectively and 60.0 psu group showed sharp increase in activity during first 12 hours and 50% mortality thereafter. Similar patterns were observed to 70 and 80 psu groups and both experimental groups showed 100% mortality within 12 hours. Acute toxicity test and behavioral patterns showed very similar toxicity results which revealed the increases in mortality and behavioral activities from 50.0 psu. This critical salinity for fish impacts must be implemented to brine discharge strategy by seawater desalination into the coastal area. Also, we recommend that real time camera monitoring system must be a useful tool for early warning of fish toxicity for other applications. This research was funded by Ministry of Land, Transport and Maritime Affairs, Korea.

Optimum Operating Condition for Micro-Filtration Process as a Seawater Desalination Pretreatment (해수담수화 전처리로서 가압식 MF 공정의 최적 운전조건 도출)

  • Kim, Youngmin;Jang, Jung-Woo;Kim, Jin-Ho;Choi, June-Seok;Lee, Sangho;Kim, Sukwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.624-629
    • /
    • 2013
  • The relation between performance maintenance conditions and those cost efficiency was studied to choose an optimum operating condition in the seawater desalination pretreatment system. A hollow fiber microfiltration module, which was developed with domestic technology, was tested with the various operating conditions such as chemically enhanced backwash cycles and design dosages of a cleaning chemical. Transmembrane pressure was measured to investigate membrane fouling status and cleaning degree. In addition, economic analysis was performed to compare water production costs by the operation condition. As a result, The operation mode III, chemically enhanced backwash at once a day with 100 mg/L of sodium hypochlorite (NaOCl) was selected. The concurrent evaluation between membrane filtration performance and its economic analysis will be suitable to choose an efficient optimum condition.

Development of minimum-salinity feedwater for reduction of unit production cost of reverse-osmosis desalination plants (역삼투 담수화 시설의 생산단가 절감을 위한 저 염도 지하 기수 개발)

  • Park, Namsik;Jang, Chi Woong;Babu, Roshina
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.431-438
    • /
    • 2016
  • Large energy consumption is one of the main weaknesses of RO desalination. A new method is proposed to reduce the energy consumption of RO desalination which depends on the salinity of the feedwater. Low salinity feedwater can be obtained using groundwater wells which extracts both fresh groundwater and subsurface sea water. Subsurface feedwater is advantageous in overcoming other problems associated with surface seawater intakes. Salinities of groundwater depend on a number of factors. In this work a new simulation-optimization model is proposed to identify well locations and pumping rates with would provide the required design flow rate with the minimum salinity. When groundwater is developed in a coastal area, the saltwater wedge advances inland and may contaminate existing groundwater wells, which must be prevented. The model can protect existing wells while developing minimum salinity feedwater. Examples are provided to demonstrate the usage of the model.