• Title/Summary/Keyword: Seat contact pressure

Search Result 19, Processing Time 0.033 seconds

Analysis of the Room Temperature Fitting Process for Assembling the Part(Valve Seat and Cylinder Head) (Valve Seat/Cylinder Head 단품조립을 위한 상온압입공정 해석)

  • Bae, J.H.;Kim, M.S.;Woo, T.K.;Kim, T.J.;Ho, J.D.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.607-616
    • /
    • 2009
  • There are three sub-processes associated with the assembly of the valve seat and cylinder head; heat fitting, cold fitting, and shrink fitting. In the heat fitting stage, the cylinder head is heated to a specified temperature and then squeezed toward the outer diameter of the valve seat. The cold fitting process cools the valve seat and safely squeezes it toward the inner diameter of cylinder head. However, these methods increased the installations & running cost and curtailed productivity. To address these problems, we analyzed the shrink fitting process using the contact pressure caused by fitting interference between the outer diameter of the valve seat and the inner diameter of the cylinder head. In this study, a closed form equation for predicting the contact pressure and fitting load is proposed. For quality control of the assembly line, principal factors of the shrink fitting process influenced in contact pressure were simulated by the FEM. Actual loads measured in the field showed good agreement with the results obtained by theoretical and finite element analysis.

Ergonomic Evaluation of Trunk-Forearm Support Type Chair

  • Lim, Seung Yeop;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.143-153
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effects of trunk-forearm supported sitting on trunk flexion angle, trunk extensor fatigue and seat contact pressure. Background: The relationship between sitting posture and musculoskeletal disorders of the trunk extensor fatigue and seat contact pressure has been documented. The trunk-forearm support type ergonomic chair was devised from the fact that trunk-forearm support has been reported to reduce trunk extensor activity and discomfort. Method: Using three different sitting postures, upright ($P_1$), trunk-forearm supported ($P_2$) and normal sitting ($P_3$), six healthy subjects participated in the study. Motion capture system was used to collect head and trunk flexion angle, and surface electromyography (sEMG) was used to collect myoelectric signal of upper trapezius, lower trapezius, erector spinae, multifidus, and pressure mat system was used to measure seat contact pressure. Results: When trunk and forearm were supported by the ergonomic chair, higher head flexion angle showed upright > trunk-forearm supported > normal in order, and muscle fatigue showed less than upright and normal sitting. Mean seat contact pressure decreased 19% than upright sitting. But muscle fatigue was not affected by each condition. Conclusion: Trunk-forearm supported sitting of the ergonomic chair showed positive effect in respect of trunk and head flexion angle, trunk extensor fatigue, seat contact pressure. To acquire comprehensive understanding of the effectiveness of the ergonomic chair, further studies such as anatomical effects from measurement of external applied loading effect to the body from interface pressure analysis are required. Application: The results of the publishing trend analysis might help physiological effects of trunk-forearm support type chair.

Valve Seat Design for Full Contact Effect Using Grey Relational Analysis (회색 관계 분석법을 이용한 누수 방지용 밸브 시트 설계)

  • Lee, Jung-Hee;Kang, Gyeong-Ah;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • A glove valve regulates the flow in a pipeline as a kind of control valve. However, when the disc and seat contact, the valve structure can be distorted and flow can leak due to the elongation of the valve material under high pressure. The surface texture is not good enough to seal the contact surface (in practice) because the lapping process is usually done manually. Furthermore, assembly performance is analyzed by structural analysis. Compared with a standard seat, the newly designed seat had a smaller radial deformation and a larger longitudinal deformation. Therefore, the newly designed seat can maintain a tight and uniform contact with the disc with a reduced radial deformation and an expanded available seal area with an increased longitudinal deformation. The seal performance of the glove valve has been improved in a cost-effective manner.

The Study on the Evaluation of Contact Pressure of Wheelchair Seat Cushion (횔체어 시트쿠션의 접촉 압력 평가에 관한 연구)

  • Kang, Young-Sig;Yang, Sung-Hwan;Cho, Mun-Son;Sin, You-Min
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.61-69
    • /
    • 2010
  • The users who use the wheelchair are confined to a wheelchair for a long time. Accordingly, the use of seat cushion for pressure distribution is very important in order to prevent a bedsore. Therefore, this paper provides useful information for design of seat cushion through statistical testing among nothing cushion, low cell type of air cushion, high cell type of air cushion, and jelly type of air cushion. It turned out that the jelly type and high cell type of air cushion have a serious effect on decision and design of seat cushion.

  • PDF

Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Seo, Jihyeon;Lee, Byunghun;Lee, Dongkyu;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.279-282
    • /
    • 2020
  • In this study, body pressure was quantitatively detected using built-in optical sensors, inside an air cushion seat. The proposed system visualizes the effect of the body pressure distribution on the air cushion seat. The built-in sensor is based on the time-of-flight (ToF) optical method, instead of the conventional electrical sensor. A ToF optical sensors is attached to the bottom surface of the air-filled cells in the air cushion. Therefore, ToF sensors are durable, as they do not come in physical contact with the body even after repeated use. A ToF sensor indirectly expresses the body pressure by measuring the change in the height of the air-filled cell, after being subjected to the weight of the body. An array of such sensors can measure the body pressure distribution when the user sits on the air cushion seat. We implemented a prototype of the air cushion seat equipped with 7 ToF optical sensors and investigated its characteristics. In this experiment, the ToF optical pressure sensor successfully identified the pressure distribution corresponding to a sitting position. The data were accessed through a mobile device.

Seat Tightness of Flexible Metal Seal of Butterfly Valve at Cryogenic Temperatures (초저온 버터플라이 밸브용 탄성 메탈실의 누설방지에 관한 연구)

  • Ahn, Jun-Tae;Lee, Kyung-Chul;Lee, Yong-Bum;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.643-649
    • /
    • 2011
  • For the development of butterfly valves used in liquefied natural gas (LNG) vessels, the seat tightness is one of the important factors to be taken into account in the valve-design process. An O-ring-type metal seal with a retaining ring showing good seat tightness at cryogenic temperatures has been widely used, despite the high manufacturing costs involved. As an alternative, a flexible solid metal seal offers not only sufficient tightness of the butterfly valve, meeting specification requirements, but also relatively low manufacturing costs. In this study, a design criterion to ensure the seat tightness of the butterfly valve using the flexible solid metal seal is proposed. The contact pressure can be calculated by the simulation of the frictional contact behavior between the surface of the metal seal and the valve disc. The geometry of the flexible solid metal seal is determined so that it satisfies the design criterion for sufficient seat tightness, and is verified by experiments according to BS6755 and BS6364.

The Effect of Change Wheelchair's Seat of Polyurethane Foam Material on Sitting Pressure (폴리우레탄 폼 재질의 휠체어 좌석이 착석 압력에 미치는 영향)

  • Lee, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.205-211
    • /
    • 2014
  • The purpose of this document is to provide basic data helpful in selecting seating device material by examining the affects of polyurethane foam material on seating pressure. In order to achieve this study objective, four seats, 6cm in height, were produced in hardness of: 13, 28, 25, and $45kg/cm^2$. To measure the sitting pressure distribution (depending on the characteristics of the produced seats), 10 healthy subjects participated in the experiment. XSENSOR was used a measuring device, and each seat was mounted on a wheelchair simulation. By analyzing the obtained data with Average Pressure(AP), Peak Pressure(PP,), and Contact Area(CA), the sitting pressure was measured for five minutes on each seat. This experiment showed the following results: There were significant differences between the AP, PP, and CA in the seat material (p<0.5). While the hardness of $18kg/cm^2$ showed low pressure, the hardness of $45kg/cm^2$ showed high pressure. This study also showed that seat material made of polyurethane should be considered when selecting seats. If polyurethane foam is used in seat recommendations, it will be recommended to use $18kg/cm^2$ for the proper hardness of the seat material.

  • PDF

Numerical Study on the Sealing Safety of a Valve Packing in a LPG Cylinder (LPG 용기용 밸브패킹의 누설안전에 관한 수치적 연구)

  • Kim, Chung-Kyun;Kim, Tae-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.34-39
    • /
    • 2007
  • In this paper, the FEM result has been presented for a sealing safety between a valve packing and a valve seat during a open and close operation in a LPG cylinder. The sealing operation of a LPG valve is completed when the valve packing in which is made by a nylon-66 polymer is to stop a LP gas flow, which flows out from the outlet of a brass pipe in a LPG cylinder. The contact sealing mechanism of the valve may be classified by a flat contact of an unused valve packing and a circular groove contact of an used valve packing in a current LPG valve. Based on the FEM and experimental investigations the sealing force, 4.9 MPa for a flat contact mode of the unused valve packing is a little high compared to that of the used valve packing, which shows a circular groove contact geometry against a valve seat. But these sealing pressures for two contact modes are very low compared to the ultimate strenath 83 MPa of the nylon-66 and this may be designed with a excess strength of the valve.

  • PDF