• Title/Summary/Keyword: Seamless tube

Search Result 40, Processing Time 0.028 seconds

A Study on the Characteristics of Evaporative Heat Transfer for Carbon Dioxide in a Horizontal Tube (수평원관 내 이산화탄소의 증발열전달 특성 연구)

  • Cho, E.S.;Yoon, S.H.;Kim, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.104-107
    • /
    • 2000
  • Evaporative heat transfer characteristics of carbon dioxide has been investigated. Experiment has been carried out for seamless stainless steel tube with outer diameter of 9.55 mm and inner diameter of 7.75 mm. Direct heating method is used for supplying heat to the refrigerant was uniformly heated by electric current which was applied to the tube wall. The saturation temperature of refrigerant is calculated from the measured saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and heat conduction through the tube wall. Mass Quality of refrigerant was calculated by considering energy balance in the preheater and the test section. Heat fluxes were set at 12, 16, 20, 23, and $27kW/m^2$, mass fluxes were controlled at 212, 318, 424, and $530 kg/m^2s$, and saturation temperature of refrigerant were adjusted at 0, 3.4, 6.7 and $10.5^{\circ}C$. From this study, heat transfer coefficients of carbon dioxide have been provided with respect to quality for several mass fluxes, heat fluxes. Finally, the experimental results in this study are compared with the correaltion by Gungor and Winterton(1987).

  • PDF

Effect of Heat Treatment Conditions on Formability and Property of Warm Hydroformed Parts for Al 6061 Extruded Tube (Al6061압출재를 이용한 온간액압성형품의 성형성 및 물성에 미치는 열처리조건의 영향)

  • Yi, Hyae-Kyung;Kwon, Seung-O;Jang, Jeong-Hwan;Lee, Young-Seon;Moon, Young-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.4
    • /
    • pp.181-186
    • /
    • 2007
  • Effect of heat treatment conditions on formability and property of warm hydroformed parts for Al 6061 extruded tubes was investigated in this study. For the investigation, as-extruded, fully annealed and T6-treated Al 6061 seamless tubes were prepared. To evaluate the warm hydroformability, uni-axial tensile test and free bulge test were performed at various pre- and post-heat treatment conditions. And the tensile test specimens were obtained from hexagonal prototype hydroformed parts at $250^{\circ}C$. As a result, hydroformability of fully annealed tube is 25% higher than that of extruded tube. The tensile strength and strain of hydroformed part reach to 330 MPa and 12%, respectively, when the part was T6 treated after warm hydroforming. However, the hydroformability of T6 pre-treated tube is relatively low due to the decreased elongation, 8%.

A Study on the Safety Enhancement of Hydrogen Tube Trailer (수소운송설비 안전성 강화 방안 고찰)

  • Woo-Il, Park;Yeong-Hun, Kim;In-Woo, Lee;Seung-Kyu, Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.59-64
    • /
    • 2022
  • Currently, 787 hydrogen tube trailer are in operation as of the end of October 2022, and a maximum of 340 kg is transported in a Type 1 seamless container at a pressure of up to 200 bar. The current safety management system and facility management are in good condition, but the system and facility structure improvement are needed to strengthen safety. Accordingly, this paper simulated and analyzed an accident case that occurred on the Daejeon-Dangjin highway on December 28, 2021 during the process of expanding the supply and operation of hydrogen tube trailer according to the hydrogen energy activation policy. Based on the results, suggestions were made on how to improve the safety of hydrogen tube trailer.

An Analytical Study by Variation of Die and Plug Angle in Drawing Process for the Strength Optimization of Ultra High Pressure Common Rail Fuel Injection Tube Raw Material (초고압 커먼레일 연료분사튜브 원재료 강성 최적화를 위한 인발 공정에서의 Die와 Plug 각도 변경에 따른 해석적 연구)

  • Ahn, Seoyeon;Park, Jungkwon;Kim, Yonggyeom;Won, Jongphil;Kim, Hyunsoo;Kang, Insan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.338-344
    • /
    • 2016
  • The study is actively being performed to increase fuel injection pressure of common rail system among countermeasures to meet the emission regulation strengthen of the Diesel engine. The common rail fuel injection tube in such ultra high pressure common rail system has the weakest structural characteristics against vibration that is generated by fuel injection pressure and pulsation during engine operation and driving. Thus the extreme durability is required for common rail fuel injection tube, and the drawing process is being magnified as the most important technical fact for strength of seamless pipe that is the raw material of common rail tube. In this respect, we analyzed the characteristic of dimension and stress variation of the ultra high pressure common rail fuel injection tube by variation of Die and Plug angle in drawing process. Based on the analysis, we tried to obtain the raw material strength of common rail fuel injection tube for applying to the ultra high pressure common rail system. As a result, Plug angle is more important than entry angle of Die and we could obtain the target dimension and strength of the ultra high pressure common rail fuel injection tube through optimization of Plug angle.

A Study on Magnetic Abrasive using Sludge

  • Kim, Hee-Nam
    • Journal of the Speleological Society of Korea
    • /
    • no.82
    • /
    • pp.8-12
    • /
    • 2007
  • In this paper, we have investigated the characteristics of the magnetic abrasive using sludge on polishing of internal finishing of seamless stainless steel tube applying magnetic abrasive polishing. Either green carborundum(GC) grain was used to resin sludge at a low temperature, and the sludge of magnetic abrasive powder was synthesized and crushed into 200 meshes. Surface roughness was measured before and after polishing, and more than 38% of improvement of surface roughness was achieved when grain was used under a specific condition. Even though some degree of surface roughness due to deeper scratches still exist, but the result showed a prospective magnetic abrasive polishing using sludge with green carborundum grains.

Magnetic Abrasive Polishing for Internal Face of STS Tube using Sludge Abrasive Grain

  • Kim, Hee-Nam;Soh, Dea-Wha;Hong, Sang-Jeen;Lee, Byung-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.3
    • /
    • pp.128-132
    • /
    • 2005
  • In this paper, we have investigated the characteristics of the magnetic abrasive using sludge on polishing of internal finishing of seamless stainless steel (STS304) tube applying magnetic abrasive polishing. Either white alumina (WA) or green carborundum (GC) grain was used to resin sludge at a low temperature, and the sludge of magnetic abrasive powder was synthesized and crushed into 200 meshes. Surface roughness was measured before and after polishing, and more than $40\%$ of improvement of surface roughness was achieved when WA grain was used under a specific condition. Even though some degree of surface roughness due to deeper scratches still exist, but the result showed a prospective magnetic abrasive polishing using sludge with WA or GC grains.

Numerical and Experimental Study of U-Bending of SUS304L Heat Transfer Tubes (SUS304L 튜브의 U-Bending 성형공정에 관한 해석적·실험적 연구)

  • Kim, Y.B.;Kang, B.S.;Ku, T.W.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.405-412
    • /
    • 2014
  • As a major type of heat exchanger, the steam generator (SG) produces steam from heat energy of a nuclear power plant reactor. The steam produced by the steam generator flows into a turbine, and plays an important role in electric power generation. The heat transfer tubes in the steam generator consist of approximately 10,000 U-shaped tubes, which perform a structural role and act as thermal boundaries. The heat transfer tubes conduct the thermal energy between the primary coolant (about $320^{\circ}C$, $157kgf/cm^2$) obtained from the reactor and the secondary coolant (about $260^{\circ}C$, $60kgf/cm^2$) as part of the secondary system. Recently, the heat transfer tubes in the steam generator of the pressurized water reactor (PWR) are primarily produced from Alloy 600 and Alloy 690 seamless tubes. As a pilot study to find process parameters for the cold U-bending process using rotary draw bending, numerical and experimental investigations were conducted to produce U-shaped tubes from long straight SUS304L seamless tubes. 3D finite element simulations were run using ABAQUS Explicit with consideration of the elastic recovery. The process parameters studied were the angular speed, the operation period and the bending angle. Experimental verifications were conducted to insure the suitability of the final U-shaped configurations with respect to both ovality and wall thickness.

Development of Hybrid Rocket(KHyRoc-II) with 1000 kgf Thrust level (추력 1000 kgf급 하이브리드 로켓(KHyRoc-II)의 개발)

  • Moon, Keun-Hwan;Oh, Ji-Sung;Rhee, Sun-Jae;Choi, Won-Jun;Kim, Hak-Chul;Lee, Jung-Pyo;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.58-62
    • /
    • 2012
  • In this study, the hybrid rocket was developed that has a thrust of 1000 kgf level. The static fire test was shown that the thrust was 700 kgf level and trajectory was predicted by the maximum altitude of 12.5 km. The L/D ratio of KHyRoc-I has 28, but the KHyRoc-II were designed the small L/D ratio(18.3) using the seamless aluminium tube(Diameter : 250 mm). And KHyRoc-II has a thrust of 900 kgf level, that is designed with internal ballistics and trajectory was predicted by the maximum altitude of 7.4 km.

  • PDF

Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube (순수 및 혼합냉매의 원관내 증발열전달 실험)

  • Sin, Ji-Yeong;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

An Experimental Study on the Characteristics of Evaporative Heat Transfer of Carbon Dioxide (이산화탄소의 증발열전달 특성에 관한 실험적 연구)

  • 조은석;윤석호;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.38-45
    • /
    • 2002
  • Evaporative heat transfer characteristics of carbon dioxide have been investi- gated by experiment. The experiments have been carried out for a seamless stainless steel tube of the outer diameter of 9.55 mm, the inner diameter of 7.75 mm and the length of 5.0 m. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Experiments were conducted with$CO_2$of purity 99.99% at saturation temperatures of 0.0 to 10.5$^{\circ}C$, heat fluxes of 12 to 27kW/$m^2$s and mass fluxes of 212 to 530 kg/$m^2$s. The heat transfer coefficients of $CO_2$are decreased as the vapor quality increases and these phenomena are explained by dimensionless Weber and Bond numbers. The heat transfer coefficients of$CO_2$increase when the heat and mass fluxes increase, and the saturation temperature effects are minor in the test range of this study. The present experimental data are compared with six renowned correlations with root-mean-squared deviations ranging from 23.0 to 94.9% respectively.