• 제목/요약/키워드: Sealing surface

검색결과 242건 처리시간 0.029초

ECL용 유리기판의 레이저 저온 실링처리 (The Low Temperature Laser Treatment of Sealing Glass Substrate for ECL)

  • 최혜수;박차수;곽동주;성열문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1134-1135
    • /
    • 2015
  • In this paper, we reported fabrication of sealing the glass substrate using laser treatment at low temperature for electrochemical luminescence (ECL) cell. The laser treatment at temperature is using laser diode. The glass substrate sealing by laser treatment tested at 1-5 W, 1-5 mm/s for builted and tested. The sealing laser treatment method will allow associate coordination between the two glass substrate was enclosed. The effect of laser treatment to sealing the glass substrate was found to have cracks and air gap at best thickness of about $845-780{\mu}m$ for condition 5 W, 1-5 mm/s. The surface of sealing was roughness which was not influent to electrodes So, it is more effective viscosity between two glasses substrate.

  • PDF

폴리실라잔계 실란트를 이용한 정전척 실링특성 향상 연구 (Improvement of Sealing Property of Electrostatic Chuck by Applying Polysilazane Sealant)

  • 최재영;박현수;손민규;정창오;김우병
    • 한국표면공학회지
    • /
    • 제49권6호
    • /
    • pp.567-574
    • /
    • 2016
  • We have analyzed chemical properties of polysiloxane and polysilazane films, respectively, as sealing materials for electrostatic chuck (ESC) and have investigated the possibility of polysilazane as an alternative sealant to polysiloxane. It has been revealed that Si-O with organic bonding ($Si-CH_3$) existed in polysiloxane films compared to only pure Si-O bonding in polysilazane films. The sealing property of polysilazane has been found outstanding even in a short time of application. In the polysiloxane films containing $H_2O$, pin holes have been found possibly due to $CO_2$ gas evolution, and low adhesion with Si substrate has been observed after heat stress test in connection with the existence of organic bonding. After acid resistance test in 0.5 vol.% HF, 68 wt.% $HNO_3$, and 37 wt.% HCl solution, polyilazane films have shown a longer survival times. Compared to the conventional polysiloxane sealant, polysilazane is expected as a new sealing material because of good thermal and chemical stability.

FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석 (Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV)

  • 이정민;정화정;전문수;이형욱
    • 소성∙가공
    • /
    • 제27권1호
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

비선형 접촉문제 해석을 통한 얼음 디스펜서 덕트 캡 조립체의 밀봉성능 평가 및 개선방안 연구 (A Study on Evaluation and Improvement of Sealing Performance of Duct Cap Assembly for Ice Dispenser By Nonlinear Contact Problem Analysis)

  • 이부윤
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.37-46
    • /
    • 2018
  • Present research is to evaluate and improve the sealing performance of the duct cap assembly for the ice dispensers through structural analysis. The nonlinear contact problems to check the sealing performance were analyzed using ANSYS software. The results of the analyses related to the sealing performance: the displacement distribution, the contact condition between the cap-silicon and the case, and the pressure distribution on the contact surface, were examined and discussed. Based on the results of the existing design of the duct cap assembly, two cases of the design modifications to improve the sealing performance were introduced. By examining the results of the two cases, a final design improvement plan was proposed and analyzed. It is shown that the sealing performance of the proposed final design is much more favorable than the existing design. The method of structural analysis and design improvement of the duct cap assembly presented in this paper will help improve the sealing performance of the ice dispenser duct caps.

치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과 (SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING)

  • 김민정;이미정;유미경;박수정;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.22-30
    • /
    • 2005
  • 수복물의 변연 미세 누출과 마모 개선을 위해 표면 전색제가 개발되었으며 이의 효과에 대해 알아보기 위해, 규격화된 치경부 5급 와동을 25개의 소구치의 협면에 형성하고 Single Bond와 Z-250으로 수복한 뒤, $37^{\circ}C$의 증류수에 7일간 보관한 후 무작위로 5군으로 나누고 다음과 같은 재료로 제조사의 지시에 따라 표면 처리하였다 : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. 그 후 잇솔질 마모시험을 시행하였다. 표면 조도는 잇솔질 전후에 profilometer로 측정되었고 paired t-test와 ANOVA로 비교하였다. 접착면과 표면변화는 전자현미경으로 관찰하였다. 미세누출 평가를 위해 시편은 $2\%$ methylene blue 용액으로 염색한 뒤, 협설로 잘라 제작하였다. 입체현미경을 이용하여 교합면쪽과 치경부쪽 계면에서 미세누출을 관찰하고 Kruskal-Wallis와 Mann-Whitney U test를 이용하여 그 결과를 비교하였다. 표면 조도는 잇솔질 후 수치가 증가하였으나 통계학적으로 유의한 차이를 나타내지는 않았다. 전자 현미경 관찰 결과, 표면 전색제가 접착면에 부분적으로 남아있기도 하였으나 많은 부분에서 떨어져 나간 상태였다. 특히, 미세 틈새가 치경부쪽 변연에서 나타났다. 미세누출 실험에서는 법랑질에서 더 봉쇄효과가 좋았으며 교합면쪽 변연에서 군간에 유의할만한 차이를 나타내었다. 조절군과 Single Bond를 도포한 군에서는 치경부쪽 변연보다 법랑질쪽 변연에서 유의하게 좋은 변연 봉쇄 효과를 나타내었다.

시일과 코팅된 스틸면 사이의 구형 입자에 의한 미끄럼 접촉 해석 (Sliding Contact Analysis of a Spherical Particle between Rubber Seal and Coated Steel Counterface)

  • 박태조;이준혁
    • Tribology and Lubricants
    • /
    • 제28권6호
    • /
    • pp.283-288
    • /
    • 2012
  • In this study, a new sliding contact problem involving an elastomeric seal, a spherical particle and a hard coated steel counterface was modeled to investigate the detailed wear mechanisms related to the sealing surface. The model was also used to design the optimum coating conditions. A three-dimensional finite element contact problem was modeled and analyzed using the nonlinear finite element code, MARC. The deformed steel surface and stress distributions are presented for different coating layers and thicknesses. When the coating thickness is relatively small, the entrapped particle produces surface plastic deformations such as groove and torus. In addition, the sealing surface can be damaged by abrasive wear as well as fatigue wear. For a relatively thick and multi-layered coating, on the other hand, surface plastic deformation does not occur, and the amount of abrasive and fatigue wear is reduced. Therefore, the proposed contact model and results can be used in the design of various sealing systems, further intensive studies are required.

마찰접촉조건에 따른 소수력 수차용 밀봉장치의 마찰.마멸특성 연구 (A Study on the Friction and Wear Characteristics of Contact Sealing Units for a Small Hydro-power Turbine Under Various Rubbing Conditions)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제22권6호
    • /
    • pp.314-319
    • /
    • 2006
  • In this paper, the friction and wear characteristics of contact type sealing unit far a water turbine have been presented. The sealing unit for a small hydropower generation is to stop a leakage of circulating water from an outside of an impeller to an inside of a rolling bearing. The friction heating between a seal ring and a seal seat may radically increase a surface temperature in which increase a power loss and wear on the rubbing surface. The surface wear strongly affect to the seal life of a mechanical face seal. In this study, the hardness of a stainless steel in which is a heat-treated is 892.8 in Victors hardness and the hardness of silicone carbide of SiC is 714.1 in Victors hardness. The surface hardness of a heat-treated stainless steel is 25% high compared with that of a ceramic material of SiC. The contact modes of rubbing surfaces are a dry friction, a water film friction and a mixed friction that is contaminated by a dust, silt, and moistures, etc. These two factors of a contact rubbing modes and a material property are very important parameters on the tribological performance such as a friction and wear between a seal ring and a seal seat in primary sealing unit. The experimental result shows that the surface hardness of a seal material is very important on the friction coefficient and a wear volume. Thus, the results recommend higher hardness of a seal material, which may reduce a friction loss and increase a wear life of primary seal components.

아크 금속 용사 표면 처리 방법에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가 (Evaluation of physical properties of Zn-Al metal coating according to arc metal spray surface treatment method)

  • 장종민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2022
  • Arc metal spraying is a widely used method for improving the performance of construction structures such as corrosion resistance and electromagnetic wave shielding. However, when arc metal spraying is applied to a concrete structure, adhesion performance may deteriorate. Therefore, the effect of each surface treatment method on the physical properties between the arc metal spray coating and concrete was reviewed by evaluating the deposition efficiency and adhesion performance according to the arc metal spray surface treatment method (surface reinforcing agent, roughening agent, and sealing agent). As a result, it is suggested as an optimal surface treatment condition to induce non-interface failure by using a roughening agent and to improve the properties of concrete and metal coatings by applying a surface reinforcing agent and sealing agent.

  • PDF

유전자알고리즘을 이용한 임플란트용 실링어버트먼트의 홈 깊이 최적화에 관한 연구 (Optimization of the Groove Depth of a Sealing-type Abutment for Implant Using a Genetic Algorithm)

  • 이현열;홍대선
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.24-30
    • /
    • 2018
  • Dental implants are currently widely used as artificial teeth due to their good chewing performance and long life cycle. A dental implant consists of an abutment as the upper part and a fixture as the lower part. When chewing forces are repeatedly applied to a dental implant, gap at the interface surface between the abutment and the fixture is often occurred, and results in some deteriorations such as loosening of fastening screw, dental retraction and fixture fracture. To cope with such problems, a sealing-type abutment having a number of grooves along the conical-surface circumference was previously developed, and shows better sealing performance than the conventional one. This study carries out optimization of the groove shape by genetic algorithm(GA) as well as structural analysis in consideration of external chewing force and pretension between the abutment and the fixture. The overall optimization system consists of two subsystems; the one is the genetic algorithm with MATLAB, and the other is the structural analysis with ANSYS. Two subsystems transmit and receive the relevant data with each other throughout the optimization processes. The optimization result is then compared with that of the conventional one with respect to the contact pressure and the maximum stress. The result shows that the optimized model gives better sealing performance than the conventional sealing abutment.

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF