• 제목/요약/키워드: Sealing

검색결과 1,300건 처리시간 0.029초

Wax-Sealing용 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of Current Fed High Frequency Resonant Inverter for Wax-Sealing)

  • 김동희;원재선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.568-574
    • /
    • 2001
  • This paper describes a current fed high frequency resonant inverter can be used as the power supply for wax-sealing. This circuit configuration is composed of conventional two unit inverter of single ended current find type in parallel. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has merits not only reduction of switch current distribution but also extension of load range in comparison with the conventional single-ended current fed high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. On the basis of characteristic values, a method of the circuit design is presented. Also, the theoretical analysis is proved through experiment and this proposed circuit shows that it can be practically used as the power supply system for wax-sealing and DC-DC converter.

  • PDF

시일과 코팅된 스틸면 사이의 구형 입자에 의한 접촉해석 (Contact Analysis Between Rubber Seal, a Spherical Particle and Coated Steel Surface)

  • 박태조;조현동
    • Tribology and Lubricants
    • /
    • 제25권4호
    • /
    • pp.225-230
    • /
    • 2009
  • Seals are very useful machine components in protection of leakage of lubricant or working fluid, and incoming of debris from outside. Various elastomer are widely used as sealing materials and the shaft surfaces are generally coated with high hardness material after heat treatment. It is generally known that the foreign debris and wear particles get stuck into sealing surface, the steel shaft surface can be damaged and worn by mainly abrasive wear. In this paper, using MARC, contact analysis are conducted to show the hard coated steel shaft surface can be fatigue failed by very small elastic particle intervened between seal and steel surface. Variations of contact and von-Mises stress distributions and contact half-widths with interference and coating thickness are presented. The maximum von-Mises stress occurs always in the coating layer or between coated layer/substrate interface. Therefore the coated sealing surface can be fatigued and then failed by very small particles. The results can be used in design of sealing surface and further studies are required.

유한요소해석을 이용한 더스트 씰 밀봉성에 대한 설계변수의 영향평가 (Estimation on the effect of design variables for sealing performance of the dust seal using finite element simulation)

  • 이광오;이상욱;허영민;강성수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.123-124
    • /
    • 2006
  • Usually, hydraulic cylinder is widely used as the actuator in the equipment of construction machines, airplane and military machines. In case of these devices, due to use under severe environment such as water, $SiO^2$ and dust, etc. seal which has high packing ability and long service life has been required. These characteristics are largely influenced by material and geometries of seal such as approach angle, withdrawal angle and interference. Recently, many a study about seal material has been performed so that many materials have been developed. But the concrete studies including the relationships between geometry of seal and sealing performance have hardly been performed yet. Therefore, in this study, we predicted the deformation behavior and contact normal distribution of dust seal with the variation of geometries of seal lip using finite element analysis. And based on the results of analyses, we discussed the effects of the design variables fur sealing performance of the dust seal.

  • PDF

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

알루미늄의 아노다이징과 나노 다이아몬드 분말 봉공처리에 의한 내식성과 내마모성 향상에 관한 연구 (Study on Improvement of Corrosion Resistance and Wear Resistance by Anodizing and Sealing Treatment with Nano-diamond Powder on aluminum)

  • 강수영;이대원
    • 한국표면공학회지
    • /
    • 제47권3호
    • /
    • pp.121-127
    • /
    • 2014
  • In this study, in order to improve corrosion resistance and wear resistance of aluminum, surface treatment was made by anodizing with oxalic acid solution and sealing with nano-diamond powder. Average size of nano-diamond powder was 30nm. Anodizing with oxalic acid made many pores in the aluminum oxide layer. Pore size and oxide thickness were investigated by scanning electron microscope (SEM). Pore size increased as temperature increased and voltage increased. It was possible to make oxide layer with pore diameter more than 50 nm. Oxide thickness increased as temperature and voltage and treatment time increased. Oxide layer with above $10{\mu}m$ thickness was made. Aluminum oxide layer with many pores was sealed by water with nano-diamond powder. Surface morphology was investigated by SEM. After sealing treatment with nano-diamond powder, corrosion resistance, wear resistance and hardness increased.

Characterization of Triode-type CNT-FED Fabricated using Photo-sensitive CNT Paste

  • Kwon, Sang-Jik;Chung, Hak-June;Lee, Sang-Heon;Choi, Hyung-Wook;Shin, Young-Hwa;Lee, Dal-Ho;Lee, Jong-Duk
    • Journal of Information Display
    • /
    • 제5권4호
    • /
    • pp.18-22
    • /
    • 2004
  • A carbon nanotube field emission display (CNT FED) panel with a 2 inch diagonal size was fabricated through screen printing of a prepared photo-sensitive CNT paste and vacuum in-line sealing technology. After surface treatment of the patterned CNT, only the carbon nanotube tips are uniformly exposed on the surface. The diameter of the exposed CNTs are usually about 20nm. The sealing temperature of the panel is around 390 $^{\circ}C$ and the vacuum level is obtained with $1.4{\times}10^{-5}$torr at the sealing. The field emission properties of the diode type CNT FED panel are characterized. Currently, we are in the process of developing a triode type CNT FED with a self-aligned gate-emitter structure.

FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석 (Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV)

  • 이정민;정화정;전문수;이형욱
    • 소성∙가공
    • /
    • 제27권1호
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

McSpadden Technique의 근관폐쇄효과에 대한 실험적 연구 (A STUDY ON THE SEALING ABILITY OF McSpadden TECHNIQUE)

  • 이상탁;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.127-134
    • /
    • 1984
  • This study was conducted to evaluate the sealing ability of McSpadden technique compared with lateral condensation and Engine reamer technique, and according to the degree of canal enlargement and the use and nonuse of sealer. Seventy single-rooted teeth were divided into 14 groups and each tooth was enlarged and obturated according to the purpose of this study. Obturated teeth were infiltrated by Indian ink and decalcified and cleared. The apical sealing ability was evaluated by measuring the degree of ink penetration into the canal. The results were as follows: 1. All the teeth filled by lateral condensation using gutta-percha cone and sealer proved better in canal sealing ability than McSpadden technique and Engine reamer technique, showing less ink penetration. 2. In the McSpadden technique, there was less ink penetration detected in using the sealer than not. 3. In all of the experimental methods, the difference of the degree of ink penetration according the degree of canal enlargement could not be accepted. 4. There was no significant difference in ink penetration degree between Engine reamer technique using sealer and McSpadden technique without sealer.

  • PDF

Leakage-free Rotating Seal Systems with Magnetic Nanofluids and Magnetic Composite Fluids Designed for Various Applications

  • Borbath, Tunde;Bica, Doina;Potencz, Iosif;Borbath, Istvan;Boros, Tibor;Vekas, Ladislau
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.67-75
    • /
    • 2011
  • Recent results are presented concerning the development of magnetofluidic leakage-free rotating seals for vacuum and high pressure gases, evidencing significant advantages compared to mechanical seals. The micro-pilot scale production of various types of magnetizable sealing fluids is shortly reviewed, in particular the main steps of the chemical synthesis of magnetic nanofluids and magnetic composite fluids with light hydrocarbon, mineral oil and synthetic oil carrier liquids. Design concepts and some constructive details of the magnetofluidic seals are discussed in order to obtain high sealing capacity. Different types of magnetofluidic sealing systems and applications are reviewed. Testing procedures and equipment are presented, as well as the sealing capabilities of different types of magnetizable fluids.

PDP 효율 및 생산성 향상을 위한 공정단순화 기술 (Process TAC Time Reduction Technology for Improving the Efficiency and Throughput of the PDP)

  • 권상직
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.45-50
    • /
    • 2013
  • This paper focuses on the fundamental issues for improving the efficiency and throughput of the AC PDP (Plasma Display Panel) manufacturing. The properties of the MgO protective layer affect the PDP efficiency. Especially, the secondary electron emission efficiency was affected on the deposition rate of MgO during the evaporation. In this study, the deposition rate of 5 $\AA$/s has given the maximum efficiency value of 0.05 It is demonstrated that the impurity gases such as $H_2O$, $CO_2$, CO or $N_2$, and $O_2$ can be remained inside the PDP panel before sealing and the amount of the impurity gases decreased rapidly as the base vacuum level increased, especially near $10^{-5}$ torr. The fundamental solution in order to overcome these problems is the vacuum in-line sealing process from the MgO evaporation to the final sealing of the panel without breaking the vacuum. We have demonstrated this fundamental process technology and shown the feasibility. The firing voltage was reduced down to 285 V at the base vacuum value of $10^{-6}$ torr, whreras it was about 328 V at the base vacuum value of $10^{-3}$ torr.