• 제목/요약/키워드: Scrubber efficiency

검색결과 114건 처리시간 0.026초

Evaluation Method on Destruction and Removal Efficiency of Perfluorocompounds from Semiconductor and Display Manufacturing

  • Lee, Jee-Yon;Lee, Jin-Bok;Moon, Dong-Min;Souk, Jun-Hyung;Lee, Seung-Yeon;Kim, Jin-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1383-1388
    • /
    • 2007
  • Recently, the semiconductor and display industries have tried to reduce the emissions of perfluorocompounds (PFCs) from the globally environmental regulation. Total amount of PFC emission can be calculated from the flow rate and the partial pressures of PFCs. For the precise measurement of PFC emission amount, the mass flow controlled helium gas was continuously injected into the equipment of which scrubber efficiency is being measured. The partial pressures of PFCs and helium were accurately measured using a mass spectrometer in each sample extracted from inlet and outlet of the scrubber system. The flow rates are calculated from the partial pressures of helium and also, PFC destruction and removal efficiency (DRE) of the scrubber is calculated from the partial pressure of PFC and the flow rate. Under this method, the relative expanded uncertainties of the flow rate and the partial pressures of PFCs are ± 2% (k = 2) in case the concentrations of NF3 and SF6 are as low as 100 μmol/mol.

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

덕트형 세정집진기의 입자포집 특성실험 (An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber)

  • 유경훈;여국현;손승우;황광호;정진원;김윤신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

사료제조 공장의 발생악취 특성 및 약액세정탑을 이용한 악취저감효율 평가 (Characteristic of odor from feed manufactory and evaluation of odor reduction efficiency using chemical scrubber)

  • 임지영;전용빈;송승준;조영근;김진한
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.389-395
    • /
    • 2018
  • The odor substances generated in a feed manufactory operating for the commercialization of animal-vegetable materials were analyzed and the odor reduction efficiency by a chemical scrubber was evaluated. The major causative substances in the feed manufactory comprised about 45.4% of ketone compounds and about 13.3% of aldehyde compounds. On the other hand, the removal efficiencies of diacetyl and acetoin as ketone compounds were 77.3% and 78.1%, respectively, by a chemical scrubber. Additionally, the removal efficiencies of acetaldehyde, butyraldehyde, valeraldehyde, 2-furancarboxaldehyde, and nonanal were 86.0%, 78.9%, 67.4%, 52.8%, and 71.9%, respectively. These rates were higher than the odor generation substance contribution rate as a result of treating the exhaust gas generated from the feed manufactory by the chemical scrubber using 5% of C3. It was also found that xylene, methylcyclopentane, benzene, ethylbenzene, 1,3,5-trimethylbenzene, and decane were almost not removed.

실험계획법을 이용한 입구덕트 스프레이의 습식 세정 효율 변화효과 분석 연구 (Quantitative Analysis of the Impact of Inlet Duct Spray on Scrubbing Efficiency using Experimental Design)

  • 이민우;김현호;구준모
    • 한국분무공학회지
    • /
    • 제24권1호
    • /
    • pp.8-14
    • /
    • 2019
  • The purpose of this study is to develop a packing-free wet scrubber to prolong the maintenance interval compared with the conventional packed bed wet scrubbers with which frequent operation stops are unavoidable to clean the packing materials. The main- and interaction-effects were quantitatively analyzed by regression analysis for the measured ammonia scrubbing data from the experiments prepared by experimental design. The scrubbing efficiency of the newly developed wet scrubber was found to be over 95% under the condition of flue gas flow rate of 90CMM and liquid-to-gas ratio $2l/m^3$ for all considered trials of experimental design. The interaction effect between the inlet duct spray and the filter was found to be important, which controls the droplet growth due to the droplet collisions between the duct- and scrubbing tower-spray. The presented methodology to analyze the impacts of operational and design factors on the scrubber efficiency showed potential for applications to optimize the future flue gas abatement process in semiconductor plants.

주류공정 내 L-alanine·염 스크러버를 이용한 고농도 이산화탄소 저감 효율 평가 (Evaluation of high concentration carbon dioxide reduction efficiency using L-alanine·salt scrubber in Liquor factory)

  • 김흥래;이준형;박형준;박기태;박일건
    • 한국응용과학기술학회지
    • /
    • 제37권2호
    • /
    • pp.214-223
    • /
    • 2020
  • 본 연구는 L-alanine을 적용한 스크러버의 주류공장 내 CO2 제거효율, 모니터링 데이터 분석/평가 및 에너지 저감효율을 평가하였다. 스크러버의 평균 제거율은 90.45%로 10,000 ppm이상의 고농도 CO2가 유입됨에도 제거효율이 뛰어난 것을 확인하였다. 스크러버 작동 후 작업장 내 CO2는 2,000ppm 이하로 유지하여 약 74% 이상의 이산화탄소 저감 효율을 확인하였다. 또한 소비되는 전력량을 측정한 결과 스크러버 작동 후 230 kWh로 약 7.26%의 에너지가 절감되는 것으로 나타났다. 즉, 본 개발제품을 적용한 결과로 작업장 내 이산화탄소 농도를 외기유입 없이 낮은 농도로 유지함에 따라 근무자의 작업환경을 개선시킬 수 있었으며 에너지 소비량 또한 저감할 수 있었다. 그러므로 식품, 주류공장 내 고농도 CO2 제거 공정으로써 스크러버가 유용할 것으로 기대된다.

활성탄 사용에 따른 습식세정시설에서의 대기오염물질 제거효율 평가 (Removal Efficiencies Estimation of Air Pollutants at Wet Scrubber Using Activated Carbon)

  • 신찬기;권명희;전종주;신대윤
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.87-93
    • /
    • 2003
  • This study carried out to recommend adaptable technologies and countermeasures for performance improvement of Wet Scrubber(WS) in industrial waste incinerator. When not using the Activated Carbon(AC), the removal efficiency of dust and HCl is 73%, 92%. And particulate phase and gaseous phase dioxins removal efficiency was evaluated up to 31% and 12%. In this case, dioxins enrichment was not revealed in WS. When using the AC mixing with scrubbing water, the case of 1,000ppm, removal efficiency of particulate phase dioxins was about 51%, and gaseous phase dioxins was about 96%. The case of 2,000ppm, removal efficiency of particulate phase dioxins was about 55%, and gaseous phase dioxins was about 97%. And the case of 3,500ppm, the removal efficiency of particulate phase dioxins was about 35%, and gaseous phase dioxins was about 96% respectively. By this study, using the AC was more useful to remove the gaseous phase dioxins, and needed to use proper concentration of the AC, that in case of 3,500ppm, the particulate phase dioxins removal efficiency was more lower than other cases.

연료유 스크러버 노즐의 스월베인 구조변화에 따른 분무특성의 수치해석적 연구 (Study of spray characteristics according to the variation of swirl vane geometry for Fuel oil scrubber nozzles)

  • 김인철;이경우;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.203-203
    • /
    • 2012
  • The Recovery facility, the scrubber is a collection device that injects liquid into the gas with the suspended particles using a spray nozzle. The liquid used is generally water. For the development of the design technology of a high efficiency scrubber, the spray characteristics according to the variation of the scrubber nozzle swirl vane was studied.

  • PDF

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.