• 제목/요약/키워드: Screw-in force

검색결과 239건 처리시간 0.027초

임플란트 고정체와 지대주의 체결방식에 따른 스크류 풀림토크에 관한연구 (A Study on the Screw Loosening Torque According to the Type of Tightening the Implant Fixture and Abutment)

  • 박수철;김홍식;함성원
    • 대한치과기공학회지
    • /
    • 제35권3호
    • /
    • pp.201-207
    • /
    • 2013
  • Purpose: In this study, the loosening torque test was conducted with three implant products that are produced, approved and sold in Korea, which are manufactured in different fixture and abutment tightening methods (internal submerged type, internal morse taper type, and external type) to examine the loosening torque of the screw according to the method of tightening the implant fixture and abutment. Methods: In the loosening torque test, the three types of fixtures and abutments with different tightening methods were tightened by rotating them clockwise with a $30N{\cdot}cm$ force using a driver equipped with an electric torque meter. The results of the test are as follows. Results: The loosening torque values of the internal submerged type, internal morse taper type and external type implants were $24.10{\pm}0.742N{\cdot}cm$, $29.10{\pm}1.710N{\cdot}cm$, and $26.60{\times}1.636N{\cdot}cm$, respectively. Conclusion: The screw loosening torque values of the three fixture and abutment tightening methods were analyzed via Kruskal Wallis test layout, and they were significantly different (p<0.05).

임플란트 나사에 적용되는 생역학적 원리: 문헌고찰 (Biomechanical considerations for the screw of implant prosthesis: A literature review)

  • 임소민;김대곤;박찬진;차민상;조리라
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.61-68
    • /
    • 2010
  • 연구 목적: 임플란트 보철물의 유지 나사에 적용되는 전하중은 나사를 조임으로써 임플란트와 지대주 사이에 인장력이 발생하면서 나사가 신장되는 힘을 말한다. 이 연구는 전하중에 영향을 미치는 생역학적 요인들과 나사 풀림에 기여하는 다양한 요인에 대하여 문헌을 고찰하고자 하였다. 연구 재료 및 방법: 1981년부터 2009년까지 발표된 나사 풀림을 다룬 임상연구 중 설정한 기준에 합당한 문헌을 요약하여 나사 풀림의 빈도를 밝혔고 나사의 안정성과 전하중에 관한 생역학을 다룬 문헌을 조사하고 요약하였다. 또한, 본 교실에서 연구한 실험실적 결과도 포함시켰다. 결과 및 결론: 나사 풀림의 정도는 나사에 토크를 가하는 기술이 발달함에 따라 현저히 감소하고 있다. 그 외에도 나사의 재질, 마찰계수를 감소시키기 위한 피복 기술의 발달 및 나사산의 모양 등 전하중에 영향을 줄 수 있는 요인을 고찰하였다. 전하중이 일정 수준 이하로 떨어지게 되면 나사의 움직임이 발생하게 되는데 이는 장기적으로 축적되어 피로파절 및 응착 마모, 소성 변형 등을 유발하게 되므로 주의해야 한다. 최적의 전하중을 주기 위해서는 토크 렌치를 이용하고 환자의 재내원시 다시 토크를 가하는 방법 등이 추천된다.

베어링의 로브형상과 절삭력 모델링 (Bearing Lobe Profile and Cutting Force Modeling)

  • 윤문철;조현덕;김성근
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.343-349
    • /
    • 1998
  • A modeling of machined geometry and cutting force was proposed for the case of round shape machining, and the effects of internally machined profile are analyzed and its realiability was verified by the experiments of roundness tester, especially in boring operation in lathe. Also, harmonic cutting force model was proposed with the parameter of specific cutting force, chip width and chip thickness, and in this study, we can see that bored workpiece profile was also mapped into cutting force signal with this model. In general, we can calculated the theoretical lobe profile with arbitrary multilobe. But in real experiments, the most frequently measured numbers are 3 and 5 lobe profile in experiments. With this results, we can predict that these results may be applied to round shape machining such as drilling, boring, ball screw and internal grinding operation with the same method.

  • PDF

MANUFACTURE AND CHARACTERISTICS OF SNACK-TYPE PRODUCTS CONTAINING MEAT AND STARCH

  • Cho, Soo-Hyun
    • 한국축산식품학회:학술대회논문집
    • /
    • 한국축산식품학회 1997년도 제18차 정기총회 및 학술발표회
    • /
    • pp.19-39
    • /
    • 1997
  • Extrusion conditions were optimized for blends of ground lamb and starch using a single-screw extruder for the purpose of producing expanded snack-type products. A central composite rotatable response surface methodology(RSM) design was used with variation in feed moisture, process temperature, and screw speed. The three variables significantly affected one or more of the measured physical properties of extrudates. The optimum conditions for minimum shear force values were 26.5% feed moisture, $148^{\circ}C$ process temperature, and 134 rpm screw speed. Lean ground beef, chicken, goat, lamb or mutton was blended with corn starch, and extruded at the optimum condition established from RSM experiments. Physical/rheological properties were generally similar, water activity was low (<0.12) and total aerobic plate counts were <10 for all products. Extrudates containing chicken had the highest ratio of polyunsaturated fatty acids to saturated fatty acids, whereas those containing beef had the highest ratio of monounsaturated fatty acids to saturated fatty acids. Sensory data indicated that texture was acceptable and flavor characteristics were not different among the products.

  • PDF

새로운 방식의 나사형 인공디스크 고정체 해석 (Finite Element Analysis of a Newly Designed Screw Type Fixture for an Artificial Intervertebral Disc)

  • 임종완;양현익
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권1호
    • /
    • pp.56-66
    • /
    • 2010
  • The various total replacement artificial discs have developed because spinal fusion has shown a lesser mobility of an operated segment and an accelerated degeneration at adjacent discs. But almost artificial discs have not yet been reached on the substitute surgery of fusion because many problems such as those clinical success rates were not more than them of fusion have not solved. In this paper, vertically inserted assemble-screw fixture in vertebrae was proposed to improve the fixed capability of artificial disc. And also, to evaluate the design suitability of newly designed screw-type, including fixtures of commercial discs such as wedge and plate type, the 1/4 finite element model with a vertebra and various implanted fixtures were generated, and next, 3 bending motions such as flexion, bending and twisting under the moment of 10Nm and compression under the force of 1000N were considered, respectively and finally, FE analyses were performed. Results of three fixture types were compared, such as Range of Motion and maximal stress, and so on. For ROM, the screw type was average 58% less than the wedge type and was average 42% less than the plate type under all loading conditions. For average stress ratio at closer nodes between vertebra and each fixture, the wedge type was the lowest as minimum 0.02 in twisting, screw types were the highest as maximum 0.28 in compression. As the results of using cement material, it was predicted that the instability problem of the wedge type was better solved. The screw type which could be increased by implanting depth according to the number of assembling mid screws, showed that the decreased tendency of ROMs and maximal cancellous bone stresses. In further study, controlling the number of assembling screws that was suitable for a patient's bone quality, development of surgical tools and keeping on design supplementations, which will be able to develop the competitive artificial disc.

초음파 진동선삭에서의 절삭 및 진동특성에 관한 연구 (A Study on the Cutting and Vibration Characteristic of Ultrasonic Vibration Cutting)

  • 이규배;임영호;이계철
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.147-154
    • /
    • 1994
  • In this study, ultransonic vibration cutting system was contructed by installing throw-away-tool tip (KT 350) by screw lock on the bending vibration mode in free-free beam. During the conventional cutting and ultransonic conventional cutting of SM45C, variations of cutting force, roughness and acceleration were measured. The results were compared and analyzed in detail, and it was found that the ultransonic vibration cutting was more effective in reducing cutting force compareed with the conventional cutting .

  • PDF

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구 (Detorque force and surface change of coated abutment screw after repeated closing and opening)

  • 장종석;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.500-510
    • /
    • 2008
  • 연구목적: 최근 지대주 나사에 WC/C 또는 TiN 코팅이 연구되고 있으며, 이들을 금속표면에 코팅 시 마찰계수의 감소와 부식에 대한 저항, 물리적 취약함의 해소 등의 효과를 얻을 수 있으며. 코팅된 지대주 나사에서 마모와 적합도, 풀림력이 향상되었다는 결과들이 보고되고 있다. 본 연구에서는 지대주 나사에 적용된 코팅이 나사 풀림에 미치는 영향을 알아보아 임상적으로 문제가 되고 있는 지대주 나사의 풀림현상을 해소하는데 그 목적이 있다. 연구재료 및 방법: 코팅되지 않은 타이타늄 지대주 나사와 (그룹 A) WC/C (그룹 B)와 TiN (그룹 C)으로 코팅된 지대주 나사의 10회 반복 착탈시 풀림력 및 표면의 변화를 비교해본 결과 다음과 같은 결론을 얻었다. 결과: 1. 반복 착탈 전, 그룹 A는 일정한 방향성을 가진 다소 거친 표면이 관찰되었으 나 그룹 B와 그룹 C는 코팅된 입자들이 관찰되었으며 코팅층이 전체적으로 균일하고 매끈한 모양을 나타내었다. 2. 반복 착탈 전, 그룹 B에 비해 그룹 C의 표면에서 코팅 입자의 크기가 더 크고 두껍게 코팅 된 모양을 나타내었다. 3. 반복 착탈 후, 그룹 A와 그룹 B에서는 지대주 나사 표면의 마모와 변형이 관찰 되었으며 그룹 B에서는 코팅 입자의 탈락 현상을 볼 수 있었다. 4. 반복 착탈 전과 후의 지대주 나사 무게의 변화를 측정한 결과 그룹 A가 가장 큰 감소를 보였으며, 그룹 C가 그룹 B 보다 무게의 변화가 적었으나 두 그룹간 통계적으로 유의한 차이는 없었다. 5. 그룹 B와 그룹 C는 그룹 A에 비해 높은 평균 풀림력을 나타내었고 통계학적으로 유의할 만한 차이가 있었다. 6. 그룹 A에서 그룹B 와 그룹 C보다 평균 풀림력의 감소 경향이 더욱 현저 하게 나타났다. 결론: 결론적으로, WC/C 또는 TiN 코팅된 지대주 나사는 반복적인 사용 후에도 코팅되지 않은 타이타늄 지대주 나사에 비해 뚜렷한 표면 변화를 보이지 않았으며 마모에 대한 저항성이 우수하였고 높은 풀림력을 나타내었다. 따라서 지대주 나사에 WC/C 또는 TiN 코팅을 적용 시 나사 풀림의 문제점을 개선할 수 있을 것으로 사료된다.

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.

Precise contact force control of a flip chip mounting head system

  • Shim, Jaehong;Cho, Youngim;Oh, Yeontaek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.109.1-109
    • /
    • 2002
  • This paper presents a macro/micro flip chip mounting head system for precise force control. In the proposed macro/ micro system, the macro actuator is conventional do servomotor with a ball screw mechanism and the micro actuator is a voice coil motor(VCM) that consists of four NdFeB magnets and a winded moving coil. For force control, a sensitive strain-gauge force sensor is mounted in the micro actuator. Through harmonic motion between macro and micro actuator, we would like to get precise contact force control when small sized flip chip is mounted on flexible substrate in high speed. In order to show the effectiveness of the proposed macro/micro flip chip mounting head system, we com...

  • PDF