• Title/Summary/Keyword: Screw type

Search Result 548, Processing Time 0.031 seconds

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Implant treatment on anterior cross-bite of a patient who had orthognathic surgery 20 years ago (20년전 악교정수술을 받았던 환자의 심한 전치부 반대교합의 해결을 위한 임플란트 치료 증례)

  • Park, Kwang Man;Leesungbok, Richard;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.245-253
    • /
    • 2019
  • Orthognathic surgery of skeletal Class III malocclusion improves oral function and facial appearance. The greater amount of skeletal discrepancy, the greater amount of teeth movement required for decompensation, and this often causes pathological changes in periodontal tissue especially in lower anterior dentition. We made a Top-Down treatment plan with personalized analysis using Face Hunter, Plane System and ARCUS Digma II, in order to resolve severe mobility and cross-bite of lower anterior teeth for 49-year-old female patient who had undergone orthognathic surgery 20 years ago due to skeletal Class III malocclusion and mandibular prognathism. Lower anterior teeth were extracted and alveoloplasty was done. After healing of the wound, immediate loading was conducted immediately after implant placement. Final restorations were fabricated Zirconia using CAD/CAM, and inserted intraorally screw-retained type. During 6-month follow-up, no abnormal episodes of restorations were observed, and obtained satisfactorily both of functional and esthetic outcomes.

Disassembly of the Package/PCB on Wasted LED Light and their Characterizations (LED 조명 모듈에 장착된 패키지/PCB의 분리 및 특성)

  • Seunghyun Kim;Ha Bich Trinh;Taehun Son;Jaeryeong Lee
    • Resources Recycling
    • /
    • v.32 no.6
    • /
    • pp.3-9
    • /
    • 2023
  • Separation of LED packages from PCBs and analysis of the adhesive components was conducted to enhance the recycling potential of LED modules. LED package was separated from PCBs using heat treatment under optimal conditions: temperature of above 250 ℃ and time of 20 minutes. The separation equipment can be established using a hot air injector with controlling the rotational speed of the internal screw. The separation efficiency of each type of substrate (aluminum and glass fiber) was investigated with the thickness range of the adhesive materials (0.25-0.30 and 0.30-0.35 mm). Under the optimal conditions, the efficiency can reach to 97.5% for both types of substrates with adhesive materials of thickness 0.25~0.30mm. Characterization of the residual adhesive substances from the separated LED package and PCB using microwave digestion and ICP analysis showed that the residue contained of 95% of Sn, less than 5% of Cu and Ag.

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Characteristics of Pelletized Swine Manure Compost (돈분뇨 퇴비의 펠렛가공 효과)

  • Jeong, K.H.;Kim, J.H.;Choi, D.Y.;Park, C.H.;Kwag, J.H.;Yoo, Y.H.;Han, M.S.;Jeong, M.S.;Won, H.H.;Yoon, T.Y.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.201-210
    • /
    • 2008
  • Farmers directly spread the livestock manure compost on their arable land as an organic fertilizer. However, there are some difficult problems to solve. first, we are unsure of whether the livestock manure compost can meet the nutritional demand of plant. Second, application of the current powered livestock manure compost to crop land is very difficult work due to heavy weight of compost and its powdered shape. For this reason, this study was carried out to develope high quality pelletized livestock manure compost. In pelletizing process with composted manure, the optimal water content for pelletizing was around 30$\sim$40%. When rice bran was mixed with 5% as a bonding agent on volume basis, the pelletizing effect was remarkably improved. On a dry matter basis, the contents of N and P of manure compost were 1.31%, and 0.58%, respectively. After pelletizing, the contents of compost pelleted were 1.37% and 0.54%, respectively. The same parameters of pelletized compost made by screw type Instrument were 1.37% and 0.53%, respectively. The other hand, N and P content of pelletized compost made by pellet mill type instrument were 1.06% and 0.18%, respectively.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Physicochemical Quality Characteristics of Traditional Kamju Using Extruded Rice Collet Powder (압출 쌀 콜렛 분말을 사용한 전통 감주의 제조 및 이화학적 품질 특성)

  • Je, Hae-Soo;Kang, Kyung-Hun;Park, Si-Young;Choi, Byeong-Dae;Kang, Young-Mi;Kim, Jeong-Gyun
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.147-152
    • /
    • 2016
  • This study was conducted to investigate the physicochemical quality properties and provide basic data for the activation of traditional Kamju of juice type product prepared by mixing malt and extruded rice collet powder. Malt extracts were prepared by extracting the mixture of malt and water at a weight ratio of 25:75 after soaking for 2 h at $45^{\circ}C$. Rice collet powder was prepared by adjusting the barrel temperature to $95^{\circ}C$, screw speed to $3.07{\times}g$, discharge port diameter to 7 mm and a raw material input to 50 kg/h, the powder was then ground to a particle size of 80 mesh. The physicochemical characteristics (pH, color, viscosity, reducing sugars, number of viable cells, free amino acids) and sensory evaluations were conducted at various time points during the saccharification and at different mixing ratios of the extruded rice collet powder to malt extract (5:95, 15:85, 25:75, 35:65, each at $55^{\circ}C$ for 9 h). As a result, with an increase in the proportion of the extruded rice collet powder and saccharification time, the physicochemical properties of traditional Kamju significantly improved (p<0.05). A mixing ratio of 35:65 rice collet powder to malt extract and a saccharification time of 9 h were found to be the most desirable conditions. However, based on the sensory evaluation, a mixing ratio of rice collet powder and malt extract of 25:75 and a saccharification time of 5 h resulted in the most preferable palatability of traditional Kamju (p<0.05). Therefore, the mixing ratio and saccharification time should be determined to provide a better choice with respect to the taste and economic aspects of traditional Kamju.