• Title/Summary/Keyword: Screw pullout

Search Result 23, Processing Time 0.033 seconds

A Study on Pullout Characteristics of Pedicle Screw Design Considering Anatomical Structure of the Lumbar Spine (척추의 해부학적 요소를 고려한 척추경 나사못 디자인의 Pullout 특성 연구)

  • Yoo, Kyeong-Joo;Park, Kwang-Min;Ahn, Kyoung-Gee;Ahn, Yoon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Recently, various types of pedicle screws have been developed considering the anatomical structure of the spine. The purpose of this study was to evaluate the pullout stiffness and strength of two types of commercial pedicle screws. The design of two type screws were single pitched thread (ST) pedicle screw and dual pitched thread (DT) pedicle screw, respectively. The tests were conducted in accordance with the ASTM standards using polyurethane (PU) test blocks which has anatomical structure of the spine. There was no significant difference in pullout stiffness between two types of screw. However, DT exhibited higher pullout strength than ST (p<0.05). Pedicle screw with dual pitched thread showed higher pullout strength without decrease in pullout stiffness compared to the standard pedicle screw. In conclusion, dual pitched thread design of the pedicle screw is considered to be more suitable than the single pitched thread for the anatomical structure of the spine.

Pullout Capacity of Screw Anchor Piles Using Field Pull-out Tests (현장인발시험을 통한 Screw Anchor Pile의 인발저항특성)

  • Yoo, Chung-Sik;Kim, Dae-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.1
    • /
    • pp.5-16
    • /
    • 2014
  • This paper presents the results of an investigation into the pullout characteristics of screw anchor pile using field pullout tests. A series of field pullout tests were performed on screw anchor piles with different geometric characteristics such as shaft and screw diameters. The results indicated that screw anchor piles exhibited significantly higher pullout capacities compared with the same diameter piles without screw. Also observed is that the set-up effect and the grouting significantly increase pullout capacities, although the magnitude of the increase depends on the ground condition. In addition the applicability of prediction methods for helical pile pullout capacity to screw anchor piles was also examined. The results are presented in such a way that the pullout characteristics of screw anchor piles with different installation conditions can be identified. Practical implications of the findings are discussed.

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

Mechanical Performance Comparison of Pedicle Screw Based on Design Parameters: Dual Lead and Dual Pitch (척추경 나사못의 디자인이 고정력 및 구동 토크에 미치는 영향 분석: 이중 나사 및 이중 피치 나사)

  • Choi, Sun-Gak;Cha, Eun-Jong;Kim, Kyung-Ah;Ahn, Yoon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.134-139
    • /
    • 2018
  • One of the most common problems with pedicle screw system is pullout of the screw. This study was performed to evaluate the pullout strength and driving torque of newly designed pedicle screws. The design of three type screws were standard pedicle screw, which had single lead threaded and single pitched design (Type A), single pitched and dual lead threaded pedicle screw (Type B), dual pitched and dual lead threaded pedicle screw (Type C), respectively. The tests were performed in accordance with the ASTM standards using polyurethane (PU) foam blocks. There was no significant difference in pullout strength among three types of screw. Type B and Type C exhibited higher insertion torque and removal torque than Type A, respectively (p<0.05). Pedicle screws newly developed with dual pitched and dual lead threaded design showed higher driving torque without decrease in pullout strength compared to the standard pedicle screw and could be inserted more rapidly with the same number of revolutions.

The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study (척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구)

  • Bak, Koang Hum;Ferrara, Lisa;Kim, Kwang Jin;Kim, Jae Min;Kim, Choong Hyun;Benzel, Edward C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

  • PDF

Experimental Evaluation of Pullout Strength of Long-Rawlplug Screw Anchor according to the Compressive Strength of Concrete and Embedded Length (콘크리트 압축강도 및 매입깊이에 따른 긴 칼블럭앵커의 뽑힘강도 평가)

  • Park, Jun-Ryeol;Yang, Keun-Hyeok;Kim, Sang-Hee;Oh, Na-Kyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.84-89
    • /
    • 2021
  • In 2017, the Gyeongju earthquake caused many casualties and considerable property damage by overturning and dropping blocks and bricks. Various reinforcement techniques were proposed, but some problems, such as short length or difficult construction, were encountered. Therefore, this study proposes a long-rawlplug screw anchor to improve the existing rawlplug anchor and conducts an experiment to evaluate the pullout strength. Variables in the pullout test were the compressive strength of concrete and the embedded length of the long-rawlplug screw anchor. According to the results, the pullout strength of the long-rawlplug screw anchor increased as the compressive strength of concrete increased, and they were not affected by the embedded length. Rather, it was found that the screw length of the long-rawlplug was important to the pullout strength.

Effect of Screw Geometries on Pull-out Characteristics of Screw Anchor Piles Using Reduced Scale Model Tests (스크류 제원이 스크류 앵커 파일의 인발저항 특성에 미치는 영향에 관한 축소모형실험)

  • Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.5-15
    • /
    • 2012
  • This paper presents the results of an investigation into the pull-out characteristics of screw anchor piles for use in braced excavation and cut-slope. A series of reduced-scale model tests were performed on model screw anchor piles with different geometric characteristics such as screw size and pitch length. The results indicated that the pullout resistance increases with decreasing the pitch length for a given screw size. It was also observed that the pullout capacity of a screw anchor pile increases with the screw size up to a certain size beyond which the increase becomes minimal. The results are presented in such a way that the pullout characteristics of screw piles with different screw geometric characteristics can be identified. Practical implications of the findings are discussed.

Clinical Effect of Transverse Process Hook with K-Means Clustering-Based Stratification of Computed Tomography Hounsfield Unit at Upper Instrumented Vertebra Level in Adult Spinal Deformity Patients

  • Jongwon, Cho;Seungjun, Ryu;Hyun-Jun, Jang;Jeong-Yoon, Park;Yoon, Ha;Sung-Uk, Kuh;Dong-Kyu, Chin;Keun-Su, Kim;Yong-Eun, Cho;Kyung-Hyun, Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.1
    • /
    • pp.44-52
    • /
    • 2023
  • Objective : This study aimed to investigate the efficacy of transverse process (TP) hook system at the upper instrumented vertebra (UIV) for preventing screw pullout in adult spinal deformity surgery using the pedicle Hounsfield unit (HU) stratification based on K-means clustering. Methods : We retrospectively reviewed 74 patients who underwent deformity correction surgery between 2011 and 2020 and were followed up for >12 months. Pre- and post-operative data were used to determine the incidence of screw pullout, UIV TP hook implementation, vertebral body HU, pedicle HU, and patient outcomes. Data was then statistically analyzed for assessment of efficacy and risk prediction using stratified HU at UIV level alongside the effect of the TP hook system. Results : The screw pullout rate was 36.4% (27/74). Perioperative radiographic parameters were not significantly different between the pullout and non-pullout groups. The vertebral body HU and pedicle HU were significantly lower in the pullout group. K-means clustering stratified the vertebral body HU ≥205.3, <137.2, and pedicle HU ≥243.43, <156.03. The pullout rate significantly decreases in patients receiving the hook system when the pedicle HU was from ≥156.03 to < 243.43 (p<0.05), but the difference was not statistically significant in the vertebra HU stratified groups and when pedicle HU was ≥243.43 or <156.03. The postoperative clinical outcomes improved significantly with the implementation of the hook system. Conclusion : The UIV hook provides better clinical outcomes and can be considered a preventative strategy for screw-pullout in the certain pedicle HU range.

Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density (반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석)

  • Jung, D.Y.;Lee, S.J.;Kim, D.S.;Shin, J.W.;Kim, W.J.;Suk, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

Experiment of single screw piles under inclined cyclic pulling loading

  • Dong, Tian Wen;Zheng, Ying Ren
    • Geomechanics and Engineering
    • /
    • v.8 no.6
    • /
    • pp.801-810
    • /
    • 2015
  • The ultimate pullout capacity under inclined dynamic loading is an important measure of the destruction degree of vertical screw piles (anchors) under dynamic actions. Based on the static and dynamic tests on two kinds of model screw piles, the ultimate bearing capacity was researched considering different distance-width ratio of blade (D/W) and preloading ratio. The results compared well with other experimental data available in the literature. This research reveals that D/W might determine the failure model of the piles (anchors), for example D/W = 3.14 or 5; a critical dynamic-static loading ratio (DSLR) existed in the experiments. The critical DSLR was reached under the conditions of 40%~60% preloading (D/W = 3.14) or 20%~40% preloading (D/W = 5), respectively.