• 제목/요약/키워드: Screw Loosening

검색결과 197건 처리시간 0.029초

추체간 유합술의 안정성에 관한 실험적 연구 (A Experimental Study on the Stability of Lumbar Interbody Fusion)

  • 김현수;박정호;김종필;이규열;이명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.526-529
    • /
    • 2005
  • The purpose of this study is to investigate a loosening process of screws through a fatigue test. Therefore, it is attempted to perform an interbody fusion on porsine lumbar spine using cage and screws. From the results, it is found that the combining force in both of the cylinder and the taper type screws located on the upper-left first start to decrease and then the combination between a rod and screw loosens. In addition, it is investigated that the life of taper type screw increases 5.5% and this fact is coincident with the previous results.

  • PDF

임플란트 지대주나사 코팅이 결합안정성에 미치는 영향 (Influence of the Dental Implant Abutment Screw Coating Materials on Joint Stability)

  • 임현필;박영선;방몽숙;양홍서;박상원;윤숙자
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.157-169
    • /
    • 2009
  • 본 논문의 목적은 코팅처리의 기계적 성질과 임플란트 지대주나사의 코팅처리가 고정체와의 결합안정성에 미치는 영향을 연구하고자 함이다. 이를 위해 Megagen 임플란트 시스템과 직경 15 mm, 높이 1 mm의 티타늄원판을 사용하였다. 지대주 나사와 원판에 TiN, TiCN, 및 TiC를 코팅하여 실험군으로, 코팅처리하지 않은 것을 대조군으로 하였다. 실험군은 지대주나사를 32 Ncm로 체결한 후 풀림회전력과 조임회전각을 측정하고, 10만 번씩 저작 모방 시험을 실시하여 풀림회전력의 변화를 관찰하였다. 조임회전각은 TiCN, TiC코팅나사에서 코팅하지 않은 나사보다 크게 나타났다(p<0.05). 그러나 풀림회전력은 TiCN, TiC코팅나사에서 코팅하지 않은 나사보다 낮게 나타났다(p<0.05). 저작 모방 시험후 코팅한 나사에서 코팅하지 않은 나사보다 풀림 회전력이 더 높게 나타났으며 풀림회전력은 건조상태와 습윤상태 사이에 유의한 차이가 없었다. 이상의 결과로 TiC 코팅군은 저작 모방 시험 전에는 풀림회전력이 낮았지만 저작 모방 시험 후에는 낮은 마찰계수로 인한 높은 풀림회전력과 조임회전각을 가져 임플란트 지대주나사의 결합안정성에 영향을 미치는 효율적인 방법임을 시사한다.

반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석 (Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density)

  • 정덕영;이성재;김동수;신정욱;김원중;석세일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE)

  • 황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력 (Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading)

  • 이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.151-155
    • /
    • 2017
  • 목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

풀림방지 로크너트의 구조해석 및 안전성 평가 (A Structural Analysis and Safety Evaluation of a Loose-proof Lock-Nut Structure)

  • 박상근
    • 융복합기술연구소 논문집
    • /
    • 제2권2호
    • /
    • pp.20-24
    • /
    • 2012
  • In this paper, we perform a ANSYS simulation of assembly structure composed of three parts, bolt, nut, and coil spring, under the loading of a screw torque 640~800 ($N{\cdot}m$) derived from the given bolt tensile strength 10.9, which allows us to investigate a lock-nut mechanism for the prevention of bolt-loosening after three parts are fastened. And also we investigate the safety factor of each component with effective stress distribution obtained from the simulation, which enables us to estimate the structural safety of a new lock-nut structure. Both simulation and investigation shown in this paper will contribute to the development of a new lock nut structure.

  • PDF

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

견봉 쇄골 관절 탈구에 대한 견봉 쇄골 관절의 관혈적 정복술 (Open Reduction of Acromioclavicular Joint for the Acromioclavicular Joint Dislocations)

  • 송현석;최남용;한석구;나기호;남원식;양혁재;박성진
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.189-195
    • /
    • 2006
  • Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.