• Title/Summary/Keyword: Screening Glass

Search Result 29, Processing Time 0.031 seconds

Agglomeration of Toner Particles with Fatty Alcohol and Their Removal by Screening (고급알코올을 이용한 토너의 응집 및 스크리닝을 통한 제거 효과)

  • 허용성;이학래
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.2
    • /
    • pp.24-32
    • /
    • 2004
  • Toner used in xerographic printing process is hydrophobic powder with low surface energy. The toner ink film fused on paper surface can be efficiently detached from a fiber surface during pulping, but it does not fragment again into fine toner particles. Ink agglomerates that result have too large particle size to be deinked by flotation. The purpose of this study is to enhance toner agglomeration using 1-octadecanol for improving the toner removal by screening. The effect of pH, pulping temperature, and 1-octadecanol on toner agglomeration and removal by screening was investigated using image analysis methods. Results showed that the size of toner agglomerates increased substantially when pulping was carried out at high temperature under acidic condition. When toner agglomerates showed spherical shape, the particle removal efficiency of screening was improved.

Surface Modification of Glass Chip for Peptide Microarray (펩타이드 Microarray를 위한 유리 칩의 표면 개질)

  • Cho, Hyung-Min;Lim, Chang-Hwan;Neff, Silke;Jungbauer, Alois;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.260-264
    • /
    • 2007
  • Peptides are frequently studied as candidates for new drug development. Recently, synthesized peptide library is screened for a certain functionality on a microarray biochip format. In this study, in order to replace the conventional cellulose membrane with glass for a microarray chip substrate for peptide library screening, we modified the glass surface from amines to thiols and covalently immobilized the peptides. Using trypsin-FITC (fluorescein isothiocyanate) conjugate that could specifically bind to a trypsin binding domain consisting of a 7-amino acid peptide, we checked the degree of surface modification. Because of the relatively lower hydrophilicity and reduced surface roughness, the conjugation reaction to the glass required a longer reaction time and a higher temperature. It took approximately 12 hr for the reaction to be completed. From the fluorescence signal intensity, we could differentiate between the target and the control peptides. This difference was confirmed by a separate experiment using QCM. Furthermore, a smaller volume and higher concentration of a spot showed a higher fluorescence intensity. These data would provide the basic conditions for the development of microarray peptide biochips.

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

Effects of National Dental Screening on Dental Caries Experience, Treatment, and Cost in Children (국가 구강검진이 어린이의 치아우식 경험, 치료 및 비용에 미치는 영향)

  • Lee, Jonghyung;Lee, Hangil;Son, Donghyun;Kim, Jihun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.248-256
    • /
    • 2020
  • This study aimed to evaluate the effects of national dental screening for children in Korea in the aspects of prevention of dental caries, the number of treatments related to dental caries, and cost of dental care. The study used the national cohort data on children health screening provided by National Health Insurance Service, and analyzed 32,937 1st dental screening, 22,608 2nd dental screening, 13,708 3rd dental screening, and 241,043 cases from the dental care of 27,944 children born in year 2008 and 2009. The decayed-filled teeth index and decayed-filled person rate, calculated from the results of the 2nd and 3rd dental screening, decreased as the number of preceding dental screening increased. Glass ionomer and amalgam restoration, pulp treatment of primary teeth and extraction of primary canine and molar were shown to decrease as the number of examined dental screening increased, and the total cost of dental care covered by national health insurance also decreased as the number of dental screening increased. In conclusion, national dental screening for children is an efficient and economical oral health care method that prevents dental caries and lowers the possibility of dental caries related treatment, thereby reducing cost of dental care.

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

Screening of spherical phosphors by electrophoretic deposition for full-color field emission display application

  • Kwon, Seung-Ho;Cho, sung-Hee;Yoo, Jae-Soo;Lee, Jong-Duk
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.79-84
    • /
    • 1999
  • the photolithographic patterning on an indium-tin oxide (ITO) glass and the electro-phoretic deposition were combined for preparing the screen of the full-color field emission display(FED). the patterns with a pixel of 400$\mu\textrm{m}$ on the ITO-glass were made by etching the ITO with well-prepared etchant consisting of HCL, H2O, and HNO3. Electrophoretic method was carried out in order to deposit each spherical red (R), green(G), and blue (B) phosphor on the patterned ITO-glass. The process parameters such as bias voltage, salt concentration, and deposition time were optimized to achieve clear boundaries. It was found that the etching process of ITO combined with electrophoretic method was cost-effective, provided distinct pattern, and even reduced process steps compared with conventional processes. The application of reverse bias to the dormant electrodes while depositing the phosphors on the stripe pattern was found to be very critical for preventing the cross-contamination of each phosphor in a pixel.

  • PDF

Surgical Extent for Ground Glass Nodules

  • Cho, Suk Ki
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.338-341
    • /
    • 2021
  • As diagnoses of small ground glass nodule (GGN)-type lung adenocarcinoma are increasing due to the increasing frequency of computed tomography (CT) screening, surgical treatment for GGN-type lung adenocarcinoma has rapidly become more common. However, the appropriate surgical extent for these lesions remains unclear; therefore, several retrospective studies have been published and prospectively randomized controlled trials are being undertaken. This article takes a closer look at each clinical study. Convincing evidence must be published on 2 issues for sublobar resection to be accepted as a standard surgical option for GGN lung adenocarcinoma. In the absence of such evidence, it is better to perform lobar resection as long as the patient has sufficient lung function. The first issue is the definition of a sufficient resection margin, and the second is whether lymph node metastasis is conclusively ruled out before surgery. An additional issue is the need for an accurate calculation of the total size and solid size on CT. Given the results of clinical studies so far, wedge resection or segmentectomy shows a good prognosis for GGNs with a total size of 2 cm or less. Therefore, sublobar resection will play a key role even in patients who can tolerate lobectomy.

Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure

  • Harima, Hirofumi;Hamabe, Kouichi;Hisano, Fusako;Matsuzaki, Yuko;Itoh, Tadahiko;Sanuki, Kazutoshi;Sakaida, Isao
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.596-599
    • /
    • 2018
  • An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

Percutaneous Electromagnetic Transthoracic Nodule Localization for Ground Glass Nodules

  • Song, Seung Hwan;Lee, Hyun Soo;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.494-499
    • /
    • 2021
  • Background: A recent increase in the incidental detection of ground glass nodules (GGNs) has created a need for improved diagnostic accuracy in screening for malignancies. However, surgical diagnosis remains challenging, especially via video-assisted thoracoscopic surgery (VATS). Herein, we present the efficacy of a novel electrical navigation system for perioperative percutaneous transthoracic nodule localization. Methods: Eighteen patients with GGNs who underwent electromagnetic navigated percutaneous transthoracic needle localization (ETTNL), followed by 1-stage diagnostic wedge resections via VATS between January and December 2020, were included in the analysis. Data on patient characteristics, nodules, procedures, and pathological diagnoses were collected and retrospectively reviewed. Results: Of the 18 nodules, 17 were successfully localized. Nine nodules were pure GGNs, and the remaining 9 were part-solid GGNs. The median nodule size was 9.0 mm (range, 4.0-20.0 mm); and the median depth from the visceral pleura was 5.2 mm (range, 0.0-14.4 mm). The median procedure time was 10 minutes (range, 7-20 minutes). The final pathologic results showed benign lesions in 3 cases and malignant lesions in 15 cases. Conclusion: Perioperative ETTNL appears to be an effective method for the localization of GGNs, providing guidance for a 1-stage VATS procedure.

Peripheral Eosinophilia and Clinico-radiological Characteristics among Health Screening Program Recipients

  • Park, Tae Yun;Jung, Jae-Woo;Jang, Ju Young;Choi, Jae Chol;Shin, Jong Wook;Park, In Won;Choi, Byoung Whui;Kim, Jae Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.2
    • /
    • pp.156-162
    • /
    • 2018
  • Background: Eosinophilia is well recognized in specific conditions. The objective of the present study was to determine clinico-radiologic characteristics of eosinophilia and changes in prevalence over 10 years in recipients of private health screening program at a tertiary hospital in Korea. Methods: Data of private health screening program recipients at the health promotion center of Chung-Ang University Hospital from 2004 to 2013 were collected. Health-related questionnaires and laboratory findings of private health screening program with possible relation with eosinophilia were reviewed. Results of enzyme-linked immunosorbent assay (ELISA) for parasite, chest computed tomography, and pulmonary function test were also reviewed. Results: The cumulative prevalence of eosinophilia was 4.0% (1,963 of 48,928). Prevalence of eosinophilia showed a decreased trend from 2004 to 2013. Most cases (96.6%) had mild degree of eosinophilia. Eosinophilic subjects were older and male-predominant. They showed lower levels of forced expiratory volume in 1 second ($FEV_1%$), forced vital capacity (FVC%), and $FEV_1/FVC$ than those without eosinophilia. Eosinophilic subjects showed higher positive rate for common parasite in ELISA than those without eosinophilia. On radiologic findings, consolidation and ground glass opacities were positively associated with the degree of eosinophilia. When eosinophil was classified based on severity, statistically significant correlation between the severity of eosinophil and radiologic abnormalities was found. Conclusion: Eosinophilia is uncommon in healthy population. It usually occurs at a mild degree. Eosinophilic patients have more radiologic abnormalities compared to those without eosinophilia. Such radiologic abnormalities are associated with the severity of eosinophilia.