• Title/Summary/Keyword: Screen Area Control

Search Result 59, Processing Time 0.026 seconds

A Study on the Displacements-Thermal Stress Analysis of Smoke/Heat Interception Screen in Eire Door (방화문용 연기/열 차단막의 변위-열응력 해석에 관한 연구)

  • 이동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.73-78
    • /
    • 2004
  • This study investigated about smoke/heat interception screen that can protect underneath of fire door and floor when occur fire, and keep out leakage or diffusion of smoke/heat. In this study, to considered differential pressure form smoke control area and mechanical force by fluid buoyancy of smoke when occur fire and stream of heat, are analyzed to used $ANSYS^{\circledR}$ of finite element analysis code. It presented direction of optimal design of smoke/heat interception screens that can minimize loading condition from study results, and helped that construct basic engineering data of smoke/heat interception systems as that utilize its shape design of smoke/heat interception screens.

Efficiency Analysis of Spiral Structured Twist Screen (식품분말 진동선별기 개선을 위한 구조물 효율 분석)

  • Park, In-soon;Na, En-soo;Jang, Dong-soon;Paek, Young-soo
    • Food Engineering Progress
    • /
    • v.14 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • In the food process, twist screen is widely used to divide particles on the basis of size. As screen equipped in the twist screen perfoms an important part in the particle size distribution mechanism, the contact area of screen and particles, retention time of particles on the screen, mesh and string thickness of screen and the flow pattern of particles on the screen are major points of the separation efficiency. To improve the separation efficiency, increase the retention time and control the flow pattern of particles, screen frame dam and spiral blockage are installed on the sieve of twist screen ${\emptyset}$ 1200 and ${\emptyset}$ 1500. Twist screen ${\emptyset}$ 1500 with frame dam treated similar separation capacity, 37% higher separation ratio and less non-separated particles of product output 1 than general twist screen. Twist screens with frame dam and spiral blockage showed less treatment capacity, three times higher division ratio and entire separation than general twist screen.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Efficient Spatial Index for Mobile Software (모바일 소프트웨어를 위한 효율적인 공간 인덱스)

  • Oh, Byoung-Woo
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.113-127
    • /
    • 2008
  • This paper proposes an efficient spatial index, named $AR^*$-tree(Area $R^*$-tree) which is a variant of the $R^*$-tree, for mobile software. A MBR(Minimum Bounding Rectangle) structure of the $AR^*$-tree has additional min and max values of area axis as well as x and y axes. The value of area axis is used to determine the significance of a spatial data. If area of a spatial data is large, then it is significant when drawing a map. To reduce complexity of a map on a small screen of mobile device, only significant spatial data can be found by the $AR^*$-tree. The result of a series of tests indicates that the $AR^*$-tree provides a method for control of readability of a map and guarantees an efficient performance at the same time.

  • PDF

A Duplex PCR Assay for Rapid Detection of Phytophthora nicotianae and Thielaviopsis basicola

  • Liu, Na;Jiang, Shijun;Feng, Songli;Shang, Wenyan;Xing, Guozhen;Qiu, Rui;Li, Chengjun;Li, Shujun;Zheng, Wenming
    • The Plant Pathology Journal
    • /
    • v.35 no.2
    • /
    • pp.172-177
    • /
    • 2019
  • A duplex PCR method was developed for simultaneous detection and identification of tobacco root rot pathogens Phytophthora nicotianae and Thielaviopsis basicola. The specific primers for P. nicotianae were developed based on its internal transcribed spacer (ITS) regions of ribosomal gene, ras gene and hgd gene, while the specific primers for T. basicola were designed based on its ITS regions and ${\beta}$-tubulin gene. The specificity of the primers was determined using isolates of P. nicotianae, T. basicola and control samples. The results showed that the target pathogens could be detected from diseased tobacco plants by a combination of the specific primers. The sensitivity limitation was $100fg/{\mu}l$ of pure genomic DNA of the pathogens. This new assay can be applied to screen out target pathogens rapidly and reliably in one PCR and will be an important tool for the identification and precise early prediction of these two destructive diseases of tobacco.

Evaluating Stability and Functionality of Hybrid Erosion Control Dam for Reducing Debris Flow Damage in Forested Catchment Nearby Urban Area (도시생활권의 토석류 피해 저감을 위한 복합형 사방댐의 안정성 및 기능성 평가)

  • Kim, Kidae;Kim, Dongyeob;Seo, Junpyo;Lee, Changwoo;Woo, Choongshik;Kang, Minjeng;Jeong, Sangseom;Lee, Dongkyun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.1
    • /
    • pp.59-70
    • /
    • 2018
  • The objective of this study was to develop erosion control dam for preventing disaster in consideration of characteristics of forested catchment near urban area, and to assess its stability and functionality to see its practicability in the field. Two types of hybrid erosion control dams were developed including debris flow prevention dam by using pillar and float board screen type and debris flow control dam by using groyne. Also, review about their static (sliding, overturning, bearing capacity) and dynamic (member force) stability was carried out. According to the result, most of the assessed items met standard safety level although there were some cases where assessed items were short of stability criteria against impact. Also, after miniature flume experiments based on the developed erosion control dam to prove structure function (material catch, deposit), it turned out the dam decreased flow sediment amount and velocity while increasing sediment-capturing capacity by 3.5 times on average compared to the one controlled without erosion control dam. When function of erosion control dam for forested catchment near urban area is quantified based on future flume experiments in a variety of conditions, the dams can be practically used in the urban area, contribution to effectively reducing debris flow damage.

Changes in the Emotion by the Expressive Definition of Visual Contents (영상콘텐츠의 표현밀도에 따른 감정의 변화)

  • Kim, Se-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.1
    • /
    • pp.192-201
    • /
    • 2010
  • This research deals with expressive definition of visual contents by using the distance between a subject and a screen resolution, and what changes affect the emotion of those looking at the expressive definition. A visual image captured from a HDTV screen was shown to the 61 students attending a university in the Busan area and SAM evaluation method was used to measure 3 different emotions such as pleasant, arousal, and dominance. While comparing different resolution, looking at high resolution contents rather than low resolution resulted in a direction of pleasant, arousal, and dominance. Also showing a different resolution than consistently showing the same resolution had a more volatile emotional effect. Aftermath multiple comparison resulted in a tendency for emotions to become unpleasant and un-arousal when high resolution contents were shown and then switched to a low resolution contents. There was no result of any significance in the control variables. Also on the aftermath multiple comparison on short, medium and long distance between the subject and the screen resolution, short distance had a bigger pleasant, arousal, and dominance emotional numbers than the rest. In a multiple variable verification result, a resolution and the distance of happiness and excitement showed a positive correlation.

Strategies on Text Screen Design Of The Electronic Textbook For Focused Attention Using Automatic Text Scroll (자동 스크롤 가능을 이용한 주의력 집중을 위한 웹기반 전자교과서 텍스트 화면 설계전략)

  • Kwon, Hyunggyu
    • The Journal of Korean Association of Computer Education
    • /
    • v.5 no.4
    • /
    • pp.134-145
    • /
    • 2002
  • The purpose of this study is to present the functional and technical solutions for text learning of web-based textbook in which each letter has its own focal point. The solutions help learners not to lose the main focus when eye moves to the next letter or line. The text screen of the electronic textbook automatically scrolls the text to up and down or left and right directions which are preassigned by learner. It doesn't need the operation of mouse or keyboard. And learner can change scroll speed and types anytime during scrolling. Automatic text scroll function is a solution for controlling data and screen to reflect the personal favor and ability. It contains the content structure of the text(characteristics, categorizations etc.), the appearance of the text(density, size, font etc.), scroll options(scroll, speed etc.), program control type(ram resident program etc.), and the application of the screen design principles(legibility etc.). To resolve these functional problems, technical 8 phases are provided, which are environment setting, scroll option setting, copy, data analysis, scroll coding, centered focus coding, left and right focus coding, implementation. The learner can focus on text without dispersion because the text focal points stay in the fixed area of screen. 1bey read the text following their preferences for fonts, sizes, line spacing and so on.

  • PDF

The Effect of Apraxia on Activity of Daily Living in Stroke Patients (뇌졸중 환자의 실행증이 일상생활에 미치는 영향)

  • Shin, Su-Jung
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.527-533
    • /
    • 2016
  • This study was conducted to investigate the apraxia affects activitys of daily living. 38 patients with stroke were participated and conducted to both Birminham Cognitive Screen(BCoS) apraxia test and K-MBI for ADL. Using a cutoff score of BCoS apraxia test, all patient was determine whether with apraxia or not and were distinguished by various types of apraxia. They were compared to the level of ADL using ANOVA. Apraxia patients 18, patients without apraxia is 20. The difference of ADL between the two groups was not. However, the result of classifying patients with apraxia subtypes, it showed a significant difference in grooming, eating, toileting, step, bowel control, and bladder control(F=4.431~9.193, p<0.05). As apraxia is cause of a negative effect on ADL, expert in the area to manage stroke patients should have to share information about whether apraxia is or not and make policy and treatment program considering the potential problem in ADL.

Analysis on Facilities & Basic Equipment of School Foodservice Safety in Pohang area (포항지역 학교급식의 안전성을 위한 학교 급식 조리실의 기본 시설.설비 조사)

  • Yun, Mi-Yeon;Lee, In-Suk
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.3
    • /
    • pp.264-276
    • /
    • 2006
  • The purpose of this study was to propose HACCP system implementation properly and to secure the food safety of school foodservices in Pohang city since the proper facilities and equipment should be key factors in food safety and production. So this study was designed to evaluate existing equipment in food production area, receiving and dining area, and employee facilities. Questionnaire was mailed to 107 school foodservice dietitians in Pohang area and 97 were responded (90.7% response rate). Approximately sixty percent of foodservices were not available separate receiving or polluted area, fifty one percent were installed screen door for insecticidal and temperature and humidity control, and these environmental conditions were hard to keep kitchen dry and sanitary condition. Usually public schools were better equipped than private schools. Forty three percent of school foodservice had initial use of non-foodservice, opened before 1994, and thirty three percent of elementary school foodservice. Among employee facilities, hand washing sanitation stand was prepared seventy nine percent (78.9%) of school foodservices. Dietitians chose outworn equipment and facilities (30.9%), difficulties of maintaining standard temperature and humidity for foodservice (20.6%), lacking separate receiving or polluted area (13.4%), indirect contamination of water hoss (10.3%), and lacking employee facilities (10.3%) as critical points to correct in school foodservice. Therefore governmental regulating agencies must review and approval of plans prior to new construction or extensive remodeling of school foodservice facilities. In addition to these requirement, plan must be set-up step by step to implement HACCP system properly.

  • PDF