무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가 (Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material)

  • 황영묵;조동현;이봉수;조효성;김신
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

Precise prediction of radiation interaction position in plastic rod scintillators using a fast and simple technique: Artificial neural network

  • Peyvandi, R. Gholipour;rad, S.Z. Islami
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1154-1159
    • /
    • 2018
  • Precise prediction of the radiation interaction position in scintillators plays an important role in medical and industrial imaging systems. In this research, the incident position of the gamma rays was predicted precisely in a plastic rod scintillator by using attenuation technique and multilayer perceptron (MLP) neural network, for the first time. Also, this procedure was performed using nonlinear regression (NLR) method. The experimental setup is comprised of a plastic rod scintillator (BC400) coupled with two PMTs at two sides, a $^{60}Co$ gamma source and two counters that record count rates. Using two proposed techniques (ANN and NLR), the radiation interaction position was predicted in a plastic rod scintillator with a mean relative error percentage less than 4.6% and 14.6%, respectively. The mean absolute error was measured less than 2.5 and 5.5. The correlation coefficient was calculated 0.998 and 0.984, respectively. Also, the ANN technique was confirmed by leave-one-out (LOO) method with 1% error. These results presented the superiority of the ANN method in comparison with NLR and the other methods. The technique and set up used are simpler and faster than other the previous position sensitive detectors. Thus, the time, cost and shielding and electronics requirements are minimized and optimized.

광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구 (Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide)

  • 이승재;조병두
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.671-677
    • /
    • 2023
  • 미세 섬광 픽셀을 사용하여 섬광체 블록을 구성할 경우 섬광체 블록 가장 자리에 위치한 섬광 픽셀들에서 중첩되어 영상화되는 결과가 나타난다. 이를 해결하기 위해서 섬광체 블록과 광센서 사이에 광가이드를 삽입하여 모든 섬광 픽셀들의 영상을 분리하여 획득하였다. 그러나 광가이드를 통해 빛의 손실이 발생할 수 있으며, 이는 에너지 분해능의 감소로 결국 영상의 질에 영향을 미치게 된다. 이에 본 연구에서는 광가이드의 옆면에 반사체를 사용하여 더욱 우수한 섬광 픽셀의 분리가 가능하며, 빛 손실을 최소화해 우수한 에너지 분해능을 확보할 수 있는 검출기를 설계하였다. 이전 연구와 비교 평가를 위해 빛 시뮬레이션이 가능한 DETECT2000을 통해 평면 영상을 획득하여, 분리 정도 및 빛 수집율을 평가하였다. 광가이드의 옆면에 반사체를 사용할 경우, 광가이드의 물질에 상관없이 모든 물질에서 매우 우수한 분리 정도를 나타내었으며, 이는 이전 연구에 비해 더욱 우수한 분리 결과를 나타내었다. 또한 빛 수집율은 반사체 적용하였을 경우, 그렇지 않은 경우에 비해 5배 이상 우수한 수집율을 보였다. 본 검출기를 소동물용 양정자방출단층 촬영기기에 적용할 경우 우수한 공간분해능 및 에너지 분해능을 통해 우수한 영상의 질을 확보할 수 있을 것이다.

고체형 검출기를 위한 핀 포토다이오드 제작 (Fabrication of PIN Photodiode for Solid-state Detector)

  • Kwak, Sung-Woo;Gyuseong Cho;Hyungjoo Shin;Park, Seung-Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.98-99
    • /
    • 2003
  • PIN photodiode has been used in solid-state detector for x-ray detection as a photosensor of visible light from scintillator. Since the light from CWO is short wavelength having peak at 490nm, the light is absorbed within a very shallow layer near the surface of the photodiode before arriving at the depletion layer and does not contribute to the signal. In designing the PIN photodiode, it is important to make the p-layer as shallow as possible. (omitted)

  • PDF

Characteristics of Radiation-Resistant Real-Time Neutron Monitor for Accelerator-Based BNCT

  • Nakamura, Takemi;Sakasai, Kaoru;Nakashima, Hiroshi;Takamiya, Koichi;Kumada, Hiroaki
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.105-109
    • /
    • 2016
  • Background: For an accelerator-based BNCT, we have fabricated a new detector consisting of quartz optical fibers that have excellent radiation-resistant characteristics. Materials and Methods: The developed detectors were irradiated at Kyoto University Research Reactor. Results and Discussion: The experimental results showed that the new detector had good output linearity for the neutron intensity, and the response of the new detector did not decrease during the irradiation. Conclusion: The new detector consisting of quartz optical fibers can be applied to measurement of neutron field of an accelerator-based BNCT.

구형의 섬광체를 이용한 방사선 스펙트로스코피 검출기 설계 및 방사선원 위치 추적 시스템 개발 (Design of a Radiation Spectroscopy Detector using a Spherical Scintillator and Development of a Radiation Source Position Tracking System)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.725-731
    • /
    • 2020
  • 구(sphere)형의 섬광체를 사용한 방사선 스펙트로스코피 검출기를 설계하였고, 여러 대의 검출기를 사용하여 방사선원의 위치를 추적하는 시스템을 개발하였다. 방사선원의 위치 추적은 방사선의 수는 거리의 역자승 법칙에 따라 감소하는 이론을 바탕으로 위치 추적 알고리듬을 설계하였으며, 여러 위치의 방사선원에서 발생된 방사선의 수를 측정하여 알고리듬을 통해 위치를 계산하였다. 방사선원에서 발생되는 방사선은 각 검출기에서 서로 다른 계수로 검출되며, 이러한 검출되는 계수의 차이는 거리의 역자승에 비례하여 달라진다. 설계한 방사선원 위치 추적 시스템의 성능을 검증 및 평가하기 위해 Geant4 Application for Tomographic Emission (GATE) 시뮬레이션을 실시하였으며, 서로 다른 위치에 놓이 방사선원에서 발생된 방사선을 각 검출기로 계수하였다. 측정된 방사선의 수는 방사선원 위치 추적 알고리듬을 통해 위치가 추적되었으며, 실제 방사선원의 위치와 알고리듬으로 계산된 위치와의 오차를 평가하였다. 실제 방사선원의 위치와 계산된 위치와의 오차는 평균 X축 0.11%, Y축 0.37%로 측정되었으며, 매우 정확하게 위치를 측정할 수 있음이 검증되었다.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

  • Ji, Young-Yong;Lim, Taehyung;Lee, Wanno
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.85-96
    • /
    • 2018
  • Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, $LaBr_3(Ce)$ scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an $LaBr_3(Ce)$ detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an $LaBr_3(Ce)$ detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

뮤온 입자를 활용한 지하매설물 탐사 가능성 분석 (Feasibility Analysis of Exploring Underground Utilities Using Muon)

  • 서승환;정문경;곽기석;강재모
    • 한국지반공학회논문집
    • /
    • 제38권11호
    • /
    • pp.137-147
    • /
    • 2022
  • 지하시설물의 정확한 매설위치를 파악하기 위해 다양한 지구물리탐사방법이 사용되고 있고, 정확도를 개선하기 위해 다수의 연구가 진행되고 있다. 본 연구에서는 우주선 뮤온이라는 입자를 활용하여 새로운 개념의 탐사 방법을 통해 지하매설물 탐사 가능성을 분석하였다. 신틸레이터(scintillator)와 광증배관(silicon photomultiplier)을 조합하여 소형 뮤온 검출기 시작품을 제작하고, 뮤온 입자 계수에 대한 보정 작업을 수행하였다. 시작품을 활용하여 모형 토조의 지반두께를 측정하였으며, 실측값과 약 3%의 오차로 실측값에 가까운 값을 추정할 수 있었다. 또한 뮤온 검출기를 지하매설물 탐사용으로 활용하기 위해 토모그래피 해석기술에 대한 이론적 기반을 분석하고, 천정각(zenith angle) 보정 방법을 제시하였다. 연구 결과 뮤온 입자에 의한 탐사는 밀도 그 자체를 고해상도로 해석하는 것이 가능한 기술로써 지하매설물 탐사를 위해 활용 가능할 것으로 판단된다.

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.