Analytical-numerical formula for estimating the characteristics of a cylindrical NaI(Tl) gamma-ray detector with a side-through hole

  • Thabet, Abouzeid A.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3795-3802
    • /
    • 2022
  • NaI(Tl) scintillation materials are considered to be one of many materials that are used exclusively for γ-ray detection and spectroscopy. The gamma-ray spectrometer is not an easy-to-use device, and the accuracy of the numerical values must be carefully checked based on the rules of the calibration technique. Therefore, accurate information about the detection system and its effectiveness is of greater importance. The purpose of this study is to estimate, using an analytical-numerical formula (ANF), the purely geometric solid angle, geometric efficiency, and total efficiency of a cylindrical NaI(Tl) γ-ray detector with a side-through hole. This type of detector is ideal for scanning fuel rods and pipelines, as well as for performing radio-immunoassays. The study included the calculation of the complex solid angle, in combination with the use of various points like gamma sources, located axially and non-axially inside the through detector side hole, which can be applied in a hypothetical method for calibrating the facility. An extended γ-ray energy range, the detector, source dimensions, "source-to-detector" geometry inside the side-through hole, path lengths of γ-quanta photons crossing the facility, besides the photon average path length inside the detector medium itself, were studied and considered. This study is very important for an expanded future article where the radioactive point source can be replaced by a volume source located inside the side-trough hole of the detector, or by a radioactive pipeline passing through the well. The results provide a good and useful approach to a new generation of detectors that can be used for low-level radiation that needs to be measured efficiently.

1 eV 이하 에너지 영역에서의 180Ta 동위원소의 중성자공명에 대한 연구 (A Study on Neutron Resonance Energy of 180Ta below 1eV Energy)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.287-292
    • /
    • 2014
  • 본 연구는 자연 속에 미량(존재비: 0.012 %)으로 존재하는 $^{180}Ta$의 중성자포획 공명에 대하여 포획단면적의 계산치와 측정치를 비교하여 분석하였다. 일반적으로 중성자 공명은 Breit-Wigner식으로 정의되며, 식에는 공명에너지를 중심으로 공명의 폭을 결정하는 다양한 인자들로 구성되어 있다. 그러나 $^{180}Ta$의 경우 중성자포획단면적과 공명에 대한 정보가 잘 알려져 있지 않고 실험적으로도 측정되어진 예가 현재까지는 없는 것이 현실이다. 따라서 본 실험에서는 천연 Ta속에 포함되어진 $^{180}Ta$에 의한 중성자 포획에 의해 발생되는 감마선을 관측하여 $^{180}Ta$의 공명을 분석하고 Mughabghab에 의해서 계산되어진 공명인자를 사용하여 1 eV이하의 에너지에 대한 중성자포획단면적을 계산하고 비교분석하였다. 측정을 위해서 교토대학원자로 실험소의 46-MeV 전자선형가속기를 이용하여 중성자 TOF 방법으로, 에너지 영역 0.003 eV에서 10 eV에 걸쳐 측정하였다. 측정을 위해서는 12개의 $Bi_4Ge_3O_{12}(BGO)$섬광체로 구성된 전에너지 흡수검출장치로 $^{180}Ta(n,{\gamma})^{181}Ta$ 반응으로부터 나오는 즉발감마선을 측정하였다.

양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구 (Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification)

  • 이한림;민철희;박종훈;김성훈;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.162-168
    • /
    • 2012
  • 양성자 치료에서 치료의 목표를 달성하고 환자의 안전을 제고하기 위해 인체 내 양성자 빔의 분포를 확인하는 것이 중요하다. 양성자 선량분포와 밀접한 관계가 있는 즉발감마선의 2차원 분포 측정을 위하여 본 연구팀에서는 다수의 CsI(Tl) 섬광체가 1차원 종형으로 배열된 검출기 배열과 집속장치 및 다채널 신호처리 장치로 이루어진 측정장치를 개발하고 있다. 이에 본 연구에서 몬테칼로 기반의 MCNPX 코드를 이용하여 최적화된 측정 장치를 설계하고자 하였다. 즉발감마선을 효과적으로 측정하기 위해 CsI(Tl) 섬광체의 크기를 $6{\times}6{\times}50mm^3$로 결정하였으며, 배경감마선의 영향을 최소화하고 빔의 진행방향에서 수직방향으로 발생하는 즉발감마선만 측정하기 위해 집속장치의 구멍 크기는 면적 $6{\times}6mm^2$, 길이 150 mm로 최적화되었다. 150 MeV 양성자 빔에 대한 성능 예측 전산모사연구를 수행한 결과, 본 연구에서 최적화된 측정 장치를 통해 즉발감마선 2차원 분포를 측정할 수 있었으며, 1 mm 오차범위에서 양성자 빔의 비정을 결정할 수 있었다. 이를 바탕으로 현재 다채널의 신호처리 장치를 개발하고 있으며 실제 양성자 빔을 이용한 즉발감마선 분포측정을 통해 측정 장치의 성능을 검증할 것이다.

진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성 (The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging)

  • 박지군;허예지;박정은;박상진;김현희;노시철;강상식
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.35-38
    • /
    • 2009
  • 최근 의료영상분야에서 형광체와 광도전체 물질을 이용한 디지털 평판형 X선 영상검출기가 폭넓게 이용되고 있다. 본 연구는 CsI:Na 형광체층과 광민감도가 우수한 비정질 셀레늄(a-Se)층의 이중 접합구조로 구성된 변환구조 설계를 위한 몬테카를로 시뮬레이션과 X선에 대한 광학적 및 전기적 반응특성을 조사하였다. 먼저 CsI:Na의 발광스펙트럼과 a-Se의 광흡수 스펙트럼을 측정하여 X선에 의한 신호 변환특성을 분석하였다. 또한, 인가전기장의 함수에 따른 X선 민감도을 측정하여 상용화된 a-Se($500{\mu}m$)의 직접변환 검출기와 비교 평가하였다. 측정결과로부터, $10V/{\mu}m$에서 CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) 변환센서의 X선 민감도는 $7.31nC/mR-cm^2$ 이고, a-Se($500{\mu}m$) 검출기는 $3.95nC/mR-cm^2$로 약 2배 정도 높은 값을 보였다.

  • PDF

중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구 (Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.403-408
    • /
    • 2012
  • 본 연구는 천연 인듐의 중성자폭획 후에 발생된 감마선을 12개의 BGO($Bi_4Ge_3O_{12}$) 섬광검출기로 구성된 검출장치를 이용하여 즉발감마선을 측정하여 중성자공명에 의해서 발생된 감마선을 분석하여 중성자의 에너지 1 ~ 300 eV 영역에 대하여 공명에너지를 분석하였다. 사용되어진 검출장치는 시료에서 발생된 즉발감마선에 대하여 모든 감마선을 측정할 수 있는 기하학적인 구조로 만들어졌다. 중성자원으로는 교토대학의 원자로연구소의 46-MeV 전자선형가속기의 광핵반응에서 발생하는 중성자를 이용하였다. 중성자발생원으로부터 검출기까지의 거리가 $12.7{\pm}0.02m$이므로 광핵반응에서 발생하는 강한 X선의 영향을 고려하여 수 keV영역이하의 중성자에너지에 대하여 중성자공명을 측정하였다. 측정되어진 공명들은 1 eV이상의 에너지 영역에서 거대 공명들을 측정하였고 이들 공명들은 이론에서 알려진 값들과 비교하였다. 본 연구를 통하여 기존에 알려진 거대 공명의 에너지를 확인하였고, 100 eV이상의 에너지 영역에서의 공명에너지들에 대한 평가에 의한 이론값들이 실제로 존재하는 공명임을 실험적으로 확인하였다. 1 keV 이상의 영역에 대하여는 공명이 연속적인 구조를 보이고 있음을 실험적으로 확인했으며 공명에 대하여 통계적인 평가가 있어야함을 알았다. 91.49 eV 공명은 본 연구를 통하여 처음 발견되어진 공명이라 볼 수 있다.

양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발 (Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification)

  • 이한림;박종훈;김재현;정원균;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제39권2호
    • /
    • pp.81-88
    • /
    • 2014
  • 최근, 인체 내 양성자 빔의 선량 분포를 검증하기 위해 새로운 개념의 영상기법인 감마 꼭지점 영상(gamma vertex imaging, GVI)이 제안되었다. GVI는 양성자 빔과 매질과의 핵반응으로 인해 발생하는 즉발감마선의 발생 위치를 결정하기 위해 입사한 감마선을 전자 변환기에서 전자로 변환한 후 전자의 궤적을 추적하는 방법을 사용한다. GVI 영상장치는 감마선을 전자로 변환하기 위한 전자 변환기, 전자 궤적을 추적하기 위한 2대의 양면 실리콘 스트립 검출기(double-sided silicon strip detector, DSSD)와 전자의 에너지 결정을 위한 섬광체 흡수부 검출기로 이루어진다. 본 연구에서는 GVI 영상 장치를 구성하는 DSSD 전용의 신호처리 장치를 구성하는 핵심 장치인 전하 민감형 전치증폭기(charge sensitive preamplifier, CSP) 모듈과 성형 증폭기 모듈을 개발하였으며, 상용 제품과 성능을 비교해 보았다. 감마선원의 에너지 스펙트럼 측정 결과, 자체제작 CSP 모듈이 상용 제품보다 에너지 분해능이 약간 낮은 것을 확인하였으며, 성형 증폭기의 경우 거의 동일한 성능을 보여주는 것을 확인할 수 있었다. 개발된 신호처리 장치의 노이즈의 크기를 나타내는 $V_{rms}$ 값은 6.48 keV으로 평가되었으며, 이는 145 ${\mu}m$의 DSSD에 전달되는 전자의 에너지( > ~51 keV)를 고려할 때 본 장치를 이용하여 전자의 궤적을 충분히 정확하게 결정할 수 있음을 확인할 수 있음을 보여준다.

PET/CT 장치의 uniformitly측정에 관한 연구 (A Study of Uniformity Test in PET/CT)

  • 김수근;정희일;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권1호
    • /
    • pp.13-19
    • /
    • 2006
  • PET scanner는 양전자의 소멸복사에 의한 511 Kev의 감마선을 검출한다. multi ring detector에서 선원과 검출기사이의 기하학적 위치에 따른 감마선 검출에 대한 균등성(uniformity)을 검토 분석하였다. 감마선원과 검출기의 배열위치에 따른 이론적 검토와 일정한 크기의 phantom 내에서 방출되는 감마선을 2차원적으로 preset count하고, 검출기의 위치에 따라 평균계수치에 대한 편차율의 분포를 통하여 그 균등성을 비교 분석하였다. 1 bed data를 얻을 수 있는 47개의 검출기군으로 분류하고, 각 검출기군의 위치에 따른 편차율을 비교분석한 결과, 산란선과 산란되지 않은 모든 방사선량의 분포가 많은 중심군인 3번째부터 45번째까지에서는 평균편차의 비율이 $0.1{\sim}0.7%$로 비교적 균등도가 높게 나타났으나, 주변부에서는 편차율의 분포가 $1.1{\sim}5.2%$의 차이를 나타내고 있어, 주변부에서의 균등성이 중심부보다 감소되었다. 이것은 검출기 위치에 따른 계수율의 차이에 대한 이론적 근거와 일치하고 있으며, 감도를 알기위한 계수측정 부분에서도 중심부와 주변부와의 차이가 크게 다르게 나타났다. 이와같은 불균등성을 감소시키기 위하여 선원으로부터 모든 검출기 유효시야(UFOV) 내에서 충분한 방사능이 검출될 수 있도록 하는 우선적 조치가 필요하다고 판단된다.

  • PDF

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정 (The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter)

  • 김진섭;김종범;김재호;이나영;정성희
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.13-20
    • /
    • 2008
  • 석유 및 정유관련 산업에서 다중상(multi-phase flow) 유체의 배관 내 흐름은 일반적인 현상의 하나이다. 그러나 각각의 상에 대한 정확한 유량측정은 항상 정확한 결과획득을 얻는데 장애의 근원으로 작용하였다. 일반 상업용 유량계는 일정 이상의 기포가 포함된 유체 흐름의 경우 유량계측에 상당한 오차를 유발한다. 본 연구에서는 ${\gamma}$-ray attenuation 기법을 이용하여 clamp-on 타입으로 배관 외부에서 다중상 유체흐름의 유량 측정을 수행하였다. 사용된 밀봉 감마선원으로는 $^{137}Cs$ 20 mCi와 17 mCi 두 개의 동위원소를 사용하였으며, 감마선 검출기로는 $2"{\times}2"$ NaI(Tl) 섬광계수관을 이용하였다. 방사선 검출기로부터 데이터를 수집하고 각각의 데이터에 대해 푸리에 변환과 필터링을 통해 노이즈를 최소화하였다. 복원된 신호에 대해 상호상관함수(cross correlation function)를 적용하여 두 검출기 사이의 통과시간(transit time)을 측정함으로써 유량을 산정하였다. 배관 내 기포함량 측정을 통해 유량을 보정해줌으로써 측정유량의 정확도를 높였다. 두 선원간의 거리가 4D(D; inner diameter) 그리고 본 실험의 측정조건(N/S: $0.12{\sim}0.15$, sampling time ${\Delta}\;t$: 4msec) 하에서 기포량(단면적 대비 $6.1\;%{\sim}9.2\;%$) 보정을 통해 산정된 유량은 계측오차가 실제 평균유량 대비 1.7 % 이하인 정확도를 보였다. 또한 두 밀봉 감마선원 간의 거리가 가까울수록 통과시간 측정에 정확도가 향상되므로 보다 정확한 유량측정이 가능하였다. 본 연구를 통해 다중상 혼합유체의 유량을 밀봉감마선원과 상호상관 기법으로 이용하여 계측할 수 있음을 확인하였다. 방사성동위원소의 선택 및 계측시스템의 최적화 조건 등에 대한 추가연구가 수행된다면 석유화학 산업과 같은 장치산업의 유지관리 측면에 경제적으로 크게 기여할 수 있을 것으로 판단된다.

감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가 (Development and Performance Test of Preamplifier and Amplifier for Gamma Probe)

  • 봉정균;김희중;이종두;권수일
    • 대한핵의학회지
    • /
    • 제33권1호
    • /
    • pp.100-109
    • /
    • 1999
  • 목적: 핵의학장비를 구성하는 신호처리단의 전단증 폭기와 주증폭기는 방사선의 에너지 정보를 주는 펄스를 분석하는데 중요한 부분이다. 이러한 신호처리부분들은 대부분 크기가 표준화된 상용의 Nuclear Instrument Module (NIM)을 사용한파. 그러나, NIM은 이동형 감마프로브에 사용하기에는 너무 부피가 커서 부적합한 편이다. 이를 위해 본 연구는 이동형 감마프로브에 적합한 소형화된 전단증폭기와 주증폭기를 자체 제작하여 성능평가를 하였다. 대상 및 방법: 본 연구에서 제작된 전단증폭기는 전하민감형 전단증폭기였으며, 주증폭기는 capacitor resistor-resistor capcitor (CR-RC) 회로를 이용하여 제작되었다. 제작 후 성능평가를 위해 $2"{\times}2"$ NaI(T1) 섬광체가 부착된 EP-047 (Bicron Saint-Gobain/Norton Industrial Ceramics Co., Ohio, U.S.A) 검출기와 $1"{\times}1"$ NaI(T1) 섬광체가 부착된 R1535 (Ha-mamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) 검출기를 다중채널분석기인 AccuSpec/A (Canberra Industries Inc., Meriden Conneticut, U.S.A)를 이용 에너지 스펙트럼을 얻었다. NIM은 TC 145 (Oxford Instruments Inc., Oak Ridge, U.S.A)와 TC241 (Oxford Instruments Inc., Oak Ridge, U.S.A)을 이용하였다. 에너지 스펙트럼은 37 kBq ($1{\mu}Ci$) Cs-137과 2.96 MBq ($80{\mu}Ci$) Tc-99m의 방사선원을 이용하여 250초씩 얻었다. 결과: 자체 제작한 진단증폭기와 주증폭기를 EP-047 검출기와 연결하여 얻은 Tc-99m (140 keV)과 Cs-137 (662 keV)의 에너지 분해능은 각각 12.92%, 5.01%이었으며, R1535 검출기를 연결하여 얻은 Tc-99m과 Cs-137의 에너지 분해능은 각각 13.75%, 5.19%이었다. 그리고 NIM을 EP-047 검출기와 연결하여 얻은 Tc-99m과 Cs-137의 에너지 분해능은 14.6%, 718%이었으나, R1535 검출기를 연결하여 얻은 Cs-137 에너지 스펙트럼은 광봉우리 위치가 변화되어 안정되지 못하였고, Tc-99m의 에너지 스펙트럼은 쉽게 얻을 수 없었다. 결론: 본 연구에서 자체 제작한 전단증폭기와 주증폭기는 광증배관의 종류에 관계없이 우수한 성능을 보여주었다. 결론적으로, 본 연구에서 제작한 전단증폭기와 주증폭기는 소형화된 계수용 감마프로브와 영상용 감마프로브에 활용하는데 유용할 것이라고 사료된다.