• Title/Summary/Keyword: Science room

Search Result 4,044, Processing Time 0.037 seconds

Heat and Flow Analysis on Cabin Room of Battle Tank (전차 포탑 승무원실의 내부 열/유동장에 관한 수치적 연구)

  • NamKoung, H.J.;Lee, K.H.;Park, B.H.;Roh, K.L.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.5-10
    • /
    • 2006
  • The heavy thermal load to battle tanks can cause electronic components' malfunction and crew to be put out of action. The thermal load is generated from Internal heat sources such as electronic devices installed in the room as well as extremely hot weather. In this study, heat and flow analysis for the cabin room of a battle tank was performed to deal with this thermal problem. This study presented the validation of simulation results in comparison with those of test, the investigation of optimal flow design for effective cooling in cabin room and finally the evaluation of thermal comforts to crew.

Analysis and Evaluation of Pathogen Contamination Status in Interventional Angiography Room (인터벤션실의 오염실태 분석 및 평가)

  • Kim, Kyung-Wan;Im, In-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.233-239
    • /
    • 2022
  • In the radiology department, where radiation is used in medical institutions to perform examinations with various equipment, the field of surgical treatment is the intervention angiography room. Accordingly, strict infection control is required. The purpose of this study was to determine the contamination status by detecting pathogens before and after disinfection in the intervention angiography room, and to determine the degree of death by using a disinfectant, sodium dichloride isocyanurate, which is mainly used in the intervention angiography room. The subjects were 10 medical institutions of general hospital level or higher with an intervention angiography room in the P city, and 12 places with high contact frequency during examinations and procedures were sampled and requested to an analysis institution. As for the sample collection method, up/down, left/right directions were used to increase precision. Before disinfection, all procedures were completed, and after disinfection, exposure was performed using a disinfectant for at least 10 minutes, and detection was performed using a transport medium. As a result, in the pathogen analysis, most pathogens were detected in a humid environment or in a place with high contact frequency for microorganisms to thrive. The detected pathogens were found in the general environment or were human flora. It is a pathogen that does not cause disease under normal healthy host conditions. However, it was found to be an opportunistic infection that causes opportunistic infection depending on the case or situation in which the body's resistance is weakened. In addition, as a result of using the disinfectant mainly used in the intervention angiography room, it was found that more than 93.3% of them died. Therefore, the data of this study will be used as good basic data for the evaluation of pathogens in the intervention angiography room and will be of great help in infection control.

Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation (고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화)

  • Lee, Jin-kook;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.171-180
    • /
    • 2016
  • This study was to evaluate the change in characteristics of concentration of ozone after exposure to high energy radiation in linac room. Background ozone concentration of linac room was measured and compared to ozone concentration around linac room. Background ozone concentration of linac room was mean $17.4{\pm}7.9ppb$. It was 50% of the ozone concentration($36.8{\pm}22.3ppb$) around linac room(p<0.05). The concentration of ozone after exposure to high energy radiation in linac room was elevated to double of background ozone level, intensity after exposure. with exposure time concentration of ozone increased proportionally. It showed maximum level at 130~180seconds and slowed a tendency to saturate. It required more than 10 minutes for ozone concentration in linac room to drop to ozone concentration around linac room. The concentration of ozone after exposure to high energy radiation is high enough to cause specific physical symptoms, such as acute dyspnea or chest pain due to dry cough. Exposure to high concentration of ozone in sealed linac room can aggravate pulmonary disease, so special attention is needed.

Study on the Room Temperature Degreasing Conditions of Steel Sheet for Electrogalvanizing (전기아연도금용 강판의 상온 탈지 조건 연구)

  • Tae-Yeon Park;Chae-Won Kim;Su-Mi Yang;Hee-Jun Hong;In-Chul Choi
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.1
    • /
    • pp.16-22
    • /
    • 2024
  • The conventional degreasing process involves removing oil and contaminants at temperatures above 80℃, resulting in excessive energy consumption, increased process costs, and environmental issues. In this study, we aimed to find the optimal degreasing conditions for the pre-treatment process of electro-galvanizing cold-rolled steel sheets, conducted efficiently at room temperature without the need for a separate heating device. To achieve this, we developed a room temperature degreasing solution and a brush-type degreasing tool, aiming to reduce energy consumption and normalize the decrease in degreasing efficiency caused by temperature reduction. Alkaline degreasing solution were prepared using KOH, SiO2, NaOH, Na2CO3, and Sodium Lauryl Sulfate, with KOH and NaOH as the main components. To enhance the degreasing performance at room temperature, we manufactured additives including sodium oleate, sodium stearate, sodium palmitate, sodium lauryl sulfate, ammonium lauryl sulfate, silicone emulsion, and EDTA-Na. Room temperature additives were added to the alkaline degreasing solution in quantities ranging from 0.1 to 20 wt.%, and the uniformity of degreasing and the adhesion of the galvanized layer were evaluated through Dyne Test, T-bending Test, OM, SEM, and EDS analyses. The results indicated that the optimal degreasing solution composition consisted of NaOH (30 g/L), Na2CO3 (30 g/L), SLS (6 g/L), and room temperature additives (≤1 wt%).

Design and Implementation of Trusted Chatting Room Using Software TPM (소프트웨어 TPM 을 사용한 신뢰형 채팅룸 설계 및 구현)

  • Kennedy, Chinyere Grace;Cho, Dong-Sub
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.259-261
    • /
    • 2012
  • Chatting room has become widely using technology and it is vulnerable to the internet attackers. We proposed a chatting system using a Purebasic programming language to communicate across networks system. Chatting room text is a form of instant messaging between two or group of people. A Communication experiment was designed and implemented to confirm the validity of the developed chatting system on a trusted platform.

  • PDF

A Study of Ozone Occurrence Amount by Copy Machine Use in School and Around of School (학교 내.외 복사기 사용에 따른 오존 발생량 연구)

  • Noh Sun-Jin;Jung Kyung-Sick;Seo Seung-Pyo;Son Bu-Soon;Lee Jong-Wha;Lee Che-Won
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.58-65
    • /
    • 2006
  • This study is measured in at ozone concentrated places in school and outside of school where places that use copy machine and the others do not use one. Library copy room, Search room, Y-Copy, J-copy, R-shop are the places using copy machines and Search room, K-apt, J-billiard hall are the opposite. The measurement was held three times a day-the morning, the afternoon and the evening-once for each at indoor and outdoor. 8 places were lower than domestic ozone concentration standard(0.06ppm). The indoor ozone concentration average was the highest in Search room of school and was the lowest in Library restroom. The outdoor ozone concentration average was the highest in J-billiard hall.

Effect of Freezing of Paste on the Formation of Chou (반죽의 냉동처리가 Chou 형성에 미치는 효과)

  • Lee, Sun-Ok;kim, Myoung-Ae
    • Korean journal of food and cookery science
    • /
    • v.10 no.4
    • /
    • pp.405-411
    • /
    • 1994
  • This study was conducted to know the quality of chou made with flour pastes which were stored at different conditions of quick freezing, slow freezing, cold and room temperature. Also, this study included investigation of the chou properties such as expansion, sensory evaluation, degree of gelatinization, and physical and structural properties of paste were observed. There were not significant differences m diameter, height, volume, appearance, hollow formation, and sensory evaluation between the chou made with the paste stored at freezing condition and chou directly baked after pasting. Quick and slow freezing storages did not significantly affect the properties of chou, and the same results were obtained among the chou made with pastes thawed at room temperature and in microwave ovenrange. The chou of pastes stored at room temperature and in microwave ovenrange. The chou of pastes stored at room temperature and stored in refrigerator showed lowed expansion and value of sensory evaluation than those of frozen pastes. The paste stored at room temperature had the lowest hardness and viscosity compared with the other storage conditions. According to the observation of light microscope. the lipid bodies of the paste of freezing storage smaller those of the room temperature and refrigerator storage. The expantion of chou made with paste stored at room temperature was greatly decreased due to the high coalescence of lipid bodies, and also the paste components such as lipid, starch granule gluten at room temperature had inferior dispersion condition. The general tendency of the degree of gelatinization of chou were low in all treatments of paste. The values were 23.5%~46.0% in freezing, 77.3% in room temperature, 68.7% in directly baked after pasting, and 61.0% in cold storage, respectively. The formation and the taste of chou made with frozen paste were similar to those of chou directly baked pasting.

  • PDF

A Study on the Rehabilitation Room of Firefighters at Disaster Spot (재난현장 소방공무원의 회복실에 관한 연구)

  • Chae, Jin;Yim, Dong-Kyun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.116-125
    • /
    • 2020
  • This study intends to provide a model for the establishment of a rehabilitation room for the safety and rehabilitation of firefighters by proposing a basis for the establishment of a firefighter rehabilitation room at disaster sites. To achieve the research objectives, a questionnaire, frequency analysis, and variance analysis were conducted to assess the effectiveness of rehabilitation rooms for firefighters. Based on the results of the research, the policy suggestions for operating an effective rehabilitation room are as follows. An organization of the operation of the rehabilitation room should be established at each firefighting headquarters, and human resources must be secured for the operation of the rehabilitation room. In addition, detailed operating standards such as the operation contents of the rehabilitation room's operation manager and its operator, as well as its operation procedures should be prepared. Additionally, training to improve the rehabilitation room and its understanding is needed.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

A Study on the Perception of Infection Control in Ultrasound Diagnostic Room (초음파검사실 감염관리 인식에 대한 연구)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.367-374
    • /
    • 2020
  • The purpose of this study is to understand the infection prevention system and infection management perception of Ultrasound diagnostic room in medical institutions by sonographer's in general practitioner, semi and general hospitals. As a research method, a statistical analysis was conducted by surveying a total of 20 items in four category to determine the infection perception of sonographer's according to gender, age, working institution, and working period. As a result of infection awareness, males were in the ultrasound gel management category, women were in the transducer management category, all age groups were in the transducer management system category, and the General Practitioner, semi and general hospitals. were in the transducer management system category, and general hospitals showed a high degree of infection awareness in the category of disinfection and sterilization, and in the category of transducer management in the entire working period. In the results of the analysis of the correlation between the sub-factors of the perception of infection control in the Ultrasound diagnostic room the degree of correlation between each category showed a middle degree correlation(r>0.5) and a significant difference by category(p<.01). In conclusion, the prevention of infection in the ultrasound diagnostic room, which sonographer's firms think, was found to be the most efficient ultrasound diagnostic room infection control to implement transducer and gel management in accordance with the principles of disinfection and sterilization.