• Title/Summary/Keyword: School Ventilation

Search Result 684, Processing Time 0.027 seconds

The Changes of Temperature for Embedded Duct Ventilation System in Ondol (바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰)

  • Kim, Ok;Park, Jin-Chul;Kim, Nam-Gyu;Oh, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

A numerical study on the ventilation characteristics of rainfall in road tunnel (강우변화를 고려한 도로터널의 환기특성에 관한 수치해석)

  • Lee, Ho-Hyung;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.341-351
    • /
    • 2015
  • When rainfall occurred on road tunnel, that is likely to have influence upon ventilation force in the tunnels but the tunnels ventilation system did not consider factors of rainfall. Thus, this study investigated effects of rainfall upon ventilation force in the tunnels at no rainfall and changing of rainfall by 3 dimensional numerical method. Flow rate into road tunnels decreased as many as 52.34% at rainfall of 150 mm/hr, and pressure drop of road tunnel between entrance and exit decreased as many as 22.22%, so that rainfall had influence upon ventilation force in the tunnel. The number of necessary jet fan in road tunnels is 12 at no rainfall but, when rainfall of 80 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 16, when rainfall of 150 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 17. So, factor of rainfall should be considered at estimation of ventilation system of road tunnel.

Does the Mean Arterial Pressure Influence Mortality Rate in Patients with Acute Hypoxemic Respiratory Failure under Mechanical Ventilation?

  • Gjonbrataj, Juarda;Kim, Hyun Jung;Jung, Hye In;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • Background: In sepsis patients, target mean arterial pressures (MAPs) greater than 65 mm Hg are recommended. However, there is no such recommendation for patients receiving mechanical ventilation. We aimed to evaluate the influence of MAP over the first 24 hours after intensive care unit (ICU) admission on the mortality rate at 60 days post-admission in patients showing acute hypoxemic respiratory failure under mechanical ventilation. Methods: This prospective, multicenter study included 22 ICUs and compared the mortality and clinical outcomes in patients showing acute hypoxemic respiratory failure with high (75-90 mm Hg) and low (65-74.9 mm Hg) MAPs over the first 24 hours of admission to the ICU. Results: Of the 844 patients with acute hypoxemic respiratory failure, 338 had a sustained MAP of 65-90 mm Hg over the first 24 hours of admission to the ICU. At 60 days, the mortality rates in the low (26.2%) and high (24.5%) MAP groups were not significantly different. The ICU days, hospital days, and 60-day mortality rate did not differ between the groups. Conclusion: In the first 24 hours of ICU admission, MAP range between 65 and 90 mm Hg in patients with acute hypoxemic respiratory failure under mechanical ventilation may not cause significantly differences in 60-day mortality.

A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea (우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구)

  • Paik, Nam Won;Zong, Moon Shik;Lee, Hong Keun;Yun, Chung Ski;Ceong, Hoe Kyeong;Lee, Kyeong Hee;Lee, Na Roo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF

Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation (급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상)

  • Lee, Keu-Sung;Chung, Wou-Young;Jung, Yun-Jung;Park, Joo-Hun;Sheen, Seung-Soo;Hwang, Sung-Chul;Park, Kwang-Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

Investigating risk of overheating for school buildings under extreme hot weather conditions

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.277-287
    • /
    • 2017
  • This study examines the risk of overheating of a school building, under extreme hot weather conditions, in 14 locations in the United Kingdom using the overheating criteria defined in Building Bulletin 101 (BB101). The building was modelled as naturally ventilated, mechanically ventilated and in mixed mode and was simulated both for the current and the projected weather conditions of the 2050s. Under the current weather conditions, results of the simulations show that when naturally ventilated, the school building fulfils the BB101 criteria only in the areas of Edinburgh and Glasgow. In the simulations of the building as mechanically ventilated and in mixed mode, mechanical cooling was provided in order for the building to comply with the overheating criteria. A comparison of the required cooling loads between the two scenarios shows that application of mixed mode ventilation results in less cooling loads.

A Study on Spatial Design of Elementary School Based on Ecological Approach (생태적 개념을 도입한 초등학교 실내공간 디자인에 관한 연구)

  • 윤지영;송주은
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.118-126
    • /
    • 2004
  • This study started from the premise that the future elementary school should be designed based on ecological approach in order to restore the emotionality of children. This study aimed at providing a guideline for designing the interior of elementary schools based on ecological approach. Through literature review, the characteristics of ecological architecture and the regulations for green buildings were explored. Also 7 elementary schools which were evaluated as good school design through renowned books representing the ecological characteristics were chosen and analyzed. The results revealed that the school design included natural lighting by roof lighting, natural ventilation, greening, and use of natural materials. This study suggested three categories as a the guideline for the interior space of eco-school design; energy efficiency, greening and sustainability, which included natural lighting, natural ventilation, heating and cooling, planting, materials and water recycling.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

Sensitivity of Ozone to NOx and VOCs in a Street Canyon (도로 협곡에서 NOx와 VOCs에 대한 오존의 민감도)

  • Lee, Kwang-Yeon;Kwak, Kyung-Hwan;Park, Seung-Bu;Baik, Jong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.307-316
    • /
    • 2013
  • The sensitivity of ozone to $NO_x$ and volatile organic compounds (VOCs) emission rates under different ventilation rates and $NO_2-to-NO_x$ emission ratios in a street canyon is investigated using a chemistry box model. The carbon bond mechanism IV (CBM-IV) with 36 gaseous species and 93 chemical reactions is incorporated. $NO_x$ and VOCs emission rates considered range from 0.01 to $0.30ppb\;s^{-1}$ with intervals of $0.01ppb\;s^{-1}$. Three different ventilation rates and three different $NO_2-to-NO_x$ emission ratios are considered. The simulation results show that the ozone concentration decreases with increasing $NO_x$ emission rate but increases with increasing VOCs emission rate. When the emission ratio of VOCs to $NO_x$ is smaller than about 4, the ozone concentration is lower in the street canyon than in the background. On average, the magnitude of the sensitivity of ozone to $NO_x$ emission rate is significantly larger than that to VOCs emission rate. As the $NO_x$ emission rate increases, the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates decreases. Because the ozone concentration is lower in the street canyon than in the background, the increased ventilation rate enhances ozone inflow from the background. Therefore, the increase in ventilation rate results in the increase in ozone concentration and the decrease in the magnitude of the sensitivity of ozone to $NO_x$ and VOCs emission rates when the emission ratio of VOCs to $NO_x$ is smaller than about 4. On the other hand, the increase in $NO_2-to-NO_x$ emission ratio results in the increase in ozone concentration because the chemical ozone production due to the $NO_2$ photolysis is enhanced. In the present experimental setup, the contribution of the change in $NO_2-to-NO_x$ emission ratio to the change in the sensitivity of ozone to $NO_x$ emission rate is larger than that of the change in ventilation rate.

Numerical Analysis on the Improvement of Fume Mixing Ratio in the Push-Pull Local Ventilation System (급기-흡기 국소환기시스템의 성능개선에 관한 수치해석)

  • Yi, Chung-Seob;Suh, Jeong-Se;Yoon, Ji-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.867-872
    • /
    • 2010
  • Numerical analysis has been conducted to investigate the fluid flow and fume mixing ratio characteristics of scattering fume in a push-pull ventilation system and optimally improve the flow patterns of scattering fume in the existing ventilation system. This ventilation system has been simulated by using commercial CFD code. In the case of the existing system, although the air is sprayed from air-curtain to prevent the fume from being scattered in upper hood, the improved air supply hood can remove the fume from the wide area in the high pressure. It is verified that the deeper plating storage is more advantageous. Also, by installing the shied around the plating storage, the scattering of the fume to the atmosphere was prevented effectively by surrounding flux.