• Title/Summary/Keyword: School Building Cases

Search Result 242, Processing Time 0.031 seconds

Mitigation of seismic pounding between two L-shape in plan high-rise buildings considering SSI effect

  • Ahmed Abdelraheem Farghaly;Denise-Penelope N. Kontoni
    • Coupled systems mechanics
    • /
    • v.12 no.3
    • /
    • pp.277-295
    • /
    • 2023
  • Unsymmetrical high-rise buildings (HRBs) subjected to earthquake represent a difficult challenge to structural engineering, especially taking into consideration the effect of soil-structure interaction (SSI). L-shape in plan HRBs suffer from big straining actions when are subjected to an earthquake (in x- or y-direction, or both x- and y- directions). Additionally, the disastrous effect of seismic pounding may appear between two adjacent unsymmetrical HRBs. For two unsymmetrical L-shape in plan HRBs subjected to earthquake in three different direction cases (x, y, or both), including the SSI effect, different methods are investigated to mitigate the seismic pounding and thus protect these types of structures under the earthquake effect. The most effective technique to mitigate the seismic pounding and help in seismically protecting these adjacent HRBs is found herein to be the use of a combination of pounding tuned mass dampers (PTMDs) all over the height (at the connection points) together with tuned mass dampers (TMDs) on the top of both buildings.

Interior Project of IN-CHEON 'S' Elementary School Library (인천 'S' 초등학교 학교 도서관 구축 프로젝트)

  • Lee, Hyok-Jun;Lee, Jong-Sun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.219-220
    • /
    • 2005
  • This present study purposed to propose a plan of building a future oriented school library that supports teachers' teaching with various multimedia and Internet materials applicable in class immediately, helps students' self directed learning activities, and plays its role as a cultural center of the local community. As for research methods, this study examines the basic directions and characteristics of school libraries defined by the Ministry of Education and Human Resources Development, and investigates the current state of school libraries. In addition, we survey cases of library plans in Incheon, and suggest standards for planning and propose a plan. Ultimately, we establish a library plan for S Elementary School in Incheon and execute the plan and, in the course, derive ideas for satisfying students' demands with regard to their sentiment, stable and flexible layout and flow lines, facilities and space within the library, etc. What is more, we create indexes for library planning so that school libraries can contribute to various cultural activities and the development of local community beyond their functions as school library facilities.

  • PDF

The Effect of the Ground Composition on Thermal Environment in Multi -residential Building Block (공동주택 단지 내 지반 특성 및 지반 구성에 따른 열적 특성에 관한 연구)

  • Hwang, Hyo-Keun;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.88-97
    • /
    • 2009
  • In these days, it attracts our attention to create a green outdoor environment around the building block in urban area. Green space and permeable ground covering are increased by laws and regulations. According to these trends, variety researches for improving outdoor environment are accomplished at this moment. However, the problems for outdoor environment such as heat island effect and air contaminant in urban area are still reported. The purpose of this study is to examine the variables to affect the formation of outdoor thermal environment by quantitative analysis. As a initial study, in this paper, the effect of ground composition on changes of surface temperature and heat flux in multi-residential building were analyzed by field measurement and numerical simulation. Through field measurement, the surface temperature and heat flux of artificial ground in multi-residential building in Suwon city were measured. The result showed that the surface temperature was decreased by about $20^{\circ}C$ with afforestation of artificial ground compared with those of concrete covering. Moreover, the inner temperature of artificial ground was changed as same behaviors of outdoor temperature changes to depths of 20cm. In simulation, the effect of soil types and depth of artificial ground on the changes of the surface temperature and heat flux were analyzed. As results, the natural soil ground was more effective against lowering the surface temperature than any other cases in the analyzed cases.

Economic Analysis of Zero Energy Building in South Korea - focusing on Cost-Benefit analysis considering Social Cost - (공사비 변화에 따른 제로에너지건축물 경제성 분석 - 사회적비용을 고려한 비용편익 분석을 중심으로 -)

  • Kim, Jae-Moon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.147-157
    • /
    • 2020
  • With the increasing obligation to reduce greenhouse gas emissions to the building sector, the government has been gradually expanding its obligation to zero-energy buildings since 2020. Since the ZEB certification took effect in 2017, 48 preliminary and main certifications have been completed as of March 2019, and most of them are public buildings or even certified, but have earned Grade 5 of ZEB. This means that compared with the number of annual building permits registered in Korea, the figure is insignificant, and that it receives little if not mandatory. Therefore, this study investigated empirical cases of ZEB additional construction cost and conducted cost benefit analysis according to changes in ZEB additional construction cost based on a preliminary feasibility analysis project recently conducted by the KDI. In addition, considering the public buildings, the social costs were considered, and the cost-benefit analysis method was the same as the KDI's preliminary feasibility analysis method. The analysis shows that if the ratio of ZEB additional construction cost is more than 5 percent, it is analyzed that there is no economic feasibility, and considering that the ratio of additional construction cost in the cases of ZEB in Korea is 17 percent to 38 percent, it will not be easy to obtain ZEB certification in terms of cost. Finally, to narrow these differences in cost and economic aspects, the overseas low energy and ZEB incentive examples proposed measures such as the concept of subsidy payment in Illinois and the compensation of social costs to private ZEB.

A Study on the Applications of Renewable Energy in LEED (Leadership in Energy and Environmental Design) Certified School Projects - Focused on Solar and Thermal Energy - (LEED 인증 받은 학교건축사례에서 재생에너지 활용 연구 분석 - 태양광 및 태양열 에너지를 중심으로 -)

  • Yoon, Hea-Kyung;Woo, Seung-Hyun;Choi, Hyo-Sik
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.2
    • /
    • pp.25-32
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art solar energy system design cases among LEED(Leadership in Energy and Environmental Design) certified school projects and to explore the feasibilities for their applications in domestic school design. Investigating the sold wattages in some kinds of buildings, the wattages per an educational facility is the second-largest after that per an industrial facility. That shows that our attention should be actively directed to the utilization of New and Renewable Energy in school facilities. Therefore photovoltaics systems, lighting systems and solarthermal facilities of solar energy systems were analyzed in the LEED cases. Findings demonstrate that applications of solar energy systems in K-12 educational facilities have been executed more than those in higher educational facilities. However, K-12 educational facilities and higher educational facilities by private funds are not categorized as Green Buildings by Support for Making Green Buildings Act. That fact is needed to be amended. Besides that, design developments are needed for building integrated photovoltaics systems and solarthermal facilities in domestic educational facilities.

A Study on Color Planning of Elementary, Middle and High School Buildings -A Case Study of Domestic and Foreign School Buildings- (초(初).중등학교(中等學校) 건축(建築)의 색채계획(色彩計劃) 분석(分析) 연구(硏究) -국내.외 학교건축의 사례 중심으로-)

  • Kim, In-Hyeog;Kang, Byoung-Keun
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.74-87
    • /
    • 2011
  • The purpose of this study is in providing a systematic method for school building color scheme. This study analyzed the cases of color uses in domestic and foreign school buildings. The results from this study tells that the colors in school buildings should take into account the environmental, psychological and functional elements at the same time to effectively function as environmental color, effect color and induction color.

A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory (외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구)

  • Hwang, Ji Hyun;Bum, Do;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

Planning and Design Guidelines for the Utilization of Elementary Schools in Urban Housing Blocks (주거지내 초등학교의 활용을 위한 계획 방향)

  • 임은정;양우현
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.205-214
    • /
    • 2004
  • The intent of this study is to investigate the current situations and planning implications of elementary schools in urban housing blocks, and to propose the planning and design guidelines for them. The premise of this research is that an elementary school should function as a communal facility, shared by its community, so called open-school. 32 schools in three new towns were selected as sample cases and they were closely surveyed in terms of their site planning issues in residential blocks, and three sample open-elementary schools were analyzed in a comparative manner for finding their roles and functional fulfillment as a communal facility in the neighborhoods. Based on the findings, several planning principles and design techniques or devices are suggested for the utilization of elementary schools by local residents, mainly making issues of location, relationship to other facilities and open spaces in residential blocks, access, apartment layout, school building and outdoor spaces, and open program.

Identifying the Types of Collaboration in Community Health Promotion (지역사회 건강증진사업의 협력유형 분류)

  • Jang, Myung-Wha;Cho, Won-Sup;Yoon, Nan-He;Kwak, Min-Son;Yoo, Seung-Hyun
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.3
    • /
    • pp.125-135
    • /
    • 2009
  • Objectives: This study attempts to identify and categorize the types of collaboration that community health centers in Seoul planned to form in order to conduct health promotion programs. Methods: A content analysis was performed by reviewing the Phase 4 Community Health Plans for 2007-2010 of the 25 districts in Seoul. Results: In total, 614 cases of collaboration were identified which the community health centers in Seoul had planned for 2007-2010. These cases were grouped into 10 categories of collaboration activities: offering direct services through external venues utilizing external facilities; providing health education materials to partner agencies promoting health messages through media; running committees with collaborators inviting external experts; participating in external events; referring clients to external health services; connecting services; and miscellaneous. These types and cases were compared across community health promotion programs. Conclusion: Collaboration and partnership should be clearly defined for community health research and practice. Further research is needed to investigate the potential gap between plans for collaboration and actual collaboration activities, and to develop Korean models for collaboration building for community health promotion.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.