• Title/Summary/Keyword: Scene of a fire

Search Result 117, Processing Time 0.027 seconds

Development of a Classification System for an Electrical Fire Investigation (전기화재 조사를 위한 분류체계 개발)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

Public Safety & Security Unmanned Aerial Vehicle Heat resistance Environmental Test used in case of Building Fire (건축물 화재발생시 사용되는 재난치안용 무인기의 내열성 환경시험)

  • Kim, Da-Kyung;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.119-120
    • /
    • 2020
  • Recently, a building fire has occurred due to various influences. Accordingly, we are developing an public safety & security unmanned aerial vehicle for fire prevention and initial response to fire. The public safety & security unmanned aerial vehicle is used to grasp the traffic route to enter the fire engine in the event of a fire in a dense structure and to determine the scale of the fire and the area of danger of collapse around the fire site. In this study, an environmental test of the public safety & security unmanned aerial vehicle's heat resistance was performed in an environment simulating a fire scene.

  • PDF

Protocol Design for Fire Receiver­based Fire Detection Robots (화재수신기 기반의 화재감시로봇을 위한 프로토콜 설계)

  • Lim, Jong-Cheon;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.452-459
    • /
    • 2018
  • Conventional fire fighting robots are controlled by a remote control to monitor the fire scene or to suppress the fire. However, this method has a problem that it takes a long time to prepare robot and input it to fire place in the golden time after the fire, so that it can not sufficiently serve as a fire fighting robot. Using the autonomous driving fire monitoring robot, when a fire signal is generated, in conjunction with a fire receiver a moving robot takes a video of the fire scene and delivers the image to the fire department, so that the fire fighter can decide if it is real fire or not. Thereby it is possible to prevent a sudden spread of an accident by providing a quick judgment opportunity and at the same time suppressing the fire early. In this paper, we propose an architecture of the autonomous mobile fire monitoring robot and the communication protocol required for the robot to work with the fire receiver. A communication protocol is designed to control multiple fire monitoring robots in real time, and a communication with a fire receiver is designed as a hierarchical network to serve as an interface of an Ethernet network using wireless Wi-Fi. The fire monitoring robot and the wireless communication of the fire receiving period are implemented and the effectiveness of the operation is confirmed through the field test.

The Behavior Analysis on Arson Crime Scene (방화현장에 대한 행동분석)

  • Lee, Sang-Jun;Kim, Yun-Hee
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.25-39
    • /
    • 2006
  • Recently the arson crime is increased remarkably in comparison with different violent crimes and the pace of increase is very quick. But Social interest about the crime is still slight, it is a fact that the scientific and professional approaches about the crime is insufficient. This problem causes lower arrest rate of the arson crime than the other crime. So, we need to infer the behavior of a arsonist at the crime scene and analyze the profile and psychological state of the suspect from unique point at the crime scene scientifically and professionally. After arresting the arsonist, we interviewed him and compared a product of interview with our analysis previous to arrest.

  • PDF

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

A Study on the Actual Problems of Field Fire Supervision System(Focus to Dajeon City) (상주 소방감리업무의 현실적 문제점에 대한 연구 -대전지역을 중심으로-)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • In this study, supervision resides fire mission against problems associated with case studies and surveys done through the side of the field work, technical personnel, fire management, including fire code aspects classified into three kinds of items dealt with the issue. Started at the scene of the problem in terms of performance, the issue of the construction process, mainly dealt with the issue at the time of completion. Fire management side, supervisor of technical personnel, human resources management issues, contract issues, fire code level, the frequent revisions of fire regulations, supervision, processing delays of the resulting report, the problem resides with the expansion of Fire Supervision target was mentioned. Finally, the target for each hierarchical supervision, and resident supervisor of the need for supervision of work performance test was carried out by the correlation.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A study on the shapes of thermal corrosion in sandwich panel (샌드위치 패널의 열적 손상에 의한 부식 형상에 관한 연구)

  • Kim, Hyeon-Dong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.3 no.1
    • /
    • pp.43-46
    • /
    • 2003
  • In this experimental report, We introduce an idea of thermal corrosion in sandwich panel. In brief, Because the structures of sandwich panel are easily collapsed by thermal damage caused by a fire, it is very difficult to investigate a point and origin of fire. Therefore, If the shapes of thermal corrosion are reconstructed according to change of temperature and lapse time by experiment in sandwich panel, it is very simple task that fire scene investigators search for a point and origin of fire. As a result, we present the difference of thermal corrosion between samples which are applied heat by many-sided variable, such as temperature, heating time, lapse time, humidity, and others.

  • PDF

A Study on Necessity of Expansion and Reorganization of Courses Related to Fire Investigation (화재조사 관련 교과목의 확대와 개편의 필요성에 관한 연구)

  • Choi, Jin-Man;Kim, Kil-Hwan;Lee, Chang-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.42-50
    • /
    • 2011
  • To foster fire investigation professionals and expand career opportunities for graduates of fire science majors, it is extremely important to expand and reorganize courses which are related to fire investigation. Only 30 percent of universities have fire investigation related courses, and the courses only offer theoretical materials. As a result, it has a great limitation to teach essential knowledge which is required at a fire scene. This study suggests to classify fire investigation-related-courses in to fire investigation course and fire identification course. In addition, the study proposes ways to standardize curricula which enables students to acquire Certified Fire and Explosion Investigator (CFEI).

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF