• 제목/요약/키워드: Scattering, Radiation

검색결과 389건 처리시간 0.026초

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

배기 후류의 적외선 방사 특성 모사를 위한 수치적 연구 (A NUMERICAL SIMULATION OF INFRARED RADIATION OF EXHAUST PLUME)

  • 장우;양영록;박경린;명노신;조태환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.422-425
    • /
    • 2010
  • The infrared radiation of exhaust plume was investigated numerically by a finite volume method (FVM) with anisotropic scattering particles. The exhaust plume is considered to absorb, emit and scatter radiant energy isotropically as well as anisotropically. The spatial and spectral distribution characteristics were obtained for the detection wavelength with $2.7{\mu}m$. The radiative intensities were presented for the different detective direction.

  • PDF

한국원자력연구소 중성자교정실에 대한 중성자산란보정인자 결정연구 (Comparison Study of Experimental Neutron Room Scattering Corrections with Theoretical Corrections in RCL's Calibration Facility at KAERI)

  • 윤석철;장시영;김종수;김장렬;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제22권1호
    • /
    • pp.29-33
    • /
    • 1997
  • 중성자교정실내에서 $D_2O$ 감속 $^{252}Cf$중성자선원을 사용하여 계측기를 교정할 때는 그 계측기에 대한 교정실산란보정 인자를 미리 결정하여야 한다. 이러한 교정실산란보정인자는 계측기의 종류, 교정거리, 교정실형태에 따라 다르게 결정된다. 본 연구에서는 한국원자력연구소에서 운영하는 2차 표준중성자교정실에서 한가지의 열형광선량계와 2가지의 구형검출기에 대한 교정실산란보정인자를 실험적으로 결정하였고 본소의 2차 표준중성자교정실조건에 의하여 이론적으로 예측한 값과 비교하였다. 비교한 결과 실험하여 얻어진 상기의 3가지 계측기에 대한 교정실산란보정인자가 이론적으로 예측한 결과와 최대 약 10% 이내에서 일치하였다.

  • PDF

Relativistic Radiation Belt Electron Responses to GEM Magnetic Storms: Comparison of CRRES Observations with 3-D VERB Simulations

  • 김경찬
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.90.1-90.1
    • /
    • 2012
  • Understanding the dynamics of relativistic electron acceleration, loss, and transport in the Earth's radiation belt during magnetic storms is a challenging task. The U.S. National Science Foundation's Geospace Environment Modeling (GEM) has identified five magnetic storms for in-depth study that occurred during the second half of the Combined Release and Radiation Effects Satellite (CRRES) mission in the year 1991. In this study, we show the responses of relativistic radiation belt electrons to the magnetic storms by comparing the time-dependent 3-D Versatile Electron Radiation Belt (VERB) simulations with the CRRES MEA 1 MeV electron observations in order to investigate the relative roles of the competing effects of previously proposed scattering mechanisms at different storm phases, as well as to examine the extent to which the simulations can reproduce observations. The major scattering processes in our model are radial transport due to Ultra Low Frequency (ULF) electromagnetic fluctuations, pitch-angle and energy diffusion including mixed diffusion by whistler mode chorus waves outside the plasmasphere, and pitch-angle scattering by plasmaspheric hiss inside the plasmasphere. We provide a detailed description of simulations for each of the GEM storm events.

  • PDF

유한체적법에 의한 로켓플룸 저부가열의 열복사 모델 (Thermal radiation model for rocket plume base heating using the finite-volume method)

  • 김만영;백승욱
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3598-3606
    • /
    • 1996
  • The finite volume method for radiation is applied to investigate a radiative heating of rocket base plane due to searchlight and plume emissions. Exhaust plume is assumed to absorb, emit and scatter the radiant energy isotropically as well as anisotropically, while the medium between plume boundary and base plane is cold and nonparticipating. Scattering phase function is modelled by a finite series of Legendre polynomials. After validating benchmark solution by comparison with that of previous works obtained by the Monte-Carlo method, further investigations have been done by changing such various parameters as plume cone angle, scattering albedo, scattering phase function, optical radius and nozzle exit temperature. The results show that the base plane is predominantly heated by the plume emission rather than the searchlight emission when the nozzle exit temperature is the same as that of plume.

THE EFFECT OF ATMOSPHERIC SCATTERING AS INFERRED FROM THE ROCKET-BORNE UV RADIOMETER MEASUREMENTS

  • Kim, Jhoon
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.87-93
    • /
    • 1997
  • Radiometers in UV and visible wavelengths were onboard the Korean Sounding Rocket(KSR)-1 and 2 which were launched on June 4th and September 1st, 1993. These radiometers were designed to capture the solar radiation during the ascending period of the rocket flight. The purpose of the instrument was to measure the vertical profiles of stratospheric ozone densities. Since the instrument measured the solar radiation from the ground to its apogee, it is possible to investigate the altitude variation of the measured intensity and to estimate the effect of atmospheric scattering by comparing the UV and visible intensity. The visible channel was a reference because the 450-nm wavelength is in the atmospheric window region, where the solar radiation is transmitted through the atmosphere without being absorbed by other atmospheric gases. The use of 450-nm channel intensity as a reference should be limited to the altitude ranges above the certain altitudes, say 20 to 25km where the signals are not perturbed by atmospheric scattering effects.

  • PDF

Multilevel acceleration of scattering-source iterations with application to electron transport

  • Drumm, Clif;Fan, Wesley
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1114-1124
    • /
    • 2017
  • Acceleration/preconditioning strategies available in the SCEPTRE radiation transport code are described. A flexible transport synthetic acceleration (TSA) algorithm that uses a low-order discrete-ordinates ($S_N$) or spherical-harmonics ($P_N$) solve to accelerate convergence of a high-order $S_N$ source-iteration (SI) solve is described. Convergence of the low-order solves can be further accelerated by applying off-the-shelf incomplete-factorization or algebraic-multigrid methods. Also available is an algorithm that uses a generalized minimum residual (GMRES) iterative method rather than SI for convergence, using a parallel sweep-based solver to build up a Krylov subspace. TSA has been applied as a preconditioner to accelerate the convergence of the GMRES iterations. The methods are applied to several problems involving electron transport and problems with artificial cross sections with large scattering ratios. These methods were compared and evaluated by considering material discontinuities and scattering anisotropy. Observed accelerations obtained are highly problem dependent, but speedup factors around 10 have been observed in typical applications.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Line-Source Scattering from Slant Strips

  • Ock, Jang-Soo;Eom, Hyo-Joon
    • Journal of electromagnetic engineering and science
    • /
    • 제9권4호
    • /
    • pp.229-231
    • /
    • 2009
  • Electromagnetic scattering from slant strips excited by a line source is investigated. Boundary conditions are applied to obtain simultaneous equations for discrete modal coefficients. Computations are performed to illustrate the effects of line-source scattering on radiation patterns.

다중격자 유한체적법에 의한 복사열전달 해석 (A Study of n Multigrid Finite-Volume Method for Radiation)

  • 김만영;변도영;백승욱
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.135-140
    • /
    • 2003
  • The convergence of finite volume method (FVM) or discrete ordinate method (DOM) is known to degrade for optical thickness greater than unity and large scattering albedo. The present article presents a convergence acceleration procedure for the FVM based on a full approximation storage (FAS) multigrid method. Among a variety of multigrid cycles, the V-cycle is used and the full multigrid algorithm (FMG) is applied to an analysis of radiation in irregular two-dimensional geometry. Solution convergence is discussed for the several cases of various optical thickness and scattering albedo. At small scattering albedo and optical thickness, there is no advantage to using the multigrid method for calculation CPU time. For large scattering albedo greater than 0.5 and optical thickness greater than unity, however, the multigrid method improves the convergence and the solution is rapidly obtained.