• Title/Summary/Keyword: Scattered Radiation Dose

Search Result 134, Processing Time 0.025 seconds

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

Characteristics of Scattered Rays Depending on the Use of a Flattening Filter (선속평탄 여과판 사용 유무에 따른 산란선 특성)

  • Jin, SeongJin;Park, ChulWoo;Je, Jaeyong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.15-19
    • /
    • 2016
  • This Study aims at measuring scattered rays depending on the use of a flattening filter when radiation is irradiated using a linear accelerator. measurement of the scattered rays, an ionization chamber was used, and the energy of the irradiated radiation was 6 MV and 10 MV. The ionization chamber was located at the spot 15 cm, 25 cm, 35 cm and 45 cm far away from the center of gantry rotation, and the scattered rays were measured according to whether a flattening filter was used or not and to the distance. As the result of investigation of 100 cGy about each energy, when the flattening filter was not used with 6 MV, it occurred at a low level of 65%, and with 10 MV at that of 55%. In other words, it's been concluded that when a flattening filter is not used for radiation dose of the parts around the critical organ, scattered rays generate in a small quantity, and it's a useful way to decrease the stochastic effect of radiation.

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

Measurement of Spatial Scattered Dose Distribution According to Presence or Absence of Radiation Shielding in the Operating Room (수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정)

  • Do, Sang-Lock;Cho, Pyong-Kon;Kim, Seong-Jin;Jung, Dong Kyung
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.549-556
    • /
    • 2017
  • This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing $30^{\circ}$ with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was $0^{\circ}$, $90^{\circ}$ and $180^{\circ}$, was $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, and $2.69{\pm}0.15mSv/h$ in the $270^{\circ}$ direction, and was $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, and $1.37{\pm}0.11mSv/h$ after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction $90^{\circ}$ with 50 cm distance was $30^{\circ}$, $60^{\circ}$, $120^{\circ}$, was $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, and $5.40{\pm}0.22mSv/h$ in $150^{\circ}$, and was $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, and $1.92{\pm}0.13mSv/h\;mR/h$ after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures.

Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology (인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가)

  • Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.

A Study on the Surface Dose Distribution by Scattered and Leakage Radiation in Radiation Therapy (방사선 치료 시 산란선 및 누설선에 의한 표면선량 분포에 관한 연구)

  • Kang, Jongsu;Jung, Dongkyung;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.351-357
    • /
    • 2018
  • During radiation therapy, the patient is exposed to secondary radiation by scattered and leakage radiation. For the diagnostic radiation, guidelines for reducing the patient's exposure as the diagnostic reference level are provided. However, in the case of therapeutic radiation, even though the radiation dose by the secondary radiation is considerable, the prescription dose is not limited because of the reason of the therapeutic efficiency. The purpose of this study was to evaluate the secondary radiation that the patient could be received at the peripheral tissue during the radiotherapy using the linear accelerator with the radiophotoluminescent glass dosimeter. In addition, we measured the degree of saturation of the luminescent amount according to the build-up characteristic of the radiophotoluminescent glass dosimeter. As a result of carrying out this study, the exposure dose decreased drastically farther away from the treatment field. When the head was irradiated with 1 Gy, the neck could be exposed to 18.45 mGy. When the same dose was irradiated at the neck, 15.55 mGy of the head and irradiated at the chest, 14.26 mGy of the neck and irradiated at the pelvis, 1.14 mGy of the chest were exposed separately. The degree of saturation of the luminescent intensity could be overestimated by 1.8 ~ 4.8% depending on time interval for 3 days.

A Study on Structural Shielding Design of Afterloading Therapy Room (강내치료실 차폐에 대한 고찰)

  • Yun, Suk-Rok;Kim, Myung-Ho;Shin, Dong-Oh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.31-40
    • /
    • 1987
  • In the case of designing a high dose rate remote controlled afterloading treatment room with existing hospital facilities. We must construct the effective protective barriers so as to reduce the primary and scattered radiation up to the maximum permissible dose level. It is difficult to reinforce the barrier thickness of the shielding requirements because of the limited space and the problem of the existing building structure at the surrounding area. Therefore we can reduce the intensity of primary radiation to the required degree at the location of interest with installing the appropriate I shaped Pb barriers between the radiation source and the shielding wall of the concrete. As a result, it was possible to reduce the intensity of the primary radiation below the M.P.D level by using additional Pb barriers instead of increasing thickness of concrete wall.

  • PDF

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.