선량과 선질에 따른 형광량계 응답특성 (The Response of Fluorescence Meter according to X-ray dose and quality)

  • 김정민;김명준;윤종민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.71-75
    • /
    • 1995
  • In order to establish the photographic effects and sensitivity of various screens, fluorescence meter is used with convenience. When the radiation quality has been fixed the fluorescence has increased in proportion to X-ray dose. However, the response of fluorescence meter has the dependency of X-ray quality in accordance with KVP. as well as the difference of screen and scatter fraction can influence on the response of fluorescence meter. Using accurate fluorescence meter as a radiation detecter and as for a proper supervision the sensitive materials, we have to aware of the meter's dependency of X-ray quality and the scatter fraction.

  • PDF

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.

광다이오드 배열소자를 이용한 디지탈 X선 촬영 시스템의 설계에 관한 연구 (Design of the Digital X-ray System using Photo-diode Arrays)

  • 박광석;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권2호
    • /
    • pp.149-154
    • /
    • 1984
  • A digital X-ray system was designed using photo-diode arrays. This system consists of the following five sub-units; (1) slit and driving system (2) X-ray detection system (3) data-conversion system (4) computer (5) image display system. Using this system, one can obtain scatter-free, high contrast, digitally formatted, high quality image, as compared with the conventional film-based X-ray system.

  • PDF

진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비 (Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation)

  • 강영한;권순무;김부순
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.499-505
    • /
    • 2012
  • 개인피폭선량계인 열형광선량계(TLD)와 광자극형광선량계(OSLD)를 진단방사선 영역에서 사용할 때 에너지와 조사 횟수, 투시촬영 시간, 산란선 노출 일 수 등에 따라 측정값이 차이가 있는지를 상대비와 상대비 간격으로 알아보았다. 에너지에 따라서는 TLD의 상대비($1.81{\pm}0.41$)가 OSLD의 상대비($1.40{\pm}0.26$)보다 높았고, 조사 횟수에 따라서는 TLD의 상대비($2.10{\pm}0.10$,)보다 OSLD의 상대비($2.33{\pm}0.09$)가 더 높았다. 투시촬영 시간에 따른 상대비와 산란선 노출일수에 따른 상대비는 두 선량계가 유의한 차이가 없었으나 산란선 노출일수에 따른 상대비의 간격이 0.2 이내로 나타나 직접선의 상대비 간격보다 좁았다. 이는 직접선의 측정결과보다 산란선의 측정에 있어 TLD와 OSLD의 결과값에 신뢰가 높다고 할 수 있다. 따라서 방사선 피폭상황에 따라 선량계 간에 상대비가 다소 차이가 날 수 있음을 인지하고, 경우에 따라서는 두 가지 선량계를 이용하여 교차평가를 함으로써 선량 측정 결과값에 대한 신뢰성을 높일 수 있을 것이다.

디지털 맘모 디텍터 성능평가를 위한 몬테카를로용 산란선 제거 그리드 작성에 관한 연구 (Monte Carlo Simulation-Based Mammographic Anti-Scatter Grids to Evaluate Performance of Digital Mammography Detector)

  • 김예지;조혜진;윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.1-6
    • /
    • 2024
  • In Recent years, there has been a noticeable increase in the global incidence of breast cancer, with approximately 2.3 million cases of female breast cancer reported worldwide in 2020. Numerous studies are currently underway to enhance the accuracy of breast cancer diagnosis through the development of digital mammography detectors. This study aims to create Monte Carlo simulation-based mammographic anti-scatter grids and investigate their utility in evaluating the performance of digital mammography detector. Two types of mammographic anti-scatter grids, MAM-CP and Senographe 600T HF, were created using Monte Carlo simulation software (MCNPX 2.7.0), with grid ratios of 3.7 : 1 and 5 : 1, respectively. The grid physical characteristics (sensitivity, exposure factor, contrast improvement ratio) were calculated based on the KS C IEC60627 in the simulations using two X-ray qualities, RQA-M2 (28 kVp) and MW4 (35 kVp). As the X-ray tube voltage increased from 28 kVp to 35 kVp, sensitivity and exposure factor exhibited a decreasing trend, while contrast improvement ratio demonstrated an increasing trend. With an increase in grid ratio from 3.7 : 1 to 5 : 1, all physical characteristics showed an upward trend. Our results were consistent with a previous study that conducted measurements of physical properties using a real phantom. However, the pattern of change in the contrast improvement ratio with X-ray tube voltage differed from the previous study.

Calculation of X-ray attenuation coefficients for normal and cancerous breast tissues

  • Aysun Boke
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.241-246
    • /
    • 2024
  • The study was carried out by numerical integration based on the diffraction properties and elemental composition. The elemental compositions of breast tissues in the literature were tested. The photon attenuation coefficients calculated using the recent elemental composition were found within 0.2-16% for adipose tissue and within 0.04-17% for glandular tissue with the experimental reference data. The attenuation coefficients of cancerous breast tissue calculated according to the elemental content previously measured in breast cancer patients were found within 0-17% with experimental data in the literature. The attenuation coefficients are of great interest to medical research. To calculate realistic attenuation coefficients, the characteristic coherent scatter, which is most intense at small angles, must be considered. For this reason, experimentally measured form factor data were reviewed, and the most compatible one with the theoretical form factor data produced in this study was used at low momentum transfer x (0 < x ≤ 8 nm-1). The differential linear coherent scattering distributions were calculated for an energy value of 17.44 keV and compared with their experimental counterparts.

일반촬영 시 거리역자승법칙에 따른 산란선 감약에 관한 연구 (The Study About Attenuation of Scatter Ray According to Distance Inverse Square Law at General Projection)

  • 전민철;임현수;한만석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.183-188
    • /
    • 2011
  • 거리 역자승 법칙에 관한 엑스선 감약의 정도를 파악하고 이를 산란선 발생에서 적용하여 방사선사의 피폭을 저감할 수 있는 공간을 찾도록 알아보고자 하였다. 관전류량 10 mAs, 관전압 60 kVp, 70 kVp, 81 kVp, 90 kVp, 각각의 거리 60 cm, 120 cm, 180 cm에서 1차 선량을 측정하고, 산란선은 관전류량 20 mAs, 관전압 70 kVp, phantom의 중심부로부터 전면과 후면으로 42.5 cm, 52.5 cm, 62.5 cm 떨어진 곳에서 음 양극(좌우측)으로 각각 10 cm씩 60 cm까지 측정하였고, 거리역자승법칙과 비교하기 위해 전 후방 각각 42.5 cm, 85 cm, 127.5 cm에서 산란선을 측정하였다. 1차선은 거리가 2배에서는 20.52 mR(27.20%), 28.58 mR(25.20%), 38.82 mR(26.32%), 48.20 mR(26.27%)로 감약되고 거리가 3배에서는 7.06 mR(8.91%), 9.90 mR(8.73%), 13.64 mR(9.25%), 16.60 mR(9.05%)로 감약되는 것을 알 수 있었고, 산란선은 전 후방 각각 거리가 2배에서는 0.15 mR(23.09%), 0.15 mR(22.08%) 3배에서는 0.07 mR(10.43%), 0.06 mR(8.83%)로 감약되었다. 산란선의 발생량이 평균적으로 3사분면이 적게 발생하기에 환자를 붙잡고 촬영할 시에는 3사분면의 피사체에서 가능하면 거리를 두고 환자를 잡는 것이 피폭선량을 줄일 수 있다.

Back Scatter Radiation이 CR영상(影像)에 미치는 영향(影響)

  • 이후민;김학성;조남수;고승일
    • 대한디지털의료영상학회논문지
    • /
    • 제2권1호
    • /
    • pp.92-95
    • /
    • 1996
  • Computed Radiography(CR) is a relatively new technology that relies on an image plate(IP) as an alternate x-ray sensor to screen/film. Standard CR cassettes do not have lead foil behind the IP to control scatter radiation. The result of this study indicate that such control is needed. In most screen/film cassettes, that lines the rear of the cassette eliminates back scatter radiation. This study was performed to Investigate on the effects of back scatter in CR images by size of exposure field, distance between the CR cassette and the wall of radiography room. 1. It showed artifacts from hinges and clips located on the back of CR cassette by back scatter radiation. 2. The greater effects of back scatter radiation in CR images was attributed to the greater size of exposure field and the longer distance between the CR cassette and the wall of radiography room.

  • PDF

흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究) (A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography)

  • 유병헌;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF