• Title/Summary/Keyword: Scanning height

Search Result 246, Processing Time 0.019 seconds

Influence of Shading and Irrigation on the Growth and Development of Leaves Tissue in Hot Pepper (고추 고온기 재배 시 차광과 관수가 생육 및 엽육조직 발달에 미치는 영향)

  • Lee, Sang Gyu;Choi, Chang Sun;Lee, Jun Gu;Jang, Yoon Ah;Lee, Hee Ju;Chae, Won Byoung;Do, Kyung Ran
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.448-453
    • /
    • 2014
  • Influences of shading and irrigation in summer hot pepper cultivation on the plant growth and mesophyll tissue were investigated. Hot pepper plants were exposed to three shade levels (0, $30{\pm}5$ and $80{\pm}5%$) and irrigated or non-irrigated in greenhouse condition. Plant height and leaf area were highest in 30% shading and stem diameter and fresh and dry weights were highest in no shading. Plant growth was better in rain shelters with irrigation than in those without irrigation. The numbers of hot pepper fruits in the beginning of harvest were 49 in rain shelters without irrigation and shading, 22 in those with irrigation and without shading, 5 in those without irrigation with 30% shading, and 1 in those with irrigation and 30% shading. However, 80% shading showed lowest flower number and flower abscission, resulting in no fruit set, regardless of irritation. This is because carbohydrate translocation from leaves to reproductive organs may be not enough for developing fruits due to the lack of sunlight. The yield of hot pepper tended to be higher in rain shelter with irrigation than in those without irrigation. In optical microscopy observation, the thickness and development of mesophyll tissues decreased as increasing the degree of shading but no effect of irrigation on mesophyll tissues was observed. When stomata were observed with scanning electron microscope (SEM), the shape of stomata was normal but tissues surrounding stomata were slightly wrinkled in plants grown under 30% shading. The large number of abnormal stomata and wrinkled leaves was observed among plants grown in rain shelters with 80% shading. In plants grown in rain shelters without irrigation, tissues surrounding stomata were wrinkled and 10-20% decrease in the number of stomata was observed. Therefore, in hot pepper cultivation in summer with high temperature, shading was not effective for fruit yield and mesophyll tissue development; if shading is unavoidable, high degree of shading is not advisable. Further studies are needed for appropriate cultivar selection and environment-control techniques in hot pepper cultivation in summer with high temperature.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Feasibility Assessment on the Application of X-ray Computed Tomography on the Characterization of Bentonite under Hydration (벤토나이트 수화반응 특성화를 위한 X선 단층촬영 기술 적용성 평가)

  • Melvin B., Diaz;Gyung Won, Lee;Seohyeon, Yun;Kwang Yeom, Kim;Chang-soo, Lee;Minseop, Kim;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • Bentonite has been proposed as a buffer and backfill material for high-level radioactive waste repository. Under such repository environment conditions, bentonite is subjected to combined thermal, hydrological, mechanical, and chemical processes. This study evaluates the feasibility of applying X-ray CT technology on the characterization of bentonite under hydration conditions using a newly developed testing cell. The cylindrical cell is made of platic material, with a removable cap to place the sample, enabling to apply vertical pressure on the sample and to measure swelling pressure. The hydration test was carried out with a sample made of Gyeonju bentonite, with a dry density of 1.4 g/cm3, and a water content of 20%. The sample had a diameter of 27.5 mm and a height of 34 mm. During the test, water was injected at a constant pressure of 0.207 MPa, and lasted for 7 days. After one day of hydration, bentonite swelled and filled out the space inside the cell. Moreover, CT histograms showed how the hydration process induced an initial increase and later progressive decrease on the density of the sample. Detailed profiles of the mean CT value, CT standard deviation, and CT gradient provided more details on the hydration process of the sample and showed how the bottom and top regions exhibited a decrease on density while the middle region showed an increase, especially during the first two days of hydration. Later, the differences in CT values with respect to the initial state decreased, and were small at the end of testing. The formation and later reduction of cracks was also characterized through CT scanning.

Effect of surface sealant on surface roughness of dental composite with different surface roughness (서로 다른 거칠기의 복합레진에 표면 강화제 도포시 표면 거칠기의 변화)

  • Dong-Ah Shin;Seon-Ju Jin;Kkot-Byeol Bae;In-Nam Hwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.195-203
    • /
    • 2023
  • Purpose: This study aimed to evaluate the influence of surface sealants on the surface roughness of composite resins. Materials and Methods: The study used microfilled composite resin (Metafil CX, Sun Medical Co.) and hybrid composite resin (AeliteTM LS posterior, Bisco). Sixty specimens (8 mm in diameter and 4 mm in height) of each composite resin type were prepared and divided into 3 groups. Each specimen was ground with 600, 1000, and 2000-grit sandpaper. The Surface roughness (Ra) values were measured using a surface roughness tester (SJ-301, Mytutoyo) before and after surface sealant application. Surface sealants, BisCoverTM LV (Bisco), Optiguard® (Kerr), and Seal-n-ShineTM (Pulpdent), were applied to the specimens, as instructed and observed by scanning electron microscope (JSM-7500, JEOL) and atomic force microscope (MultiMode IV, Veeco Instruments). Results: Specimens ground with 600-grit sandpaper coated with surface sealants exhibited significantly lower Ra values than the untreated group (P < 0.05). Specimens ground with 1000 and 2000-grit sandpaper showed statistically no difference. There was no significant difference in surface roughness among BisCoverTM LV, Optiguard®, and Seal-n-ShineTM. SEM and AFM revealed remarkably decreased microdefects on the surfaces of composite resins after surface sealant application. Conclusion: Surface sealants can influence surface roughness when applied on the rough surface of composite resins but not on highly polished composite resins.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF