• Title/Summary/Keyword: Scanning height

Search Result 248, Processing Time 0.027 seconds

The Change of Facial Contouring after Unilateral Injection of Botulinum Toxin in Unilateral Masseter Hypertrophy Patients (편측성 교근비대 환자에서 편측 보툴리눔 독소 주사 후 안모의 변화)

  • Cha, Yu-Rim;Kim, Young-Gun;Kim, Ji-Hyun;Shim, Young-Joo;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.247-251
    • /
    • 2011
  • Botulinum toxin type A (BoNT-A) is used for treating bilateral masseter hypertrophy since 1994. Recently there have been more clinical studies in this area, with some authors reporting that BoNT-A can reduce the size of the masseter muscle, as documented by photography, ultrasonography, computed tomography, and 3D(three dimensional) laser scan. However, earlier studies were only for bilateral masseter hypertrophy cases, not for unilateral masseter hypertrophy cases. The aim of this study was to use 3D laser scanning to evaluate changes in the external facial contour induced by unilateral BoNT-A injection. BoNT-A was injected into hypertrophic masseter muscle unilaterally in 10 patients with asymmetric masseter hypertrophy. The clinical effects of unilaterally injected BoNT-A were evaluated before the injection and 4, 8, and 12weeks after the injection using 3D laser scan. And the mean values of both sides (injection and non-injection sides) were compared with. At injection side, mean values of the volume and the bulkiest height at each time point diminished significantly between pre-injection and 4, 8, and 12weeks post-injection. At non-injection side, in contrast, mean values of the volume and the bulkiest height diminished also but less than that of injected side, and there was no statistical significance. In this limited study, we concluded that the unilaterally BoNT-A injection side showed greater mean values of the reduction of muscle volume than non-injection side at 4, 8, and 12 weeks after the injection.

Effect of a Silicate Fertilizer Supplemented to a Medium on the Growth and Development of Potted Plants (배지에 첨가한 규산질 비료가 분식물의 발근과 생육에 미치는 영향)

  • Bae, Min Ji;Park, Yoo Gyeong;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • This experiment was carried out to examine the effect of a silicate fertilizer on the growth and development of potted plants. Cutting of Kalanchoe blossfeldiana 'Kaluna' and 'Taos', and Dianthus caryophyllus L. 'Kazan' and 'Tula' were grown in 50 and 128-cell plug trays, respectively. Rooted cuttings transplanted to the mixture of a commercial medium and perlite (5:1, v/v) supplemented with a silicate fertilizer at 0, 40, 80, 120 or $160g{\cdot}L^{-1}$ medium was evaluated. A silicate fertilizer supplementation at $40g{\cdot}L^{-1}$ medium resulted in the greatest plant height, leaf thickness, and root fresh and dry weights in both kalanchoe and carnation. However, plant height was suppressed in the treatment of a silicate fertilizer supplementation at higher concentrations in both kalanchoe and carnation. According to the scanning electron microscope images of transversal sections of tissues of roots and leaves in kalanchoe and carnation, the treatment of a silicate fertilizer supplementation at $40g{\cdot}L^{-1}$ medium resulted in plants with more compact tissue than the control.

The Study of Technical Error Analysis on BMD Using DEXA (이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석)

  • Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Purpose: This study was conducted to search for the type of technical error in DEXA(dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. Materials and Methods: The changes of BMD($g/cm^2$, T-score) by patients information(Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age(5, 10), weight(10, 20 kg), height(5, 10 cm), manopause age(5, 10) increase & decrease respectively. Scanning region(L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean(precision 1%) were carried out. Results: The error of patient information(Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to $0.063\;g/cm^2$, 0.3 and involving L-5 increased to $0.077\;g/cm^2$, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to $0.006\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.15, each. In hip ROI, Upper and left shift(0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift(lesser trochanter below), the BMD and T-score increased $0.031\;g/cm^2$, 0.3 and in 1 cm $0.094\;g/cm^2$, 0.65, each. In forearm ROI, the BMD and T-score decreased $0.042\;g/cm^2$, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased $0.008\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. Conclusion: There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to $BMD(g/cm^2)$ and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In forearm processing, the ROI have to included wrist, radius and ulnar.

  • PDF

Clinical Trial of Taeeumjowui-Tang(Taiyintiaowei-tang) on Obese Patients - Randomized, Double Blind, Placebo-Controlled Study - (비만 환자에 대한 태음조위탕(太陰調胃湯) 임상연구 - 무작위배정, 이중맹검, 위약·대조군 임상시험 -)

  • Li, Ji-Eun;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.197-213
    • /
    • 2010
  • Objectives : The clinical trial was designed to investigate the safety and effects of Taeeumjowui-tang(Taiyintiaowei-tang) extracts on the change of the weight, body compositions, serum in obese patients. Methods : This was a 12-weeks, randomized, double blind, placebo-controlled clinical trial. Patients with a body mass index of either greater than $30kg/m^2$ or between 27 and $30kg/m^2$ with controlled hypertension, diabetes, hyperlipidemia were considered eligible. Participants of 41 obese patients were randomized either to Taeeumjowui-tang(Taiyintiaowei-tang)(23) or placebo(18). After 12 weeks of treatment, we measured anthropometric factors(weight, height, waist circumference, BMI(body mass index) etc.), abdominal fat area by CT(computed tomography)scanning, serum lipid(total cholesterol, tryglyceride, HDL-cholesterol, LDL-cholesterol), blood lever of variety(AST, ALT, BUN, creatinine etc.). Adverse events also evaluated. Results : After 12 weeks of treatment mean weight, waist-circumference, total cholesterol, LDL-cholesterol and score of KEAT-26 were significant changed in Taeeumjowui-tang(Taiyintiaowei-tang). There were no serious adverse events in either groups. Conclusions : There were limited in this study that is conducted within a short period of 12 weeks. but its weight and WC(waist circumference), WHR(waist hip ratio), total cholesterol, LDL-cholesterol and score of KEAT-26 loss effect was significant and it had few adverse events.

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

EXPRESSION OF OSSEOINTEGRATION-RELATED GENES AROUND TITANIUM IMPLANT: BMP2, BMP4 (타이타늄 임프란트 주위 골유착 관여 유전자의 발현: BMP2, BMP4)

  • Shim, Cheong-Hwan;Jee, Yu-Jin;Song, Hyun-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.4
    • /
    • pp.307-314
    • /
    • 2005
  • After dental implant are planted into their bony site among the various growth factors associated with bone formation. BMP is expressed in the bone surrounding the implant fixture. By taking a close look at BMP2, BMP4 which are growth factors that take put in bone formation, its histologic features and radiographic bone healing patterns we would like to examine the mechanism of osseointegration. We randomly used 8 male and female house rabbit amd used diameter 5 mm height spiral shaped implants(Ostem, Korea) for animal use handled as a resorbable blast machined(RBM) surface and machined surface. 2group were formed and each group had RBM surface and machined surface implant or a simple bone cavity. After 3, 7, 14 and 28 days post surgery 2 objects were sacrificed from each group and histologic specimens were acquired. RT-PCR analysis was conducted and after H&E staining the extent of osseointegration was measured applying a histologic feature and histomorphometric analysis program. Quanitity one -4.41(Bio-Rad, USA) was used after scanning the PCR product image of the growth factors manifested in each group. According to the histomorphometric features the RBM, Machined surface group showed increased contact between bone and implant surface at 3, 7, 14 and 28 days after surgery. The BMP2 level increased in both experiment groups but remained unchanged in the contrast group. BMP4 levels stayed steady after the early post implantation period for RBM but showed decreased in the machined surface group and contrast group. The amount of contact between bone and implant surface increased with the passage of time. BMP2, BMP4 were expressed in both experimental group and contrast group. These growth factors play a role in osseointegration of implant.

Increased Osteoblast Adhesion Densities on High Surface Roughness and on High Density of Pores in NiTi Surfaces

  • Im, Yeon-Min;Gang, Dong-U;Kim, Yeon-Uk;Nam, Tae-Hyeon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.39.1-39.1
    • /
    • 2009
  • NiTi alloy is widely used innumerous biomedical applications (orthodontics, cardiovascular, orthopaedics, etc.) for its distinctive thermomechanical and mechanical properties such as shape memory effect, super elasticity, low elastic modulus and high damping capacity. However, NiTi alloy is still a controversial biomaterial because of its high Ni content which can trigger the risk of allergy and adverse reactions when Ni ion releases into the human body. In order to improve the corrosion resistance of the TiNi alloy and suppress the release of Ni ions, many surface modification techniques have been employed in previous literature such as thermal oxidation, laser surface treatment, sol-gel method, anodic oxidation and electrochemical methods. In this paper, the NiTi was electrochemically etched in various electrolytes to modify surface. The microstructure, element distribution, phase composition and roughness of the surface were investigatedby scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry(EDS), X-ray diffractometry (XRD) and atomic force microscopy (AFM). Systematic controlling of nano and submicron surface features was achieved by altered density of hydro fluidic acid in etchant solution. Nanoscale surface topography, such as, pore density, pore width, pore height, surface roughness and surface tension were extensively analyzed as systematical variables.Importantly, bone forming cell, osteoblast adhesion was increased in high density of hydro fluidic treated surface structures, i.e., in greater nanoscale surface roughness and in high surface areas through increasing pore densities.All results delineate the importance of surface topography parameter (pores) inNiTi to increase the biocompatibility of NiTi in identical chemistry which is crucial factor for determining biomaterials.

  • PDF

Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces

  • Li, Lin-Jie;Kim, So-Nam;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.235-240
    • /
    • 2016
  • PURPOSE. In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS. The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS. Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION. This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.

Influence of surface treatments on the shear bond strength between zirconia ceramic and zirconia veneering ceramics (지르코니아의 표면 처리에 따른 전장용 세라믹과의 전단결합강도)

  • Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.19-27
    • /
    • 2013
  • Purpose: The aim of this research was to evaluate the shear bond strength of different zirconia veneering ceramics with and without liner glass materials to yttria partially-stabilized tetragonal zirconia polycrystalline(Y-TZP). Methods: Five co mmercial zirconia veneering ceramics were used in this study, E-Max(EM), Creation ZI(CR), Cercon ceram kiss(CE), Triceram(TR) and Zirkonzahn ICE(ZI). All samples were prepared according to manufacturer's instructions. Experimental industrially manufactured Y-TZP ceramic blocks(diameter: 2.7 mm; height: 13.5 mm) were used in this study. Shear bond strength between zirconia ceramic coping and zirconia veneering ceramics were evaluated by the push-shear bond test. The fracture load data were analyzed using ANOVA and Scheffe's test(${\alpha}$=0.05). The fractured surfaces of zirconia core ceraimc and zirconia veneering ceramics were observed using a scanning electron microscope(SEM). Results: The mean shear bond strengths ranged from 20 MPa ($20.12{\pm}6.34$ MPa) to 66.6 MPa ($66.62{\pm}10.01$ MPa). The Triceram(TRG) showed the highest value and Creation ZI(CR) showed the lowest value. In all groups, Zirconia liner and glass material groups was significantly higher shear bond strength than without liner(P<0.05), with the exception of Cercon ceram kiss(CE)groups. Conclusion: Zirconia bonding materials may have the advantage of improved bond strength between zirconia ceramic core and veneering ceramics.

Wettability Evaluation of Resin on the Glass Fabric (유리섬유직물에 대한 수지의 젖음성 평가)

  • Han, Seung-Wook;Choi, Nak-Sam;Lee, Min-Soo;Ahn, Hung-Kun
    • Composites Research
    • /
    • v.24 no.2
    • /
    • pp.30-37
    • /
    • 2011
  • Analysis of wettability between epoxy resin and glass fabric was studied. The mixing ratios of epoxy resin and anhydride hardener were varied as 1:0.5, l:l and l:1.2. Catalyst content was fixed as 0.1wt% of the mixed resin. A curing analysis by differential scanning calorimeter(DSC) showed a possible impregnation of the mixed resin at the room temperature. An effective contact angle of the mixed epoxy resin drop onto the glass fabric being preset on a flat glass plate was measured as a function of time. The wet area of the epoxy resin drop was also measured. Behaviors of the contact angle, the droplet height, the neat wet area and the coefficient of wettability were used to evaluate the wettability of the epoxy resin onto the glass fabric. It was concluded that the equivalent ratio of 1: 1.2 was the most suitable for the wettability.