• Title/Summary/Keyword: Scan-based test

Search Result 210, Processing Time 0.03 seconds

DEVELOPMENT OF KASI SOLAR IMAGING SPECTROGRAPH (한국천문연구원 태양영상분광기 개발)

  • Kim, Y.H.;Moon, Y.J.;Cho, K.S.;Park, Y.D.;Choi, S.H.;Jang, B.H.;Kim, S.
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.51-59
    • /
    • 2006
  • We have successfully developed the KASI (Korea Astronomy and Space Science Institute) Solar Imaging Spectrograph (KSIS), which has been originally upgraded from the KASI solar spectrograph that was able to record solar spectra for a given slit region and to inspect the response function of narrow band filters. A prototype KSIS was developed in 2004 by using a scanning mirror in front of the spectrograph slit and a SBIG ST-8XE CCD camera. Its main disadvantage is that it took a long time (about 13 minutes) to scan a whole active region. In this work, we have upgraded the KSIS by installing a much faster Dalsa 1M15 CCD camera, which gives a data acquisition time of about 2.5 minutes. The software for KSIS was also improved for the new CCD camera on the basis of component-based development method. We have successfully made a test observation for a simple and small active region (AR10910) using the improved KSIS system. Our observations show that H-alpha images for several wavelengths have typical features in a sunspot as well as a H-alpha centerline image is quite similar to a BBSO H-alpha image, demonstrating the capability of the KSIS system.

Development of High-Speed Real-Time Signal Processing for 3D Surveillance Radar (3차원 탐색 레이더용 고속 실시간 신호처리기 개발)

  • Bae, Jun-Woo;Kim, Bong-Jae;Choi, Jae-Hung;Jeong, Lae-Hyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.737-747
    • /
    • 2013
  • A 3-D surveillance radar is a pulsed-doppler radar to provide various target information, such as range, doppler and angle by performing TWS. This paper introduces HW/SW architecture of radar signal processing board to process in real-time using high-speed multiple DSP(Digital Signal Processor) based on COTS. Moreover, we introduced a implemented algorithm consisted of clutter map creation/renewal, FIR(Finite Impulse Response) filter for rejection of zero velocity components, doppler filter, hybrid CFAR and finally presented computational burden of each algorithm by performing operational test using a beacon.

Design and Implementation of the Front part of an Agricultural Electric Vehicle based on Vacuum Forming using Computational Structural Analysis

  • Lee, Hun-Kee;Park, Myeong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.45-51
    • /
    • 2021
  • In this paper, we propose a 3D design method of the vacuum forming method of the front part to improve the lightness and production efficiency of agricultural electric vehicles. For agricultural electric vehicles, lightness and production efficiency are more important than the strength of materials for collision protection. In this paper, we propose a vacuum forming design method that can replace complex machining processes such as laser machining, bending, and painting. The main purpose of this research is to improve product stability, productivity and convenience through 3D design of the front part and development of vacuum forming mold technology. Research procedure follows the 3D modeling of the front part using CATIA, finite element analysis for the structural stability using ABAQUS, manufacturing prototype for the investigation of the dimensions using 3D scanner and actual driving test under agricultural electric vehicle usage environment. The results verifies the proposed 3D design method of the vacuum forming method and are expected to be widely used by agricultural workers through the simplification of the production process of agricultural electric vehicles.

Subcortical Ischemic Change as a Predictor of Driving Cessation in the Elderly

  • Jang, Mi;Hong, Chang Hyung;Kim, Hyun-Chung;Choi, Seong Hye;Seo, Sang Won;Kim, Seong Yoon;Na, Duk L.;Lee, Yunhwan;Chang, Ki Jung;Roh, Hyun Woong;Son, Sang Joon
    • Psychiatry investigation
    • /
    • v.15 no.12
    • /
    • pp.1162-1167
    • /
    • 2018
  • Objective Motor, perceptual, and cognitive functions are known to affect driving competence. Subcortical ischemic changes on brain magnetic resonance imaging (MRI) can reflect reduction in cognitive and motor performance. However, few studies have reported the relationship between subcortical ischemic changes and driving competence of the elderly. Thus, the objective of this study was to investigate the association between subcortical ischemic changes on MRI and driving abilities of the elderly. Methods Participants (n=540) were drawn from a nationwide, multicenter, hospital-based, longitudinal cohort. Each participant underwent MRI scan and interview for driving capacity categorized into 'now driving' and 'driving cessation (driven before, not driving now)'. Participants were divided into three groups (mild, n=389; moderate, n=116; and severe, n=35) depending on the degree of white matter hyperintensity (WMH) on MRI at baseline. Driving status was evaluated at follow-up. Statistical analyses were conducted using ${\chi}^2$ test, analysis of variance (ANOVA), structured equation model (SEM), and generalized estimating equation (GEE). Results In SEM, greater baseline degree of WMH was directly associated with driving cessation regardless of cognitive or motor dysfunction (${\beta}=-0.110$, p<0.001). In GEE models after controlling for age, sex, education, cognitive, and motor dysfunction, more severe change in the degree of WMH was associated with faster change from 'now driving' state to 'driving cessation' state over time in the elderly (${\beta}=-0.508$, p<0.001). Conclusion In both cross-sectional and longitudinal results, the degree of subcortical ischemic change on MRI might predict driving cessation in the elderly.

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kang, Seen-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.24-35
    • /
    • 2021
  • PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

Estimation of Appropriate Number of Radiologic Technologist Based on Analysis of Time Required for Computed Tomography (전산화단층촬영의 소요시간 분석에 기반한 방사선사의 적정인력 산정에 관한 연구)

  • Lee, Ki-Baek;Kim, Yung-Kyoon;Kim, Eun-Hye;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.213-223
    • /
    • 2022
  • Although the number of computed tomography(CT) is increasing every year, it is insufficient to establish appropriate workload calculation standards of radiologic technologist to provide optimal medical services to patients, such as patient safety management and infection management. The purpose of this study is to present guidelines for calculating the appropriate workload of radiologic technologist by analyzing the work flow of CT procedures and the time required for CT examination in major hospitals. As for the study subjects and methods, the appropriate process for each step of CT examination was investigated to systematically present the process and time required for the actual examination, and the CT procedure time of 104,105 adult patients and 465 pediatric patients under the age of 6 were analyzed. For the time required, data according to the use of contrast medium, procedure type, and adult/child were collected and compared. The test time of CT examination using contrast medium took about 13 minutes when one radiologic technologist worked and about 9 minutes when two radiologic technologists worked. The time required for the procedures were statistically significant depending on the presence or absence of contrast medium, multi-phase procedure, and patient age (considering pediatric patients). As a result, in order to thoroughly perform patient safety and infection management, the appropriate workload increased by about 40% when there were two radiologic technologists. The limit workload was an average of 32 people per day with one radiologic technologist per 15 minutes, and 48 people per day with two radiologic technologist per 10 minutes. This is a marginal workload, and in the case of procedures that require more time to acquire radiographic images, the interval between reservations should be widened.

Analysis of CT Image Quality Change according to Clinical Application Shielding Materials (임상 적용 차폐물질에 따른 선량 및 CT 화질 변화 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Among brain CT scan conditions including the lens, the tube voltage was changed to 80, 100, and 120 kVp and applied. The change in dose was analyzed using lead, lead goggles and barium sulfate silicon shielding materials, and the degree of influence of the shielding materials on image quality was compared and analyzed by applying the SNR, CNR, and SSIM index analysis methods. As a result, it was analyzed that although the dose was reduced by applying all shielding materials, the difference in dose reduction was not large (P > 0.05). In addition, as for the change in image quality due to the application of the shielding material, SNR and CNR were the highest when lead goggles were applied, and the structural similarity was measured to be the best as it was closest to the reference value of 1 in SSIM analysis. Therefore, based on the results of this study, it is thought that if more diverse shielding materials and clinical test results are derived and applied, it will be helpful for the clinical application criteria in the case of shielding utilization inspection.

How do imaging protocols affect the assessment of root-end fillings?

  • Fernanda Ferrari Esteves Torres;Reinhilde Jacobs;Mostafa EzEldeen;Karla de Faria-Vasconcelos;Juliane Maria Guerreiro-Tanomaru;Bernardo Camargo dos Santos;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.2.1-2.11
    • /
    • 2022
  • Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 ㎛. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results: All materials showed an increase in thickness from 5 to 10 and 20 ㎛ (p < 0.05). When evaluating the interface voids, materials were similar at 5 ㎛ (p > 0.05), while at 10 and 20 ㎛ Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 ㎛, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 ㎛. Conclusions: Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 ㎛.

Hypoxemia In Liver Cirrhosis And Intrapulmonary Shunt Determination Using Tc-99m-MAA Whole Body Scan (간경화 환자에서의 저산소혈증과 Tc-99m-MAA 주사를 이용한 폐내단락 측정)

  • Lee, Kye-Young;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.504-512
    • /
    • 1994
  • Background: It is well known that severe hypoxemia is often associated with liver cirrhosis without preexisting cardiac or pulmonary diseases. Pulmonary vascular impairments, more specifically, intrapulmonary shunting have been considered as a major mechanism. Intrapulmonary shunting arises from pulmonary vascular dilatation at the precapillary level or direct arteriovenous communication and has relationship with the characteristic skin findings of spider angioma. However, these results are mainly from Western countries where alcoholic and primary biliary cirrhosis are dominant cuases of cirrhosis. It is uncertain that the same is true in viral hepatitiss associated liver cirrhosis, which is dominant causes of liver cirrhosis in Korea. We investigated the incidences of hypoxemia and orthodeoxia in Korean cirrhotic patients dominantly composed of postnecrotic cirrhosis and the significance of intrapulmonary shunting as the suggested mechanism of hypoxemia, Method: We performed the arterial blood gas analysis separately both at the supine and errect position in 48 stable cirrhotic patients without the evidences of severe complications such as ascites, variceal bleeding, and hepatic coma. According to the results of arterial blood gas analysis, all patients were divided into hypoxemic and normoxemic group. In each group, pulmonary function test and Tc-99m-MAA whole body scan were performed. The shunting fraction was calculated based on the fact that the sum of cerebral and bilateral renal blood flow is 32% of the systemic blood flow. Results: The hypoxemia of $PaO_2$ less than 80 mmHg was observed in 9 patients(18.8%) and Orthodeoxia more than 10 mmHg was observed in 8 patients(16.7%). But there was no patient with significant hypoxemia of $PaO_2$ less than 60 mmHg. $PaO_2$ was significantly decreased in the patients with spider angioma than the pathients without spider angioma and showed no correlation with the serologic type and severities of liver function test findings. Any parameters of pulmonary function test did not demonstrate the difference between normoxemic and hypoxemic group. But hypoxemic group showed significantly increased shunt fraction of $11.4{\pm}4.1%$ than normoxemic group of $4.1{\pm}2.0%$ (p<0.05). Conclusions: Hypoxemia is not infrequently observed complication in liver cirrhosis and intrapulmonary shunting is suggested to p1ay a major ro1e in the development of hypxemia. But there was no great likelihood of clinically significant hypoxemia in our domestic cirrhotic patients predominantly composed of postnecrotic type.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF