• 제목/요약/키워드: Scan technique

검색결과 594건 처리시간 0.025초

20대 빈약 유방 여성용 몰드 브래지어 컵의 형태 설계 방법 (Shape Design Method of Mold Brassiere Cup for Small-breasted Women in their Twenties)

  • 이현영
    • 한국의류산업학회지
    • /
    • 제17권6호
    • /
    • pp.988-995
    • /
    • 2015
  • Gaps between the upper edges of brassiere mold cups and the breasts are one of the most serious issues in realizing comfort wearing of commercial brassieres for small-breasted women. The surplus ease amounts causing the fit problem were measured from 3D wearing images of the small-breasted women's brassieres. The effect after the removing the surplus ease amounts from the upper edge of mold cup was approved by subjective wearing evaluation. Since the volume distribution of mold cup can also affect the wearing sensation of brassiere, the subjective wearing sensation was compared for two brassieres of different volume distributions, VL, of which volume was concentrated at the lower cup, and VC, which has the thickest part at the nipple. As the results, the suitable sensation for cup volume and the natural wearing silhouette could be accomplished by removing the surplus ease amounts from the upper edge of mold cup to reduce the gaps between brassieres and the breasts, which could be accomplished through an approach reducing the volume near the upper edge of mold brassiere cup and making the volume concentrated at the lower cup. These works provide a useful information on the design of the brassiere mold cups for small-breasted women. Moreover, modeling methods of 3D scan data and 3D printing technique for making more accurate mold cases used in this research can be helpful to develop and evaluate clothing products in future.

비직교성 전산화단층촬영에서 뇌정위수술용 좌표계를 이용한 표적위치 결정 (Determination of Target Position with BRW Stereoatic Frame in non-orthogonal CT scans)

  • Park, Tae-Jin;Kim, Ok-Bae;Son, Eun-Ik
    • 한국의학물리학회지:의학물리
    • /
    • 제3권1호
    • /
    • pp.53-62
    • /
    • 1992
  • 최근 두개부 종양의 방사성물질의 자입과 방사선입체조사에 의한 뇌수술이 개발되어 의료계 에 많은 관심을 끌고 있다. 또한 방사선수술등은 비관혈적인 체외조사이므로 뇌정위수술용 좌표계의 전산화단층촬영을 이용한 표적중심결정이 매우 중요하다. 현재 알려진 방법은 뇌정위수술용좌표계의 전산화단층찰영에 대한 직교성하에서 비교적 정확하게 표적의 위치를 결정하게 되나, 임상현장에서 직교성유지는 실제 어려운 실정이다. 이에 필자들은 임의의 비직교성 스켄하에서 정확한 표적좌표를 얻기위한 알고리즘을 사용하였으며, 표적오차는 평균 0.02$\pm$0.3mm를 보였다.

  • PDF

71세 남자에서 발생한 후방십자인대 대퇴골 부착부 견열 골절 - 1례 보고 - (Femoral Bony Avulsion Fracture of the Posterior Cruciate Ligament in a Seventy one Year Old Man - A Case Report -)

  • 이영현;안길영;남일현;문기혁;김기철;이채경;이상충
    • 대한관절경학회지
    • /
    • 제14권2호
    • /
    • pp.128-130
    • /
    • 2010
  • 후방십자인대의 대퇴골 견열 골절은 성인에서 매우 드문 손상이다. 과거 슬관절 손상으로 인해 관절 운동의 부분적 제한이 있던 71세 남자 환자가 약 2미터 높이에서 떨어지는 사고로 내원하였다. 촬영한 컴퓨터 단층촬영 및 자기공명영상검사에서 후방십자인대 대퇴골 부착부 견열 골절을 확인하였다. 관절경 시술 하에 두개의 강선으로 대퇴 내과를 통하여 고정하였다. 술 후 1년째 강선 제거술 및 2차 관절경 검사로 골절 부위의 유합을 확인 하였기에 이를 문헌고찰과 함께 보고하는 바이다.

  • PDF

스테가노그라피 기법이 적용된 QR코드 이미지 기반의 키 교환 프로토콜 (A Key Exchange Protocol based on the Steganography with the QR code)

  • 이길제;윤은준;유기영
    • 전자공학회논문지
    • /
    • 제50권6호
    • /
    • pp.173-179
    • /
    • 2013
  • 기존의 키 교환 프로토콜은 암호학적 방법들을 사용하여 비밀 키를 전달해왔지만, 공격자들로 하여금 다양한 공격을 받아왔었다. 이를 해결하기 위해 본 논문에서는 스테가노그라피 기법을 이용한 키 교환 프로토콜을 제안하였다. 스테가노그라피 기법은 이미지, 문서, 동영상, MP3 파일 등에 비밀 정보를 숨겨 공격자가 비밀 정보가 전달되고 있다는 것을 모르게 하는 방법으로 비밀 키를 공격자의 의심을 받지 않고 효율적으로 전달할 수 있다. 또한, 최근에 많이 사용되고 있는 2차원 바코드인 QR코드를 비밀 키가 삽입되는 이미지로 사용하여 공격자가 QR 코드를 스캔하여도 QR코드 생성 시 사용되었던 URL로 접속하게 되며 QR 코드에 비밀 키가 삽입된 것을 인식하지 못하게 한다. 실험을 통해서 기존의 스테가노그라피에서 사용되었던 이미지와 QR코드의 이미지의 변형 정도를 측정하여 QR 코드 이미지를 사용했을 때 효율성을 검증해본다.

이하선 심부엽에 발생한 거대 혼합종(Giant Pleomorphic Adenoma) 1예 (A Case of Giant Pleomorphic Adenoma Arising in the Deep Lobe of the Parotid Gland)

  • 윤종호;장항석;정웅윤;박정수
    • 대한두경부종양학회지
    • /
    • 제14권1호
    • /
    • pp.103-106
    • /
    • 1998
  • Pleomorphic adenoma is the most common tumor in the parotid gland and a parotidectomy with preservation of the facial nerve is a widely accepted treatment. With the advanced imaging methods such as CT scan or MRI and the developed surgical technique, the incidence of complications in parotid surgery declined considerably. However, when the tumor forms a huge mass after a prolonged period, surgeons tend to hesitate surgical treatment regarding the possibility of facial nerve injury and incomplete resection due to a malignant transformation of the tumor. And this is more likely when the huge tumor arised in the deep lobe of the parotid gland. We present a case of 39-year old man with a giant pleomorphic adenoma arising in the deep lobe of the parotid gland who was treated successfully by total parotidectomy without any complications. The size and weight of the tumor were 20x15x15cm and 1,100gm, respectively. In our experience, because pleomorphic adenoma is well encapsulated and not invasive to the adjacent tissue, even a giant pleomorphic adenoma arising in the deep lobe of the parotid gland can be treated by careful surgical resection with the preservation of the facial nerve.

  • PDF

The Efficacy of Bioabsorbable Mesh as an Internal Splint in Primary Septoplasty

  • Kim, Jee Nam;Choi, Hyun Gon;Kim, Soon Heum;Park, Hyung Jun;Shin, Dong Hyeok;Jo, Dong In;Kim, Cheol Keun;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.561-564
    • /
    • 2012
  • Nasal bone fractures are often accompanied by septal fractures or deformity. Posttraumatic nasal deformity is usually caused by septal fractures. Submucosal resection and septoplasty are commonly used surgical techniques for the correction of septal deviation. However, septal perforation or saddle nose deformity is a known complication of submucosal resection. Hence, we chose to perform septoplasty, which is a less invasive procedure, as the primary treatment for nasal bone fractures accompanied by septal fractures. During septoplasty, we used a bioabsorbable mesh as an internal splint. We used the endonasal approach and inserted the mesh bilaterally between the mucoperichondrial flap and the septal cartilage. The treatment outcomes were evaluated by computed tomography (CT) and the nasal obstruction symptom evaluation (NOSE) scale. The CT scans demonstrated a significant improvement in the septal deviation postoperatively. The symptomatic improvement rated by the NOSE scale was greater at 1 month and 6 months after surgery compared to the preoperative status. There were no cases of extrusion or infection of the implant. In cases of moderate or severe septal deviation without dislocation from the vomerine groove on the CT scan, our technique should be considered one of the treatments of choice.

Short-term Outcomes of Aortic Wrapping for Mild to Moderate Ascending Aorta Dilatation in Patients Undergoing Cardiac Surgery

  • Park, Ji-Young;Shin, Je-Kyoun;Chung, Jin-Woo;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • 제45권3호
    • /
    • pp.148-154
    • /
    • 2012
  • Background: The adequate management of mild to moderate dilatation of the ascending aorta during cardiac operations remains controversial. In this study, we present the short-term outcomes of 90 patients undergoing ascending aortic wrapping with a Dacron graft during other cardiac operations. Materials and Methods: From March 2008 to January 2011, 90 consecutive patients underwent treatment for ascending aortic aneurysm using the external wrapping technique during the concomitant procedure. The study group consisted of 49 male and 41 female patients with a mean age of $58.7{\pm}13$years. The primary cardiac surgical procedures were coronary artery bypass grafting (CABG) in 3, aortic valve replacement in 2, and aortic valvuloplasty in 85 patients (isolated in 62 and combined with CABG or mitral valvuloplasty in 23). The ascending aorta diameter was measured using a computed tomography scan within 4 weeks after surgery, and was compared with the preoperative value. Results: The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within a month after surgery from $46.4{\pm}4.3$ mm to $33.0{\pm}3.5$ mm (p<0.05). There was no early mortality or major surgical complication. During the mean follow-up period of $15.4{\pm}5.2$ months, there was only one late death caused by septic multiorgan failure. Conclusion: Dacron wrapping of the ascending aorta offers excellent results with very low mortality and morbidity, and it can be regarded as a safe and effective method for the treatment of moderately dilated ascending aorta in selected patients.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

자기공명영상장치에서 전자파흡수율 분석 (Analysis of Specific Absorption Rate in Magnetic Resonance Imaging)

  • 한재복;홍성훈;최남길;성호진
    • 한국콘텐츠학회논문지
    • /
    • 제13권2호
    • /
    • pp.308-313
    • /
    • 2013
  • 본 연구는 자기공명영상장치의 특성변수인 숙임각(flip angle), 반복시간(repetition time, TR), 에코시간(echo time, TE)을 사용하여 전자파흡수율(specific absorption rate, SAR)을 알아보고자 하였다. 연구대상은 체중 10 kg부터 90 kg까지를 대상으로 하여 동일한 검사기법을 적용하였고, 매개변수의 변화에 따른 평균 SAR 및 peak SAR 값을 측정하였다. 체중에 따른 SAR는 TE에서 변화는 없지만 숙임각이 커지고 TR이 짧을수록 증가하였다. SAR 값은 두부 허용 기준치 범위에 포함이 되었고 분절별 체중에 따른 영상의 신호 대 잡음비(signal to noise ratio, SNR)는 체중이 증가함에 따라 SNR은 증가하지는 않았다. 본 결과를 바탕으로 적절한 특성변수를 사용하여 다양한 대조도와 SNR을 얻어 진단의 가치를 높일 수 있을 것이다.

다차원 스트림 데이터의 연관 규칙 탐사 기법 (Mining Association Rules in Multidimensional Stream Data)

  • 김대인;박준;김홍기;황부현
    • 정보처리학회논문지D
    • /
    • 제13D권6호
    • /
    • pp.765-774
    • /
    • 2006
  • 연관 규칙 탐사는 데이터베이스를 분석하여 잠재되어 있는 지식을 발견하기 위한 기법으로 스트림 데이터 시스템에서 연관 규칙 탐사에 대한 연구가 활발하게 진행되고 있다. 그러나 대부분의 연구들은 센서에서 수집되는 단일 스트림 데이터에 관한 것이며 다차원 스트림 데이터간의 연관 정보는 간과하고 있다. 본 논문에서는 다차원 스트림 데이터간의 연관 규칙을 탐사할 수 있는 AR-MS 방법을 제안한다. AR-MS 방법은 한 번의 데이터 스캔으로 연관 규칙 탐사에 필요한 요약 정보를 구축함으로써 스트림 데이터의 특성을 반영하며, 자주 발생하지는 않지만 특정 이벤트와 빈번하게 발생하는 의미 있는 희소 항목 집합에 대한 연관 규칙을 탐사할 수 있다. 또한 AR-MS 방법은 구축된 요약 정보를 사용하여 다차원 스트림 데이터간의 최대 빈발 항목 집합에 대한 연관 규칙도 탐사한다. 그리고 다양한 실험을 통하여 제안하는 방법이 기존의 방법들에 비하여 우수함을 확인하였다.