• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.028 seconds

A Study on the Frequency of Occurrence of the Aortic Dissection using CT (CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰)

  • Dong, Kyung-Rae;Choi, Sung-Kwan;Jang, Young-Ill;Ro, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • Purpose: Aortic Dissection is very dangerous, prognostic disease, which the bloodstream flow out of the true lumen of the aorta by the bursting of aortic intima resulting in a rapid dissociation of inner and outer layer from the media. It is difficult to diagnose aortic dissection clinically by normal X-ray. This study was to investigate the occurrence frequency by age and number of patients who are identified to be aortic dissection by CT (Computed Tomography) scan. Materials and methods: We investigated the trend of yearly fluctuation, gender, age, and department of clinical research of the 112 patients who conducted CT scan in C- University Hospital for two years from January 2005 to December 2006. The MIP and SSD which reconstructed CT image and the VRT image were obtained for the accurate observation. The result was investigated by comparing normal X-ray and CT scan. Results and Conclusion: 1. The yearly check of 112 patients conducted CT scan showed 37 people (41.9%) in 2005, and it was increased to 65 (58.1%) in 2006 by 1.4 times. 2. The gender distribution of patients given a CT scan showed 45 males (40.1%), and female 67 (59.9 %). The aortic dissection patients were 9 (20%) out of 45 males, 21 (31.3%) out of 67 females and women were 1.6 times more than men. Women are also 1.5 times more than men in the number of examinee. 3. The age distribution of patient's who conducted CT scan revealed that there was no patient under 30 years old while 88.3% of all patients were through 41 to 80 years old. The higher the age was, the higher the occurrence of aortic dissection was. The difference in the occurrence frequency of age was statistically significant (p<0.01). 4. The departments that requested CT scan were the emergency department 46 (41.1%), circulatory internal medicine 37 (33.0%), chest surgery 13 (11.6%), and others 6 (14.3%). The combined ratio of emergency medicine and circulatory internal medicine was 74.1% of all. The results show that the aortic dissection is a very dangerous disease whose patients visit mainly via the emergency room. 5. The aortic dissection patients had normal X-ray readings in 22 (73.3%) out of 30, and only 8 (26.7 percent) are abnormal in the X-ray diagnosis. Therefore, the CT scan needs to be enforced in order to assess accurately the disease of aortic dissection.

  • PDF

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF

The Effect of Annealing on Corrosion Behavior of CoCrTa/CrNi Magnetic Recording Media (CoCrTa/CrNi 자기기록매체의 열처리에 따른 부식거동 변화)

  • 우준형;남인탁
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.210-216
    • /
    • 1999
  • The objective of this paper is to investigate corrosion behaviors of CoCrTa/CrNi thin film and post heat-treatment effect. An electron beam evaporator was used for films deposition. After evaporation, post heat-treatment was carried out under $5.0{\times}10^3$ Torr vacuum condition. Annealing temperature and time were 400 $^{\circ}C$ and 30 min, respectively. To understand the effect of annealing on corrosion behavior of CoCrTa/CrNi, potentiodynamic polarization technique and accelerated corrosion chamber test were undertaken. Corrosion potential is higher for the annealed samples (CoCrTa 400$\AA$/CrNi 1000$\AA$) than for as-deposited one. This is attributed to an enrichment of Cr in the surface layer of the thinfilm resulting in a more corrosion resistant material.

  • PDF

SAR Payload Technology for Next Generation Satellite (차세대 위성용 SAR 탑재체 기술)

  • Won, Young-Jin;Yoon, Jae-Cheol;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.131-141
    • /
    • 2014
  • Synthetic Aperture Radar (SAR) is a powerful and well established microwave remote sensing technique which enables high resolution measurements of the Earth surface independent of weather conditions and sunlight illumination. In this study, this paper first summarizes the basic SAR theory and the history of the SAR satellites. The second part of this paper gives an overview of new technologies for future SAR systems. New innovative concepts and technologies for SAR satellites will be digital beamforming, High Resolution Wide Swath (HRWS), Waveform Encoding, Terrain Observation by Progressive Scan (TOPS), and so on. These technologies will play an important role for future spaceborne SAR satellites.

A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid

  • Yu, Joonhee;Kim, Tae Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.274-281
    • /
    • 2017
  • This paper describes the simple fabrication of an electrode modified with electrochemically reduced graphene oxide (ERGO) for the simultaneous electrocatalytic detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA). ERGO was formed on a glassy carbon (GC) electrode by the reduction of graphene oxide (GO) using linear sweep voltammetry. The ERGO/GC electrode was formed by subjecting a GO solution ($1mg\;mL^{-1}$ in 0.25 M NaCl) to a linear scan from 0 V to -1.4 V at a scan rate of $20mVs^{-1}$. The ERGO/GC electrode was characterized by Raman spectroscopy, Fourier transform infrared spectroscopy, contact angle measurements, electrochemical impedance spectroscopy, and cyclic voltammetry. The electrochemical performance of the ERGO/GC electrode with respect to the detection of DA, AA, and UA in 0.1 M PBS (pH 7.4) was investigated by differential pulse voltammetry (DPV) and amperometry. The ERGO/GC electrode exhibited three well-separated voltammetric peaks and increased oxidation currents during the DPV measurements, thus allowing for the simultaneous and individual detection of DA, AA, and UA. The detection limits for DA, AA, and UA were found to be 0.46, 77, and $0.31{\mu}M$ respectively, using the amperometric i-t curve technique, with the S/N ratio being 3.

Design of Efficient Hacking Prevention Systems Using a Smart Card (스마트카드 기반의 효율적인 해킹 방지 시스템 설계)

  • 황선태;박종선
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.2
    • /
    • pp.179-190
    • /
    • 2004
  • This paper describes the design of hacking prevention systems using a smart card. It consists of two parts, i.e., PC authentication and Keyboard-buffer hacking prevention. PC authentication function is a procedure to handle the access control to the target PC. The card's serial number is used for PIN(Personal Identification Number) and is converted into hash-code by SHA-1 hash-function to verify the valid users. The Keyboard-buffer hacking prevention function converts the scan codes into the encoded forms using RSA algorithm on the Java Card, and puts them into the keyboard-buffer to protect from illegal hacking. The encoded information in the buffer is again decoded by the RSA algorithm and displayed on the screen. in this paper, we use RSA_PKCS#1 algorithm for encoding and decoding. The reason using RSA technique instead of DES or Triple-DES is for the expansion to multi-functions in the future on PKI. Moreover, in the ubiquitous computing environment, this smart card security system can be used to protect the private information from the illegal attack in any computing device anywhere. Therefore, our security system can protect PC user's information more efficiently and guarantee a legal PC access authority against any illegal attack in a very convenient way.

  • PDF

Restoration of Landsat ETM+ SLC-off Gaps Using SPOT Image (SPOT 영상을 이용한 Landsat-7의 SLC-off 영상 복원)

  • Kim Hye-Jin;Yu Ki-Yun;Kim Yong-Il
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.229-234
    • /
    • 2006
  • On May 31, 2003. Landsat 7 experienced an anomaly causing the Scan Line Corrector(SLC) to stop functioning normally. The SLC-off causes individual scan lines to alternately overlap and then leave large gaps at the edge of the Image. A many scientists with ongoing experience using ETM+ data evaluated the scientific usability and validity of Landsat 7 products containing the SLC anomaly The best reference scene for gap-filling is the other SLC-on Landsat scene that provide same resolution, few changes, and similar data acquisition. But receiving of Landsat imagery is not stable in Korea. So SPOT image can be another alternative solution because it is a steady-state multispectral satellite image as Landsat image. In this study, we filled the SLC-off gap s of 2, 3, 4 bands using SPOT image by a local regression technique, and assigned the optimum spectral value to gaps of 1, 5, 7 bands based on a spectral adjacency. Through this process, we could restore Landsat SLC-off image and evaluated the accuracy of the results.

  • PDF

Dislocation Density Estimation and mosaic Model for GaN/SiC(0001) by High Resolution x-ray Diffraction

  • Yang, Quankui;Li, Aizhen
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.43-46
    • /
    • 1997
  • High resolution x-ray diffraction and two dimensional triple axis mapping were used to characterize a group of GaN layers of about 1.1$\mu$m grown by direct current plasma molecular beam epitaxy technique on 6H-SiC(0001). A FWHM of 11.9 arcmins for an $\omega$ scan and 1.2 arcmins for an $\omega$/2$\theta$ scan were observed. A careful study of the rocking curves showed there were some large mosaics in the GaN layer and a tilt of $0.029^{\circ}$ between the GaN layer and the SIC substrate was detected. The two dimensional triple axis mapping showed that the GaN mosaica were disoriented in the (0001) plane but rather uniformed in direction perpendicular to the plane. A mosaics were disoriented in the (0001) plane but rather uniformed in direction perpendicular to the plane. A mosaic model was deduced to explain the phenomenon and the dislocation density was estimated to be about~$10^9\;\textrm{cm}^{-2}$ acc ding to the model.

  • PDF

Characteristics of Nanolithography Process on Polymer Thin-film using Near-field Scanning Optical Microscope (근접장현미경을 이용한 폴리머박막 나노리쏘그라피 공정의 특성분석)

  • 권상진;김필규;장원석;정성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.590-595
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a positive photoresist using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture( $P_{in}$ ), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}$ =1.2$\mu$W and V=12$\mu$m/. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage using azopolymer is discussed at the end.

  • PDF

Effect of the Laser Beam Size on the Cure Properties of a Photopolymer in Stereolithography

  • Sim, Jae-Hyung;Lee, Eun-Dok;Kweon, Hyeog-Jun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.4
    • /
    • pp.50-55
    • /
    • 2007
  • Stereolithography (SLA) is a technique using a laser beam to cure a photopolymer liquid resin with three-dimensional computer-aided design (CAD) data, The accuracy of the prototype, the build time, and the cured properties of the resins are controlled by the SLA process parameters such as the size of the laser beam, scan velocity, hatch spacing, and layer thickness, In particular, the size of the laser beam is the most important parameter in SLA, This study investigated the curing properties of photopolymers as a function of the laser beam size, The cure width and depth were measured either on a single cure line or at a single cure layer for various hatch spacings and laser beam sizes, The cure depth ranged from 0.23 to 0.34 mm and was directly proportional to the beam radius, whereas the cure width ranged from 0.42 to 1.07 mm and was inversely proportional to the beam radius, The resulting surface roughness ranged from 1.12 to $2.23{\mu}m$ for a ratio of hatch spacing to beam radius in the range 0.5-2.0 at a beam radius of 0.17 mm and a scan velocity of 125 mm/sec.