• 제목/요약/키워드: Scan equipments

검색결과 24건 처리시간 0.021초

Side Scan Sonar 영상표현에 관한 연구 (A Study on The Image Expression of Side Scan Sonar)

  • 장원실;윤기한;김영일
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.152-153
    • /
    • 2005
  • Side scan sonar System occupies an important position as one of marine survey equipments. The purpose of this research is to express sonar' scan images in underwater and compare with the measured size, shape and the quality of the material. Also we confirm the effectiveness of obtained images using the Side scan sonar.

  • PDF

다중 디지털 사진을 이용한 3차원 이미지 모델 생성 (Generation of 3 Dimensional Image Model from Multiple Digital Photographs)

  • 정태은;석정민;신효철;류재평
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1634-1637
    • /
    • 2003
  • Any given object on the motor-driven turntable is pictured from 8 to 72 different views with a digital camera. 3D shape reconstruction is performed with the integrated software called by Scanware from these multiple digital photographs. There are several steps such as configuration, calibration, capturing, segmentation, shape creation, texturing and merging process during the shape reconstruction process. 3D geometry data can be exported to cad data such as Autocad input file. Also 3D image model is generated from 3D geometry and texture data, and is used to advertise the model in the internet environment. Consumers can see the object realistically from wanted views by rotating or zooming in the internet browsers with Scanbull spx plug-in. The spx format allows a compact saving of 3D objects to handle or download. There are many types of scan equipments such as laser scanners and photogrammetric scanners. Line or point scan methods by laser can generate precise 3D geometry but cannot obtain color textures in general. Reversely, 3D image modeling with photogrammetry can generate not only geometries but also textures from associated polygons. We got various 3D image models and introduced the process of getting 3D image model of an internet-connected watchdog robot.

  • PDF

원전 탄소강 배관의 액적충돌침식 손상에 대한 B-Scan 검사 및 수치해석적 분석 (A Study on the Thermal Hydraulic Analysis and B-Scan Inspection for LDIE Degradation of Carbon Steel Piping in a Nuclear Plant)

  • 황경모;이대영
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.218-224
    • /
    • 2012
  • Liquid droplet impingement erosion (LDIE) known to be generated in aircraft and turbine blades is recently appeared in nuclear piping. UT thickness measurements with both A-scan and B-scan UT inspection equipments were performed for a component estimated as susceptible to LDIE in feedwater heater vent system. The thickness data measured with B-Scan equipment were compared with those of A-Scan. Thermal hydraulic analysis based on ANSYS FLUENT code was performed to analyze the behavior of liquid droplets inside piping. The wall thinning rate and residual lifetime based on both existing Sanchez-Caldera equation and measuring data were also calculated to identify the applicability of the existing equation to the LDIE management of nuclear piping. Because Sanchez-Caldera equation do not consider the feature of magnetite formed inside piping, droplet size, colliding frequency, the development of new evaluation method urgently needs to manage the pipe wall thinning caused by LDIE.

A-scan 방식을 응용한 초음파 비파괴 검사 장치 (An Ultrasonic NDT System using Modified A-scan Method)

  • 김건;서호선;차일환
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1985년도 학술발표회 논문집
    • /
    • pp.47-49
    • /
    • 1985
  • In most of ultrasonic NDT(Non-Destructive Testing) equipments using A-scan display technic, it is one of the inconveniences that the user must be proficient in reading the displayed signals for the accurate decisions. In this study, a simple microprocessorized NDT machine for the flaw detection was developed. The operation of system is based on the conventional NDT system. The microprocessor detects the time delay between transmitted pulse and echos by counter-measure method. Then according to the scanning position, the location of flaw orthe other side of testing object is plotted on the CRT. The main advantages of the developed system are simplicity in handling, recording capability of measured data, and low cost.

  • PDF

췌장암 Dual Time Point PET/CT 검사에서 Scan Position Change의 유용성 평가 (Usefulness of Scan Position Change on Dual Time Point PET-CT in Pancreas Cancer)

  • 장보석;김재호
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.299-305
    • /
    • 2016
  • 의료장비와 기술의 발달에도 불구하고 췌장암만 유일하게 기타 암질환과 비교하면 오진률이 높고 생존률이 낮은 질환이다. 따라서 췌장암은 조기 발견만이 생존율을 높일 수 있는 유일한 방법이며 췌장암의 정확한 위치를 찾는 것이 중요하다. Dual Point PET/CT 검사를 이용해서 췌장암의 조기 발견을 위한 최적의 Scan method를 제안하였다. PET/CT 검사의 Supine position에서 놓칠 수 있는 해부학적 영역을 환자의 position을 $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$ $75^{\circ}$ 변화에 따른 영상의 특징 및 유효성을 분석하였다. 그 결과 $90^{\circ}$ lateral recumbent position Scan에서 Pancreas tail 판별의 유용성을 발견하였다. Dual Point PET/CT 검사에서 상복부 특히 해부학적 구조상 췌장처럼 인접 장기와 중첩이 있는 경우, 췌장암이 의심될 때 PET/CT 지연검사에서 환자에게 충분한 수분섭취를 한 후 환자의 Position을 테이블과 수직 상태로 돌려 Lt 또는 Rt lateral Recumbent position 상태에서 PET/CT Scan을 시행하므로 위장, 간, 담낭 십이지장, 췌장 등의 장기를 이격시켜 해부학적 판별에 이점을 주는 검사방법 (JJ-Projection: lateral recumbent position scan)을 개발하였다. ROC curve 분석에서 JJ-Projection방법이 기존의 Supine scan 방식에서 얻은 영상보다 민감도가 95.2% 나타났다. 이것은 기존의 검사방식과 비교해볼 때 4.6 % 증가 하였다. 특이도는 87.5%로 6.9% 증가하였다. 조직검사로 생물학적 암으로 확정된 결과치와 비교해 볼 때 정확도는 94.1%로 기존 방식 86%에 비해 8.41 % 증가하였다. 그러므로 Dual Time Point PET/CT를 이용한 췌장암 판별 검사를 할 때 Delay scan에서 lateral recumbent position로 변경해서 Scan 하는 것이 기존의 일반적인 방법인 Supine position Scan보다 췌장암 조기 판별에 유용한 정보를 줄 수 있을 것으로 사료된다.

스캔라인 알고리즘을 이용한 대화력전 임기표적의 실시간 영역 결정 (Real-time Processing for Target of Opportunity Positioning of Counter-fire with Scan-line Algorithm)

  • 전기윤
    • 한국군사과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.148-151
    • /
    • 2007
  • The CF(Counter-fire) is neutralizing enemy's all command control systems and fire support elements. It will weaken a battle continuous ability and an intension to fight. At the beginning of the CF is obtaining locations of targets using various detection assets. CF command center processes acquired target information and send it to attacking equipments. The targets are classified into two classes, preplanned target and target of opportunity The target of opportunity is potential threaten, so it needs to take a immediate and exact process for determining location of target of opportunity. This paper proposes the real-time processing algorithm for offensive weapons to strike target of opportunity, and presents the result of its performance.

컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구 (A study on Computer-controlled Ultrasonic Scanning Device)

  • 허형;박치승;홍순신;박종현
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출 (Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method)

  • 윤중혁;김흥근;최종우;전태원;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰 (The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT)

  • 김지현;박훈희;이주영;남궁식;손현수;박상륜
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.15-24
    • /
    • 2013
  • SPECT/CT의 수요가 늘면서 CT에 따른 복합적 진단정보에 대한 관심이 대두되고 있으며, 그 잠재적 성능가치에 대한 연구가 다양하게 진행 중이다. 하지만 그에 따른 CT 피폭 저감에 대한 연구는 미비한 실정이다. 그러므로 본 연구에서는 상 하지(extremity) 뼈 SPECT/CT 검사 시 평판형(flat-panel) CT에서의 피폭저감 영향에 대해 고찰하는데 목적을 두었다. 상 하지 뼈 SPECT/CT 검사 시 평판형과 나선형(helical) CT 간의 선량 조건에 따른 영상의 질, 피폭선량 비교를 위해 BrightView XCT (Philips Healthcare, Cleveland, USA)와 Briliance 16 CT (Philips, Healthcare, Cleveland, USA)를 적용하였다. AAPM CT phantom을 대상으로 노이즈(noise), 공간 분해능(spatial resolution)을 평가하였으며, 촬영 조건은 관전압 120 kVp로 고정하고, 관전류량(mAs)는 평판형 CT의 상 하지용 촬영 조건인 20, 30, 40, 50, 60, 70, 80 mA를 기준으로 산출된 mAs를 두 장비에 동일 적용하였다. 각 조건별 동일 촬영거리 내에서 DLP (dose-length product)값을 산출하였다. 또한 CT의 조건변화에 따라 SPECT 영상에 미치는 영향을 확인하기 위해 NEMA IEC body phantom으로 영상을 획득하고 %contrast를 확인하였다. 산출된 정보는 SPSS ver.18로 기술통계 분석 하였다. AAPM phantom에서는 mAs의 증가에 따라 노이즈는 감소하였고, 평판형 CT가 나선형 CT보다 노이즈가 낮았으며, 그 차이는 저선량의 조건일수록 증가하였다. 분해능 평가에서 두 장비 모두 0.75 mm까지 육안으로 식별 가능하였고, 평판형 CT의 경우 선량조건(mA)의 증가에 따라 DLP값이 54-216 mGy cm까지 증가하였으며, 나선형 CT의 경우 177-709 mGy cm로 증가하였다. NEMA IEC body phantom에서는 CT 촬영 조건 변화에 따른 동일한 크기의 구(sphere)에서 측정한 결과 %contrast는 일정한 값을 유지하였다. 동일한 조건을 적용한 평판형과 나선형 CT 간의 선량 조건 변화에 따른 영상의 질은 큰 차이를 보이지 않았으며, 충분한 피폭저감의 효과를 얻을 수 있었다. 또한 SPECT 영상의 %contrast 분석을 통해 영상의 질이 유지되는 것을 확인하였다. 그러므로 촬영범위가 넓지 않고 고분해능을 요구하는 상 하지 뼈 SPECT/CT 검사에서 평판형 CT를 적용하는 것이, 나선형 CT에 비해 낮은 선량조건을 적용함에도 불구하고 유사한 영상의 질을 기대할 수 있다. 또한 이를 통해 실제 임상에서 불필요한 피폭선량 저감에 도움이 되리라 사료된다.

  • PDF

병원규모별 소아 두부 CT 검사 선량지표 분석 평가 (Analysis and Evaluation of Computed Tomography Dose Index (CTDI) of Pediatric Brain by Hospital Size)

  • 김현진;이효영;임인철
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.503-510
    • /
    • 2016
  • 소아는 방사선 감수성이 어른에 비해 높고 몸의 크기가 작아 어른과 같은 양의 방사선에 노출 되더라도 유효선량은 어른에 비해 더 높기 때문에 불필요한 피폭 방사선량을 줄이는 것이 매우 중요하다. 따라서 본 연구에서는 소아 두부 CT 검사에 있어서 피폭 방사선량을 경감할 수 있는 방법을 모색하고자 부산지역 병원들에서 시행된 년 간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고준위와 비교하여 분석함으로써 제안점을 도출하고자 하였다. 이를 위하여 부산시내에 설치된 CT 장비 중 소아 두부 CT 검사를 시행하며, 선량보고서를 PACS로 전송하는 24개 병원 28대 CT 장비를 대상으로 하여 소아 두부 CT 검사를 의뢰받은 10세 미만의 소아 2,043명을 후향적으로 조사하였다. 결과적으로 전체병원의 소아 두부 CT의 선량지표 CTDIvol의 평균값은 31.18 mGy, DLP는 $444.73mGy{\cdot}cm$로 나타나 진단참고준위를 초과하는 것으로 나타났다. 연령이 낮을수록 방사선에 대한 관리가 더욱 필요하다고 할 수 있는데 연구결과 6-10세 이하의 연령에 비해 더 낮은 다른 두 연령별에서 진단참고준위를 초과하는 환자수와 초과되는 비율이 높게 나타났다. 따라서 불필요한 방사선 노출을 줄이고 선량관리를 위한 노력들이 필요하다. 이를 위해 본 연구에서는 진단참고준위를 벗어나는 선량의 정도를 파악하고 초과되는 선량지표의 원인을 분석하여 선량감소를 위한 방안을 마련하고자 한다.