Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction (PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성)

  • Choi, Sung-Wook;Choi, Choon-Ki;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • Purpose: There have been something difficulties in locating focuses and quantitative analysis in case of pediatric patients because of the relatively small body compared to adults. This author of this study, therefore, evaluated the usefulness of DFOV (Display Field Of View) according to its changes in PET/CT image reconstruction by means of the phantom experiment and pediatric patients examination. Materials & Methods: 0.023 MBq/cc of $^{18}F$-FDG was put into the uniform NU2-94 phantom, and then emission scan was acquired for 10 minutes. For reconstruction, DFOV values were changed to 50, 45, 40, 35, 30, and 25 cm respectively. As for patient images, 20 patients who were diagnosed as the one or suspicion of the children tumor are targeted from Oct 2007 to Jan 2008. For image reconstruction, 50 cm was the basis of DFOV, and the value was adjusted to DFOV 45 cm to 25 cm respectively. In the phantom and the reconstruction image of pediatric patients, the changes in pixel size and $SUV_{max}$ according to DFOV changes were analyzed. Results: As DFOV decreased to 50, 45, 40, 35, 30, and 25 cm by means of the phantom, the pixel size was changed to 3.906, 3.515, 3.125, 2.734, 2.343, and 1.953 mm respectively. Besides, as a result of reconstruction DFOV in images of pediatric patients to 50, to 25 cm, the different values of $SUV_{max}$ are shown as 3.3, 7.3, 12, 14, 18% and 2.6, 4.3, 5.0, 7.0, 10.0% on respectively when 50 cm was the standard. Conclusion: In $SUV_{max}$ using the phantom, as DFOV decreased every 5 cm, the mean value gradually increased. With 50 cm as the standard, the increase rates were 3.7, 6.5, 11.2, 19.5, and 32.1% respectively. As for pediatric patients image too, as DFOV decreased, the rates increased as in the phantom experiment. In image reconstruction, since DFOV decrease regardless of matrix size change reduced the pixel size, the image quality can be improved. This would be more useful than reconstruction and enlarge images of pediatric patients in the same way of examining adults. However, when the value of 35 cm DFOV was applied, this may result in truncated artifact, and thus the application should be properly controlled. Change of DFOV may produce better image for pediatric patients, but changes of SUV values according to DFOV change should be considered in reading.

  • PDF

Diagnostic Efficacy of FDG-PET in Solitary Pulmonary Nodule (고립성폐결절에서 FDG-PET의 진단적 유용성)

  • Kim, Woo-Jin;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1263-1270
    • /
    • 1997
  • Background : Differentiation of malignity and benignity is crucial for management of solitary pulmonary nodule(SPN). Clinical parameters such as patient's age, nodule size, smoking history, doubling time, typical calcification in X-ray and CT findings have been reported as helpful in this purpose. However, in most cases, these parameters are not conclusive. Glucose metabolism is increased in cancer tissues including lung cancer tissues. After uptake of 2-[F-18]-fluoro-2-deoxy-D-glucose(FDG), the glucose analogue, by cancer cell, FDG is trapped in the cell without further metabolism after phosphorylation. Thus, hypermetabolic focus in FDG-positron emission tomography (PET) imaging suggest malignancy. We evaluated the diagnostic efficacy of FDG-PET imaging in distinguishing malignant and benign SPN. Methods : We evaluated 28 patients with SPN from Jan. 1995 to Jan. 1997. CT scan of chest and whole-body FDG-PET imaging were performed in all patients. Histologic diagnosis was confirmed by transthoracic fine needle aspiration and biopsy, bronchoscopic biopsy and open thoracotomy. Results : Of the 28 SPN's, 22 nodules were malignant and 6 nodules were benign. FDG-PET imaging diagnosed all malignant nodules correctly as positive, and diagnosed 4 of 6 benign nodules correctly as negative. One tuberculous granuloma and one aspergilloma showed hypennetabolic focus and were diagnosed falsely positve with FDG-PET imaging. In the diagnosis of SPN with FDG-PET, sensitivity and specificity were 100% and 66.7%, positive predictive value and negative predictive value were 92% and 100%. Conclusion : FDG-PET imaging is highly useful noninvasive diagnostic tool in distinguishing between malignant SPN and benign SPN.

  • PDF

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Diagnosis and Treatment of Brown Tumor (Brown 종양의 진단 및 치료)

  • Cho, Yong Jin;Cho, Yung Min;Na, Seung Min;Jung, Sung-Taek
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.54-61
    • /
    • 2020
  • Purpose: Brown tumor is a tumor-like disease that can occur as a linked disease of hyperparathyroidism which can causes osteoporosis, osteitis fibrosa cystica, pathologic fractures. Brown tumor has been reported as a case report, but there is no comprehensive report on the exact diagnosis and principle of management for osseous lesion. The purpose of this study is to report the treatment and results of osseous lesions through 5 cases. Materials and Methods: From February 2004 to May 2015, five cases of Brown tumor were diagnosed in Chosun University Hospital and Chonnam National University Hospital orthopedic department. Medical records and radiographs were reviewed retrospectively. Parathyroid tumors were surgically removed, and surgical treatment and observation were performed for orthopedic osseous lesions. Results: The mean length of the long axis of the symptomatic osseous lesion was 6.2 cm (4.5-9.0 cm). An average of 7.6 (range, 3 to 14) of high uptake osseous lesion showed in whole body bone scan. The absolute value, T-score and Z-score of the vertebrae and proximal femur were adequate for diagnosis of osteoporosis using dual energy X-ray absorptiometry bone mineral density at diagnosis and recovered to normal at the last follow-up. In laboratory tests, serum concentrations of total calcium, ionized calcium, inorganic phosphorus, serum alkaline phosphatase, and parathyroid hormone were helpful to diagnosis and normalized upon successful removal of parathyroid adenoma or cancer. Conclusion: For accurate diagnosis of Brown tumor, it should be accompanied by systemic examination as well as clinical symptoms, laboratory tests and radiologic examination for osseous lesions. And a good prognosis can be expected if the hyperparathyroidism is treated together with the comprehensive treatment of osseous lesions.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

National Survey of Sarcoidosis in Korea (유육종증 전국실태조사)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.453-473
    • /
    • 1992
  • Background: National survey was performed to estimate the incidence of sarcoidosis in Korea. The clinical data of confirmed cases were analysed for the practice of primary care physicians and pulmonary specialists. Methods: The period of study was from January 1991 to December 1992. Data were retrospectively collected by correspondence with physicians in departments of internal medicine, dermatology, ophthalmology and neurology of the hospitals having more than 100 beds using returning postcards. In confirmed and suspicious cases of sardoidosis, case record chart for clinical and laboratory findings were obtained in detail. Results: 1) Postcards were sent to 523 departments in 213 hospitals. Internal medicine composed 41%, dermatology 20%, ophthalmology 20% and neurology 19%. 2) Postcards were returned from 241 departments (replying rates was 48%). 3) There were 113 confirmed cases from 50 departments and 10 cases. The cases were composed from internal medicine (81%), dermatology (13%), ophthalmology (3%) and neurology (3%). 78 confirmed cases were analysed, which were composed from department of internal medicine (92%), dermatology (5%), and neurology (3%). 4) The time span for analysed cases was 1980 to 1992. one case was analysed in 1980 and the number gradually increased to 18 cases in 1991. 5) The majority of patients (84.4%) were in the age group of 20 to 49 years. 6) The ratio of male to female was 1 : 1.5. 7) The most common chief complains were respiratory symptoms, dermatologic symptoms, generalized discomforts, visual changes, arthralgia, abdominal pains, and swallowing difficulties in order. 16% of the patients were asymptomatic. 8) Mean duration between symptom onset and diagnosis was 2 months. 9) The most common symptoms were respiratory, general, dermatologic, ophthalmologic, neurologic and cardiac origin in order. 10) Hemoglobin, hematocrits and platelet were in normal range. 58% of the patients had lymphopenia measuring less than 30% of white cell count. The ratio of CD4 to CD8 lymphocytes was $1.73{\pm}1.16$ with range of 0.43 to 4.62. ESR was elevated in 43% of the cases. 11) Blood chemistry was normal in most cases. Serum angiotensin converting enzyme (S-ACE) was $66.8{\pm}58.6\;U/L$ with the range of 8.79 to 265 U /L. Proteinuria of more than 150 mg was found in 42. 9% of the patients. 12) Serum IgG was elevated in 43.5%, IgA in 45.5%, IgM in 59.1% and IgE in 46.7%. The levels of complement C3 and C4 were in the normal range. Anti-nuclear antibody was detected in 11% of the cases. Kweim test was performed in 3 cases, and in all cases the result was positive. 13) FVC was decreased in 17.3%, FEV1 in 11.5%, FEV1/FVC in 10%, TLC in 15.2%, and DLco in 64.7%. 14) PaO2 was decreased below 90 mmHg in 48.6% and PaCO2 was increased above 45 mmHg in 5.7%. 15) The percentage of macrophages in BAL fluid was $51.4{\pm}19.2%$, lymphocytes $44.4{\pm}21.1%$, and the ratio of CD4 to CD8 lymphocytes was $3.41{\pm}2.07$. 16) There was no difference in laboratory findings between male and female. 17) Hilar enlargement on chest PA was present in 87.9% (bilaterally in 78.8% and unilaterally in 9.1%). 18) According to Siltzbach's classification, stage 0 was 5%, stage 158.3%, stage 228.3%, and stage 38.3%. 19) Hilart enlargement on chest CT was present in 92.6% (bilaterally 76.4% and unilaterally in 16.2%). 20) HRCT was done in 16 cases. The most common findings were nodules, interlobular thickening, focal patchy infiltrations in order. Two cases was normal finding. 21) Other radiologic examinations showed bone change in one case and splenomegaly in two cases. 22) Gallium scan was done in 12 cases. Radioactivity was increased in hilar and mediastinal lymph nodes in 8 cases and in parenchyme in 2 cases. 23) The pathologic diagnosis was commonly performed by transbrochial lung biopsy (TBLB, 47.3%), skin and mediastinal lymph nodes biopsy (34.5%), peripheral lymph nodes biopsy (23.6%), open lung biopsy (18.2%) and bronchial biopsy in order. 24) The most common findings in pathology were non·caseating granuloma (100%), multi-nucleated giant cell (47.3%), hyalinized acellular scar (34.5%), reticulin fibrin network (20%), inclusion body (10.9%), necrosis (9.1%), and lymphangitic distribution of granuloma (1.8%) in order. Conclusion: Clinical, laboratory, radiologic and pathologic findings were summarized. This collected data will assist in finding a test for detection and staging of sarcoidosis in Korea in near future.

  • PDF