• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.022 seconds

Development of a Representative Model for Different Body Shapes of 18-24 Aged Women - An Application of a 3D Morphing Technique - (3차원 모핑기법에 의한 18-24세 여성의 체형별 대표 형상 도출을 위한 연구)

  • Shin, Ju-Young;Choi, Young-Lim;Nam, Yun-Ja
    • The Korean Fashion and Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.590-599
    • /
    • 2011
  • The purpose of this study is to classify body types into different groups based on 3D scanned data, and identify the representative body shapes that most frequently appear in the groups. A high frequency range was defined based on body measurement data, and representative shapes were identified based on body scan data of women aged 18-24. The major findings of this study are as follows. First, the three typical types of height, bust and drop mixes among Korean women aged 18-24 are as follows:) 155-88-N,) 160-82-A, and 165-85-A. Regarding the body type, the A and N types frequently appeared, while the H type was rare. Second, among the subjects of the high-frequency groups, upright bodies were selected as sample models and were used for morphing. An adjustment was made to the morphing results to reflect the body characteristics of the sample models evenly. Third, to verify the morphing results, the body sizes of the sample models and the created models were compared. The result showed that, the sizes were close to the average size of the sample models. Fourth, to verify whether the morphing processes adequately reflected the features of the body shapes, cross-section models of key body parts were made and the degree of representativeness was determined.

Hidden Object Detection System using Parametric Array (파라메트릭 배열을 이용한 은폐 물체 탐지 시스템)

  • Lee, Kibae;Lee, Jaeil;Bae, Jinho;Lee, Chong Hyun;Cho, Jung Hong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.78-86
    • /
    • 2017
  • In this paper, we propose hidden object detection system using parametric array based on acoustic signal that is harmless to human body. A transmit signal of the proposed detection system uses a high directive chirp signal generated from parametric array phenomenon, which uses technique to improve a signal to noise (SNR) of a received signal and a distance resolution trough the dechirp processing. The transmit sensor array is constructed as $8{\times}2$ and has a horizontal beam width of $7^{\circ}$ and vertical beam width of $26^{\circ}$. To verify the detection and visualization of the proposed system, a 2-axis driving control system based on linear stage was constructed, and A-scan, B-scan, and C-scan experiments was addressed for hidden object. From experimental results, we detected and visualized the hidden bronze plate and pipe by cloth and the visualized shapes was confirmed. Especially, the obtained errors was $0.015m^2$ for bronze plate, and $0.046m^2$ for pipe.

Interpolation and Parametrization of Human Body Scan Data Using B-Spline Surface (B-Spline Surface를 이용한 인체 계측 데이터의 Interpolation과 Parametrization)

  • 설인환;강태진
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.235-238
    • /
    • 2002
  • 3차원 어패럴 캐드 시스템은 의복 생산 공정의 자동화를 위해 꾸준히 연구되고 있다. 이러한 어패럴 캐드 시스템의 주요한 목표 중의 하나가 소량 주문 생산에의 대응이다. 그런데 인체의 형태는 매우 다양하므로 개개인의 인체 형태에 대응하는 적합한 의복 디자인을 위해서는 먼저 정확한 인체 형태의 정확한 계측이 필요하다. 인체 데이터의 3차원적인 제품들인 계측은 그동안 많은 연구가 이루어져 상업화된 제품도 다수 출시되었다. (중략)

  • PDF

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.8 no.2
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

A Comparative Study on Virtual Try-on Systems using Body Measurement Input

  • Lim, Ho-Sun;Istook, Cynthia
    • The International Journal of Costume Culture
    • /
    • v.13 no.2
    • /
    • pp.118-129
    • /
    • 2010
  • Digital technology introduced into the clothing and fashion industry is evolving to digital virtual fashions and consumer-centered mass-customized production systems. Today the application of such 3D virtual try-on systems is being expanded gradually in the clothing industry. This study purposed to make virtual avatars and virtual garments using OptiTex and V-stitcher virtual software and compared the appearance of the virtual garments put on the virtual avatars. For this, we created virtual avatars and virtual garments using body measurements obtained from jive subjects of top jive body shapes, respectively, using $[TC]^2$ body scanner. According to the results of comparing the outcomes of the two different virtual software systems, virtual avatar II of V-Stitcher tended to have a more round and lifted hip and the waist line at a higher position. In addition, the body curves and shapes of a virtual avatar affect the appearance of virtual garments. This study applied the same body measurements to virtual avatars and the same pattern to virtual garments, but when different kinds of virtual software were used, the virtual avatars and virtual garments showed different appearance and fit. This result may mean that when customers buy apparel products using different kinds of virtual try-on systems, their evaluation of appearance can vary depending on the virtual try-on system. Therefore, research needs to be made actively for the development and use of linkage programs that can reflect actual body measurements between virtual software systems and 3D body scanning systems.

  • PDF

Direct Clothing Pattern Development from the 3D Illustration on the Personal Human Body Model (인체모델과 3차원 일러스트레이션을 이용한 의복패턴개발)

  • Park, Hye-Jun;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.2
    • /
    • pp.340-347
    • /
    • 2008
  • A prototype of 3D clothing design system with a direct pattern development function was suggested, reflecting intuitive design functions and design modifications while considering the fit of clothing patterns with the 3D human body in the virtual 3D space. The research method was as follows. Clothing models were created using a 3D design tool, 3ds max on the surface of 3D human body model made by scanning an actual human body. 3D illustrations were completed by revising the fit and sizing of the human body and clothing models. 2D T-shirt pattern was produced 3D illustrations using from a 3D scanning data modeling solution RapidForm 2004, a 2D conversion program for 3D data called 2C-AN, and Yuka CAD. As a result, the following conclusions were made. The fit of the clothing and human body can be adjusted by reflecting individual body figure characteristics and 3D illustrations over the actual 3D body model. Furthermore, intuitive design support functions were intensified overcoming the weak point of existing 3D clothing design system by developing the direct clothing design in the virtual 3D space. 3D illustration design modifications can be directly reflected on clothing patterns from 3D illustrations by 3D clothing design system developed in this study.

Avascular Necrosis of Bone after Renal Transplantation - Prevalence and Usefulness of Bone SPECT - (신장 이식후에 발생한 무혈관성 골괴사 -발생 빈도 및 골 SPECT의 유용성에 관하여 -)

  • Choi, Yun-Young;Yang, Seoung-Oh;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.504-510
    • /
    • 1995
  • Avascular necrosis(AVN) of bone can be resulted from various causes that distrub vascular supply to bone tissue, including steroid therapy after renal transplantation. In this study, we determine the prevalence of the avascular necrosis of bone after renal transplantation and compare the role of the bone scan, SPECT and MRI. In 301 patients with transplanted kidney, the prevalence of avascular necrosis was deter-mined clinically. Site of bone necrosis was evaluated by clinical symptom, bone scan, SPECT and MRI. Bone scan was done in all patients with AVN. Bone SPECT and MRI were done in six cases; and MRI was done in two cases. The prevalence of AVN was 3.3% (10/301), and the site of AVN was 16 femoral heads in 10 patients (bilateral: 60%) and bilateral calcaneal tuberosity in one patient. Bone scan showed typical AVN (cold area with surrounding hot uptake) in 13 lesions, only hot uptake in three lesions (including two calcaneal tuberosities), decreased uptake in one lesion, and normal in one lesion. Decreased uptake and normal lesion showed an equivacal cold area without surrounding hot uptake on SPECT. A symptomatic patient with positive bone SPECT showed normal finding on MRI. The prevalence of AVN of bone after renal transplantation was 3.3%, and whole body bone scan showed multiple bone involvement. Two symptomatic hip Joints without definite lesion on whole body bone scan or MRI showed cold defect on SPECT. Therefore, we conclude that bone SPECT should be perfomed in a symptomatic patient with negative bone scan or MRI in case with high risk of AVN after renal transplantation.

  • PDF

A Study on Body Silhouette Change by Wearing English Women's Upper Garments of the Late $19^{th}$ Century (19세기 후반 영국 여성복 상의 착용에 따른 인체 실루엣 변화)

  • Cha, Joo-Eun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1205-1220
    • /
    • 2011
  • The purpose of this study is to verify the change of body posture by putting on the late $19^{th}$ century English women's bodice or waistcoat. This study analyzed the female somatotype which puts on upper garments of Victorian era with using 3D body scan technology. Two sets of $19^{th}$ century women's bodice and waistcoat patterns were developed with the $19^{th}$ century model size and those patterns were used for making the experimental garments. The fit of experimental garments was evaluated by the degree of change with posture and waist measurements. Three women with the same waist girth measurements with the model size were participated to the fitting test. The postural change was measured from cross-sectional body diagrams. The result of this study showed that the waist measurement of the late $19^{th}$ century English women's bodice and waistcoat pattern was smaller than the waist girth measurement. These garments compressed the midriff of the body and it made women's distinct body silhouette. The waist girth measurement of 1876 bodice pattern was 9.2cm smaller than presented model size. The subjects' waist girth measurements were shortened by 5.0~6.1cm after wearing the 1876 bodice garment. The waist girth measurement of 1880 waistcoat pattern was 7.1cm smaller than presented model size. The subjects' waist girth measurements were shortened by 2.7~3.7cm after wearing the 1880 waistcoat garment. The back side parts of their waist were compressed and their postures were changed. The neck and shoulders were moved forward after wearing the experimental garments. These results showed that body posture could be changed to "S" shape silhouette as wearing the late $19^{th}$ century English women's bodice or waistcoat.

Classification of Torso Shapes of Men Aged 40-64 - Based on Measurements Extracted from the 8th Size Korea Scans - (40-64세 남성의 토르소 형태 분류에 관한 연구 - 제8차 Size Korea 인체형상으로부터 추출한 측정값을 이용하여 -)

  • Guo Tingyu;Eun Joo Ryu;Hwa Kyung Song
    • The Korean Fashion and Textile Research Journal
    • /
    • v.25 no.1
    • /
    • pp.92-103
    • /
    • 2023
  • As the body shape change which occurs after middle age is the main factor affecting the fit of ready-to-wear clothes, this study was designed to classify and analyze the torso shapes of middle-aged men. This study sorted 3D body scans of 200 men aged 40-64 from the 8th Size Korea (2021) database and extracted their 47 measurement values using the Grasshopper algorithm for automatic extraction landmarks and measurements, developed by the previous research (Ryu & Song, 2022). Eight principal components (torso length, shoulder size, overall body size, abdomen prominence, back protrusion, neck inclination, upper body slope, and hip prominence) were identified and four torso shapes were classified. Shape 1 (28.5%) exhibited the shortest torso length, the narrowest shoulders, and the most protruding back. Shape 2 (21.0%) exhibited the skinniest body and the largest backward inclination of the upper body. Hence, the back appeared to be protruding, and the abdomen looked prominent. Shape 3 (25.5%) had the largest overall body size. Thus, the abdomen looked the least protruding, and it exhibited the flattest back. Shape 4 (25.0%) had the longest torso, widest shoulders, straightest neck, and the least protruding hips. This study suggested these three discriminant functions to identify a new person's torso type.

Three‐Dimensional Automatic Measurement Extraction Algorithms for Neck‐base Part of Females in Their Twenties (20대 여성의 목밑둘레 부위에 대한 3차원 자동 측정 알고리즘)

  • Hwang, Keun-Young;Nam, Yun-Ja;Park, Jae-Kyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • The purpose of this study is to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional human scan data. So we developed the algorithms for automatic identification of landmarks related to the neck-base types. The subjects were 58 women $18{\sim}24$ years of age. Their body were measured directly and indirectly by using camera and three-dimensional body scanner. They were measured during the months of October in 2001. Based on the characters of classified neck-base types, algorithms for the automatic identification of landmarks and methods of automatic measurement are developed. The three-dimensional automatic measuring program is made by $C^{++}$ language. Using this program, 4 landmarks are identified and 6 items are measured. In the verifying the precision of automatic measurement, the height measurements(cervicale, side neck point, front neck point) were relatively accurate, but neck-base width measurement was measured wide.